{"title":"Fluke Insulation Testers","description":"\u003cp\u003eFluke insulation testers check the insulation resistance of cables, motors and switchgear, from the 1000V 1503 and 1507 to the 2500V 1535 and 1537 and the 1577 and 1587 insulation multimeters. Every tester we sell is genuine Fluke with full manufacturer warranty. Enjoy competitive pricing and fast delivery across Malaysia, with same-day delivery for Klang Valley customers.\u003c\/p\u003e","products":[{"product_id":"fluke-1535-2500v-insulation-resistance-meter-digital-high-voltage-meg","title":"Fluke 1535 High Voltage Insulation Tester 2500V","description":"\u003cstyle\u003e \/* Scoped styles for the product description *\/ .product-description { font-family: Arial, sans-serif; line-height: 1.6; } .product-description .highlight { color: #6633ff; font-weight: bold; } .product-description .offer { color: #e74c3c; font-weight: bold; } .product-description table { width: 100%; border-collapse: collapse; margin: 20px 0; } .product-description table, .product-description th, .product-description td { border: 1px solid #ddd; } .product-description th, .product-description td { padding: 8px; text-align: left; } .product-description th { background-color: #f4f4f4; } .product-description .section-title { color: #333; margin-top: 20px; } \u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 1535 Insulation Resistance Tester\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 1535 2500V Insulation Resistance Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 1535 2500V Insulation Resistance Meter\u003c\/strong\u003e is a high-precision tool designed for safe and accurate insulation testing in electrical systems. It measures insulation resistance up to 2500 V, helping electricians and maintenance professionals detect potential insulation failures in cables, transformers, and motors before they cause downtime or damage. Compact and reliable, the \u003cstrong\u003eFLUKE 1535 2500V Insulation Resistance Meter\u003c\/strong\u003e is suitable for industrial, commercial, and field applications.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable test voltages: \u003cstrong\u003e250 V, 500 V, 1000 V, and 2500 V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to \u003cstrong\u003e500 GΩ\u003c\/strong\u003e for thorough analysis.\u003c\/li\u003e\n\u003cli\u003eAutomatic \u003cstrong\u003ePolarization Index (PI)\u003c\/strong\u003e and \u003cstrong\u003eDielectric Absorption Ratio (DAR)\u003c\/strong\u003e calculations to minimize environmental influence.\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong\u003e1,300 measurements\u003c\/strong\u003e at 2,500 V on a single charge.\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V rating for enhanced operator safety.\u003c\/li\u003e\n\u003cli\u003eShort circuit current of \u0026gt;2 mA for stable resistance measurements.\u003c\/li\u003e\n\u003cli\u003eBuilt-in warning for energized circuits above 30 V.\u003c\/li\u003e\n\u003cli\u003eDurable, portable design for field and factory floor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1535 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003e8 AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e73.5 mm x 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e8 AA alkaline cells, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e184 mm x 211 mm x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e≤80 % RH (10 °C to 30 °C), ≤50 % RH (30 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 2000 m; Storage: 12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529 IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInsulation Resistance Testing:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Voltage\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Measurement:\u003c\/strong\u003e 1 nA to 2 mA, ±20% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Measurement:\u003c\/strong\u003e 0.01 μF to 2.00 μF, ±15% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarning Range for Energized Circuits:\u003c\/strong\u003e \u0026gt;30 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e \u0026gt;2 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWarranty Information:\u003c\/h2\u003e\n\u003cp\u003e1 Year Warranty\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":42997985312980,"sku":"FK 1535\/APAC","price":9154.7,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/f6a95b8d6de409f2411fe683e778655d.jpg?v=1769185319"},{"product_id":"fluke-1537-2500v-insulation-resistance-meter-digital-high-voltage-meg","title":"Fluke 1537 High Voltage Insulation Tester 2500V","description":"\u003cstyle\u003e \/* Scoped styles for the product description *\/ .product-description { font-family: Arial, sans-serif; line-height: 1.6; } .product-description .highlight { color: #6633ff; font-weight: bold; } .product-description .offer { color: #e74c3c; font-weight: bold; } .product-description table { width: 100%; border-collapse: collapse; margin: 20px 0; } .product-description table, .product-description th, .product-description td { border: 1px solid #ddd; } .product-description th, .product-description td { padding: 8px; text-align: left; } .product-description th { background-color: #f4f4f4; } .product-description .section-title { color: #333; margin-top: 20px; } \u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 1537 Insulation Resistance Tester\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e is a high-voltage testing tool designed for precise insulation resistance measurements in electrical systems. It allows maintenance professionals and electricians to verify the integrity of insulation on cables, transformers, and motors. With a testing voltage up to 2500 V, the \u003cstrong\u003eFLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e ensures safety and reliability while identifying potential insulation failures before they cause operational issues.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features of FLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable test voltages: \u003cstrong\u003e250 V, 500 V, 1000 V, and 2500 V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to \u003cstrong\u003e500 GΩ\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of \u003cstrong\u003ePI\u003c\/strong\u003e, \u003cstrong\u003eDAR\u003c\/strong\u003e, and \u003cstrong\u003eDielectric Discharge (DD)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFine-tunable test voltages in \u003cstrong\u003e100 V increments\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V rating for enhanced safety.\u003c\/li\u003e\n\u003cli\u003eShort circuit current of \u003cstrong\u003e\u0026gt;5 mA\u003c\/strong\u003e for rapid, stable resistance measurements.\u003c\/li\u003e\n\u003cli\u003eRamp Test Mode: Linearly increase test voltage to pinpoint faults.\u003c\/li\u003e\n\u003cli\u003eBuilt-in timer for controlled testing up to \u003cstrong\u003e99 minutes\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eExtensive data management: Store and review results or transfer data via PC software.\u003c\/li\u003e\n\u003cli\u003eVisual and audio continuity indicators for efficient troubleshooting.\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong\u003e1,300 tests\u003c\/strong\u003e at 2500 V or \u003cstrong\u003e6,500 tests\u003c\/strong\u003e at 250 V on a single charge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1537 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003e8 AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003ePC Software for Data Management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e73.5 mm x 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e8 AA alkaline cells, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e184 mm x 211 mm x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e≤80 % RH (10 °C to 30 °C), ≤50 % RH (30 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 2000 m; Storage: 12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529 IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInsulation Resistance Testing:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Voltage\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Measurement:\u003c\/strong\u003e 1 nA to 2 mA, ±20% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Measurement:\u003c\/strong\u003e 0.01 μF to 2.00 μF, ±15% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarning Range for Energized Circuits:\u003c\/strong\u003e \u0026gt;30 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e \u0026gt;5 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimer Range:\u003c\/strong\u003e 0 to 99 minutes, adjustable in 1-minute intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage Measurement:\u003c\/strong\u003e Up to 600 V (±2% accuracy).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Measurement:\u003c\/strong\u003e Up to 60.00 kΩ (±2% accuracy).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWarranty Information:\u003c\/h2\u003e\n\u003cp\u003e1 Year Warranty\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":42997986525396,"sku":"FK 1537\/APAC","price":12474.3,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/c5147250aa6919262a4524145085778f.jpg?v=1769185352"},{"product_id":"fluke-1503-insulation-resistance-tester","title":"Fluke 1503 Insulation Resistance Tester 1000V | CAT IV 600V 2000MΩ Earth Bond","description":"\u003cstyle\u003e \/* Scoped styles for the product description *\/ .product-description { font-family: Arial, sans-serif; line-height: 1.6; } .product-description .highlight { color: #6633ff; font-weight: bold; } .product-description .offer { color: #e74c3c; font-weight: bold; } .product-description table { width: 100%; border-collapse: collapse; margin: 20px 0; } .product-description table, .product-description th, .product-description td { border: 1px solid #ddd; } .product-description th, .product-description td { padding: 8px; text-align: left; } .product-description th { background-color: #f4f4f4; } .product-description .section-title { color: #333; margin-top: 20px; } \u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1 dir=\"ltr\"\u003e\u003cstrong\u003eFluke 1503 Insulation Resistance Tester — 1000V | 2000MΩ | CAT IV 600V | Earth Bond\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFluke 1503 Insulation Resistance Tester\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a reliable, easy-to-use insulation tester designed for electricians, maintenance engineers and electrical contractors. Supporting test voltages of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e500V and 1000V\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with insulation resistance measurement up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2000MΩ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the Fluke 1503 is ideal for testing motors, cables, switchgear and \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003einstallations to \u003c\/span\u003e\u003cspan\u003eensure system safety \u003c\/span\u003e\u003cspan\u003eand compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eFluke 1503 Insulation Resistance Meter x1\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP74 Test Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips — Red (PN 1958654) \u0026amp; Black (PN 1958646)\u003c\/li\u003e\n\u003cli\u003eRemote Test Probe\u003c\/li\u003e\n\u003cli\u003eProtective Holster\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003eFour AA Alkaline Batteries (NEDA 15A \/ IEC LR6)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ch2 dir=\"ltr\"\u003eAC\/DC Voltage Measurement\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (50Hz to 400Hz) ±(% of Rdg + Digits)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3MΩ (nominal), \u0026lt;100pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection Ratio (1kΩ unbalanced)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60dB at DC, 50 or 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eEarth Bond Resistance Measurement\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eRange\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20.00Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0Ω\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000Ω\u003c\/td\u003e\n\u003ctd\u003e1.0Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Circuit Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;4.0V, \u0026lt;8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;200.0mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eInsulation Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01MΩ to 2000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+20%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Discharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDischarge time \u0026lt;0.5 second for C = 1μF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLive Circuit Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInhibit test if terminal voltage \u0026gt;30V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Capacitive Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperable with up to 1μF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cstrong\u003eMeasure Accuracy:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTest Voltage\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e500V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5%+5) to 2000MΩ; ±(10%+3) above 2000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eGeneral Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage at Any Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt;18°C or \u0026gt;28°C (\u0026lt;64°F or \u0026gt;82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRandom, 2g, 5-500Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 metre drop per IEC 61010-1 2nd Edition — 6 sides, oak floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectromagnetic Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIn RF field of 3V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TÜV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (H x W x L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 x 10.0 x 20.3cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-Range Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cstrong\u003eAltitude:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000m CAT IV 600V \/ 3000m CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Operating (Storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eUsage\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Test Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt least 1000 insulation tests with fresh alkaline batteries at room temperature. Standard tests of 1000V into 1MΩ with duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. Standard tests of 1Ω with duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003col\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003e500V \u0026amp; 1000V Test Voltages — 0.01MΩ to 2000MΩ Range\u003c\/strong\u003e\u003cbr\u003eTwo selectable test voltages with insulation resistance measurement up to 2000MΩ cover motor, cable, switchgear and electrical installation testing requirements.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eEarth Bond Continuity — \u0026gt;200mA Short Circuit Current\u003c\/strong\u003e\u003cbr\u003eEarth bond continuity with \u0026gt;200.0mA short circuit current across four resistance ranges supports low-resistance earth bond testing for electrical safety compliance.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eAuto-Discharge in Under 0.5 Seconds\u003c\/strong\u003e\u003cbr\u003eAutomatically discharges capacitive voltage after insulation testing in under 0.5 seconds for capacitive loads up to 1μF — protecting operators from residual voltage hazards.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eLive Circuit Indicator — Test Inhibit Above 30V\u003c\/strong\u003e\u003cbr\u003eAutomatically inhibits insulation testing if terminal voltage exceeds 30V before test initialisation — preventing accidental testing on energised circuits.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eRemote Test Probe\u003c\/strong\u003e\u003cbr\u003eIncluded remote test probe simplifies repetitive insulation testing — trigger tests from the probe end for faster field workflows.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eCAT IV 600V Safety — CSA \u0026amp; TÜV Certified\u003c\/strong\u003e\u003cbr\u003eComplies with ANSI\/ISA 82.02.01, CAN\/CSA-C22.2 No. 61010-1-04 and IEC\/EN 61010-1 CAT IV 600V, certified by both CSA and TÜV.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003e1000+ Insulation Test Battery Life\u003c\/strong\u003e\u003cbr\u003eFour AA alkaline batteries support at least 1000 insulation tests and 2500 earth bond measurements per set.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 dir=\"ltr\"\u003eApplications\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMotor insulation resistance testing\u003c\/li\u003e\n\u003cli\u003eCable and wiring insulation verification\u003c\/li\u003e\n\u003cli\u003eSwitchgear and distribution board testing\u003c\/li\u003e\n\u003cli\u003eElectrical installation commissioning\u003c\/li\u003e\n\u003cli\u003eEarth bond continuity verification\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance insulation surveys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003eWhy Choose Fluke 1503?\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e500V and 1000V test voltages for flexible insulation testing\u003c\/li\u003e\n\u003cli\u003eWide 0.01MΩ to 2000MΩ insulation resistance range\u003c\/li\u003e\n\u003cli\u003eEarth bond \u0026gt;200mA short circuit current\u003c\/li\u003e\n\u003cli\u003eAuto-discharge \u0026lt;0.5 seconds for post-test safety\u003c\/li\u003e\n\u003cli\u003eLive circuit inhibit protection above 30V\u003c\/li\u003e\n\u003cli\u003eCAT IV 600V — CSA and TÜV certified\u003c\/li\u003e\n\u003cli\u003e1000+ insulation tests per battery set\u003c\/li\u003e\n\u003cli\u003eTrusted Fluke professional instrument quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000092819668,"sku":"FK 1503","price":5400.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke_1503_01.jpg?v=1788336673"},{"product_id":"fluke-1507-insulation-tester-1","title":"Fluke 1507 Insulation Resistance Tester | 50V to 1000V","description":"\u003cstyle\u003e\n    \/* Scoped styles for the product description *\/\n    .product-description {\n        font-family: Arial, sans-serif;\n        line-height: 1.6;\n    }\n\n    .product-description .highlight {\n        color: #6633ff;\n        font-weight: bold;\n    }\n\n    .product-description .offer {\n        color: #e74c3c;\n        font-weight: bold;\n    }\n\n    .product-description table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 20px 0;\n    }\n\n    .product-description table,\n    .product-description th,\n    .product-description td {\n        border: 1px solid #ddd;\n    }\n\n    .product-description th,\n    .product-description td {\n        padding: 8px;\n        text-align: left;\n    }\n\n    .product-description th {\n        background-color: #f4f4f4;\n    }\n\n    .product-description .section-title {\n        color: #333;\n        margin-top: 20px;\n    }\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 1507 Insulation Resistance Tester\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 1507 Insulation Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 1507 Insulation Tester\u003c\/strong\u003e is a compact and reliable insulation resistance tester designed for professional electricians and maintenance technicians. It supports insulation testing voltages from 50V to 1000V, making it suitable for verifying insulation integrity in motors, cables, panels, and electrical installations. The \u003cstrong\u003eFLUKE 1507 Insulation Tester\u003c\/strong\u003e also integrates essential multimeter functions, allowing users to perform voltage, resistance, and continuity tests using a single handheld instrument.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation resistance tests from \u003cstrong\u003e0.01 MΩ to 10 GΩ\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages: \u003cstrong\u003e50 V, 100 V, 250 V, 500 V, and 1000 V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003elive circuit detection\u003c\/strong\u003e to prevent tests if voltage \u0026gt;30 V is present.\u003c\/li\u003e\n\u003cli\u003eAuto-discharge feature enhances user safety.\u003c\/li\u003e\n\u003cli\u003eMeasures \u003cstrong\u003eAC\/DC voltage\u003c\/strong\u003e from 0.1 V to 600 V.\u003c\/li\u003e\n\u003cli\u003eLow-ohm \u003cstrong\u003eearth-bond continuity\u003c\/strong\u003e (200 mA short circuit current).\u003c\/li\u003e\n\u003cli\u003eRemote test probe simplifies repetitive or hard-to-reach testing.\u003c\/li\u003e\n\u003cli\u003eAuto power-off to extend battery life.\u003c\/li\u003e\n\u003cli\u003eLarge, backlit display for easy readability.\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V overvoltage safety rating.\u003c\/li\u003e\n\u003cli\u003eCompatible with the optional \u003cstrong\u003eFluke TPAK magnetic hanging system\u003c\/strong\u003e for hands-free use.\u003c\/li\u003e\n\u003cli\u003eRuns on four AA alkaline batteries for up to \u003cstrong\u003e1000 insulation tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP74 Test Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003eRemote Test Probe\u003c\/li\u003e\n\u003cli\u003eProtective Holster\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003eFour AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAC\/DC Voltage Measurement:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e0.1 V to 600 V\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz to 400 Hz\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEarth Bond Resistance:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 Ω\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInsulation Resistance:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Voltage\u003c\/th\u003e\n\u003cth\u003eMeasurement Range\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts), ±(10% + 3 above 2000 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eFour AA Alkaline Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 insulation tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e20.3 x 10.0 x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eWarranty Information:\u003c\/h2\u003e\n\u003cp\u003e1 Year Warranty\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000098783444,"sku":"FK 1507","price":6174.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/FLUKE_1507.png?v=1769186269"},{"product_id":"fluke-1587-insulation-multimeter","title":"Fluke 1587 Insulation Multimeter | 50V–1000V, CAT IV 600V","description":"\u003cstyle\u003e \/* Scoped styles for the product description *\/ .product-description { font-family: Arial, sans-serif; line-height: 1.6; } .product-description .highlight { color: #6633ff; font-weight: bold; } .product-description .offer { color: #e74c3c; font-weight: bold; } .product-description table { width: 100%; border-collapse: collapse; margin: 20px 0; } .product-description table, .product-description th, .product-description td { border: 1px solid #ddd; } .product-description th, .product-description td { padding: 8px; text-align: left; } .product-description th { background-color: #f4f4f4; } .product-description .section-title { color: #333; margin-top: 20px; } \u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003e\n\u003cmeta charset=\"utf-8\"\u003eFluke 1587 Insulation Tester 50V–1000V Digital CAT IV, CAT III\u003c\/h1\u003e\n\u003ch2 data-start=\"433\" data-end=\"447\"\u003eOverview of Fluke 1587 Insulation Tester\u003c\/h2\u003e\n\u003cp data-start=\"449\" data-end=\"606\"\u003eThe \u003cstrong data-start=\"453\" data-end=\"467\"\u003eFluke 1587\u003c\/strong\u003e is a professional-grade digital insulation tester designed for industrial electrical maintenance, troubleshooting, and preventive testing.\u003c\/p\u003e\n\u003cp data-start=\"608\" data-end=\"824\"\u003eWith adjustable test voltages from \u003cstrong data-start=\"643\" data-end=\"659\"\u003e50V to 1000V\u003c\/strong\u003e, CAT III \/ CAT IV safety ratings, and rugged field-ready construction, this tester is suitable for motors, transformers, switchgear, cables, and industrial systems.\u003c\/p\u003e\n\u003cp data-start=\"826\" data-end=\"955\"\u003eBuilt to withstand harsh environments, it operates from \u003cstrong data-start=\"882\" data-end=\"899\"\u003e-20°C to 55°C\u003c\/strong\u003e, making it ideal for both indoor and site applications.\u003c\/p\u003e\n\u003ch2 data-start=\"962\" data-end=\"979\"\u003eKey Features of Fluke 1587 Insulation Tester\u003c\/h2\u003e\n\u003cul data-start=\"981\" data-end=\"1364\"\u003e\n\u003cli data-start=\"981\" data-end=\"1036\"\u003e\n\u003cp data-start=\"983\" data-end=\"1036\"\u003eAdjustable insulation test voltage: \u003cstrong data-start=\"1021\" data-end=\"1036\"\u003e50V – 1000V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1037\" data-end=\"1074\"\u003e\n\u003cp data-start=\"1039\" data-end=\"1074\"\u003eDigital display for clear reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1075\" data-end=\"1100\"\u003e\n\u003cp data-start=\"1077\" data-end=\"1100\"\u003eTest current: \u003cstrong data-start=\"1093\" data-end=\"1100\"\u003e1mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1101\" data-end=\"1134\"\u003e\n\u003cp data-start=\"1103\" data-end=\"1134\"\u003eCAT III \/ CAT IV safety rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1135\" data-end=\"1173\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1173\"\u003eSafety category voltage: \u003cstrong data-start=\"1164\" data-end=\"1173\"\u003e1000V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1174\" data-end=\"1195\"\u003e\n\u003cp data-start=\"1176\" data-end=\"1195\"\u003eCSA \u0026amp; CE approved\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1196\" data-end=\"1239\"\u003e\n\u003cp data-start=\"1198\" data-end=\"1239\"\u003eLong battery life: \u003cstrong data-start=\"1219\" data-end=\"1239\"\u003eup to 1000 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1267\"\u003e\n\u003cp data-start=\"1242\" data-end=\"1267\"\u003ePowered by AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1268\" data-end=\"1320\"\u003e\n\u003cp data-start=\"1270\" data-end=\"1320\"\u003eWide operating temperature range (-20°C to 55°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1321\" data-end=\"1364\"\u003e\n\u003cp data-start=\"1323\" data-end=\"1364\"\u003eCompact \u0026amp; lightweight industrial design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Datasheet of Fluke 1587 Insulation Tester\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFluke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e1587\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInsulation Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester Type\u003c\/td\u003e\n\u003ctd\u003eInsulation Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Test Voltage\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category Level\u003c\/td\u003e\n\u003ctd\u003eCAT III, CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category Voltage\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards \/ Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e1000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temp\u003c\/td\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temp\u003c\/td\u003e\n\u003ctd\u003e55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e624 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Fluke 1587 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2256\" data-start=\"2236\"\u003eWarranty Terms\u003c\/h2\u003e\n\u003cul data-end=\"2425\" data-start=\"2258\"\u003e\n\u003cli data-end=\"2318\" data-start=\"2284\"\u003e\n\u003cp data-end=\"2318\" data-start=\"2286\"\u003eCome with 12 month(s) of supplier warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2356\" data-start=\"2319\"\u003e\n\u003cp data-end=\"2356\" data-start=\"2321\"\u003eCovers manufacturing defects only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2425\" data-start=\"2357\"\u003e\n\u003cp data-end=\"2425\" data-start=\"2359\"\u003eExcludes misuse, accidental damage, modification, or consumables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2460\" data-start=\"2432\"\u003e💡 Why Choose Fluke 1587?\u003c\/h2\u003e\n\u003ch3 data-end=\"2500\" data-start=\"2462\"\u003e1️⃣ Industrial Safety Compliance\u003c\/h3\u003e\n\u003cp data-end=\"2595\" data-start=\"2501\"\u003eCAT III \u0026amp; CAT IV safety rating up to 1000V ensures safe operation in high-energy environments.\u003c\/p\u003e\n\u003ch3 data-end=\"2631\" data-start=\"2597\"\u003e2️⃣ Wide Voltage Flexibility\u003c\/h3\u003e\n\u003cp data-end=\"2729\" data-start=\"2632\"\u003eTest insulation from 50V to 1000V — suitable for low-voltage controls up to industrial equipment.\u003c\/p\u003e\n\u003ch3 data-end=\"2765\" data-start=\"2731\"\u003e3️⃣ Long Battery Performance\u003c\/h3\u003e\n\u003cp data-end=\"2843\" data-start=\"2766\"\u003eUp to 1000 hours battery life reduces downtime and maintenance interruptions.\u003c\/p\u003e\n\u003ch3 data-end=\"2881\" data-start=\"2845\"\u003e4️⃣ Built for Tough Conditions\u003c\/h3\u003e\n\u003cp data-end=\"2958\" data-start=\"2882\"\u003eOperates from -20°C to 55°C — suitable for factory floors and outdoor sites.\u003c\/p\u003e\n\u003ch3 data-end=\"2989\" data-start=\"2960\"\u003e5️⃣ Compact Yet Durable\u003c\/h3\u003e\n\u003cp data-end=\"3060\" data-start=\"2990\"\u003eWeighing only 624g with compact dimensions for easy field portability.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000107303124,"sku":"FK 1587","price":7402.1,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/FK1587.png?v=1769186294"},{"product_id":"fluke-1577-insulation-multimeter","title":"Fluke 1577 Insulation Multimeter | 1000V True-RMS","description":"\u003ch1 class=\"features-title\"\u003eFluke 1577 Insulation Multimeter\u003c\/h1\u003e\n\u003ch2 data-start=\"713\" data-end=\"764\"\u003e\u003cstrong data-start=\"716\" data-end=\"764\"\u003eOverview of Fluke 1577 Insulation Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"765\" data-end=\"1313\"\u003eThe \u003cstrong data-start=\"769\" data-end=\"805\"\u003eFluke 1577 Insulation Multimeter\u003c\/strong\u003e is a professional-grade testing instrument designed for insulation resistance testing and advanced electrical troubleshooting. Combining insulation testing up to 1000V with True-RMS multimeter functionality, the Fluke 1577 Insulation Multimeter allows technicians to measure voltage, resistance, continuity, and insulation safely and accurately. Its rugged design and clear digital display make it suitable for industrial, commercial, and maintenance environments where reliability and safety are essential.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1712\" data-end=\"1774\"\u003e\n\u003cp data-start=\"1714\" data-end=\"1774\"\u003eCombines \u003cstrong data-start=\"1723\" data-end=\"1772\"\u003e1000V insulation tester + true RMS multimeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1775\" data-end=\"1847\"\u003e\n\u003cp data-start=\"1777\" data-end=\"1847\"\u003e\u003cstrong data-start=\"1777\" data-end=\"1808\"\u003eTest voltages: 500V \/ 1000V\u003c\/strong\u003e with insulation range up to \u003cstrong data-start=\"1837\" data-end=\"1845\"\u003e2 GΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1848\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1850\" data-end=\"1915\"\u003eMeasures \u003cstrong data-start=\"1859\" data-end=\"1913\"\u003eAC\/DC voltage, resistance, continuity, and current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"1981\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1981\"\u003eTrue RMS accuracy for non-linear loads and noisy environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"2049\"\u003e\n\u003cp data-start=\"1984\" data-end=\"2049\"\u003eIncludes \u003cstrong data-start=\"1993\" data-end=\"2014\"\u003eremote test probe\u003c\/strong\u003e for easy one-handed measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2050\" data-end=\"2103\"\u003e\n\u003cp data-start=\"2052\" data-end=\"2103\"\u003e\u003cstrong data-start=\"2052\" data-end=\"2077\"\u003eLarge backlit display\u003c\/strong\u003e for improved visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2104\" data-end=\"2157\"\u003e\n\u003cp data-start=\"2106\" data-end=\"2157\"\u003eAuto power off, data hold, low battery indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2158\" data-end=\"2225\"\u003e\n\u003cp data-start=\"2160\" data-end=\"2225\"\u003eRugged Fluke build quality, \u003cstrong data-start=\"2188\" data-end=\"2225\"\u003eCAT III 1000V \/ CAT IV 600V rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2158\" data-end=\"2225\"\u003e\u003cstrong data-start=\"2188\" data-end=\"2225\"\u003eBuilt with FLUKE CONNECT\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(2.0%+2)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum test current @ 1kΩ\/V\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMaximum resistance per test voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e600 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMaximum resolution per test voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eAccuracy per test voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% - 95% (10°C – 30°C)\u003cbr\u003e0% - 75% (30°C – 40°C)\u003cbr\u003e0% - 40% (40°C – 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-033: CAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e203 x 100 x 50 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e624 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life alkaline\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeter use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation test use\u003c\/td\u003e\n\u003ctd\u003eMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat's in the box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eFour AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eCD rom with manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":46620330918100,"sku":"FK 1577","price":6206.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Fluke_1577_01.png?v=1773245553"}],"url":"https:\/\/techno.my\/collections\/fluke-insulation-testers.oembed","provider":"Techno Tools \u0026 Equipment","version":"1.0","type":"link"}