{"title":"Kyoritsu Clamp Meters","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eKyoritsu clamp meters cover the full spectrum of current measurement needs, from standard AC and AC\/DC clamp meters for general electrical work, leakage clamp meters for detecting earth fault currents, fork current testers for tight panel spaces, DC milliamp clamp meters and loggers for 4-20mA loop monitoring, clamp power meters for energy and power quality analysis, to digital multimeters with AC\/DC clamp sensors for combined measurement tasks. We carry \u003cstrong\u003e100% authentic\u003c\/strong\u003e Kyoritsu clamp meters, backed by \u003cstrong\u003emanufacturer warranty\u003c\/strong\u003e. As an authorized distributor, Techno Tools \u0026amp; Equipment offers \u003cstrong\u003ecompetitive pricing and fast delivery\u003c\/strong\u003e across Malaysia, with \u003cstrong\u003esame-day delivery for Klang Valley customers\u003c\/strong\u003e.\u003cbr\u003e\u003c\/p\u003e","products":[{"product_id":"kyoritsu-2000a-digital-multimeter-600v","title":"KYORITSU 2000A Digital Multimeter with AC\/DC Clamp Sensor ≤600V | KEW 2000A","description":"\u003ch1 class=\"goods_name\"\u003eKEW MATE 2000A Digital Multimeter with AC\/DC Clamp Sensor\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"771\" data-end=\"823\"\u003e\u003cstrong data-start=\"774\" data-end=\"823\"\u003eOverview of KYORITSU 2000A Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"824\" data-end=\"1361\"\u003eThe \u003cstrong data-start=\"828\" data-end=\"865\"\u003eKYORITSU 2000A Digital Multimeter\u003c\/strong\u003e is a high-precision instrument designed for measuring AC\/DC voltage, current, and resistance safely and accurately. Equipped with an AC\/DC clamp sensor, the KEW 2000A ensures stable readings and versatile measurement capabilities for residential, commercial, and industrial applications. Its ergonomic design and robust build make the KYORITSU 2000A Digital Multimeter an essential tool for electricians, technicians, and maintenance personnel performing daily field diagnostics and inspections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eVideo:\u003cbr\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/MUSXQhAcfEI\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e \u003cbr\u003e\n\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures both AC and DC currents up to 60A with the open clamp sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Cable Protection:\u003c\/strong\u003e Increased cable strength and robust protection ensure durability and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Portable:\u003c\/strong\u003e Pocket-size design makes it easy to carry and store without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Probe Holster:\u003c\/strong\u003e Test probe can be securely fixed to the holster for convenience and safe storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e Equipped with a test lead cap to protect against short circuit accidents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Clamp Jaws:\u003c\/strong\u003e The open jaws are slim, making them perfect for clamping wires even in tight spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e340.0mV \/ 3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (50 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e60.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e340.0Ω \/ 3.400kΩ \/ 34.00kΩ \/ 340.0kΩ \/ 3.400MΩ \/ 34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (0 - 340kΩ); ±5%rdg ±5dgt (3.4MΩ); ±15%rdg ±5dgt (34MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 30 ±10Ω\u003c\/td\u003e\n\u003ctd\u003eWorks only on 340Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eAC A: 3.4Hz - 10kHz; AC V: 3.4Hz - 300kHz\u003c\/td\u003e\n\u003ctd\u003e±0.1%rdg ±1dgt (Current \u0026gt; 15A, Voltage \u0026gt; 30V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ6mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V \/ CAT II 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm × 87 mm × 24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 210g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (R03), instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eSoft carrying case (9107)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42978555101396,"sku":"KE 2000A","price":833.2,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/75702c7bc01a377d0812877ccf1e66d8_7a75ec41-eeb5-41c1-bc26-5032160cb7e1.jpg?v=1769185086"},{"product_id":"kyoritsu-2431-leakage-clamp-meter","title":"KYORITSU 2431 Leakage Clamp Meter","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2431 Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"727\" data-end=\"779\"\u003e\u003cstrong data-start=\"730\" data-end=\"779\"\u003eOverview of KYORITSU 2431 Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"780\" data-end=\"1287\"\u003eThe \u003cstrong data-start=\"784\" data-end=\"821\"\u003eKYORITSU 2431 Leakage Clamp Meter\u003c\/strong\u003e is a high-performance instrument designed for accurate leakage current measurement in residential, commercial, and industrial electrical systems. The KEW 2431 ensures safe, reliable, and stable readings with its clear digital display and user-friendly design. Its compact size and professional-grade performance make the KYORITSU 2431 Leakage Clamp Meter an essential tool for electricians, maintenance engineers, and technicians performing daily field diagnostics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Eliminates harmonic effects for precise measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power-Off Function:\u003c\/strong\u003e Enhances battery efficiency by turning off the device when idle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotary Switch:\u003c\/strong\u003e Enables effortless power-on and range selection with one hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and easy to carry, suitable for on-site inspections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.01mA for detecting small leakage currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 200mA \/ 200A\u003c\/td\u003e\n\u003ctd\u003e±3%rdg ±5dgt (20\/200mA\/100A); ±5%rdg ±5dgt (200A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 200mA \/ 200A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±4dgt [50\/60Hz] (20\/200mA\/0 - 100A); ±5%rdg ±6dgt [40 - 400Hz] (20\/200mA\/0 - 100A); ±5%rdg ±4dgt [50\/60Hz] (100.1 - 200A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø24mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003eφ15mm 100A\u003c\/td\u003e\n\u003ctd\u003e10mA AC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × LR44 (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e149 mm × 60 mm × 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9090), 2 × LR44 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982649823444,"sku":"KE 2431","price":2379.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/e72912100abb3e0c25c100d0429825c4_f1b0faaa-f582-4f35-b5eb-584e77c91fb4.jpg?v=1769185138"},{"product_id":"kyoritsu-kt200-ac-digital-clamp-meter","title":"KYORITSU KT200 AC Digital Clamp Meter | KEWTECH KT 200 Meter","description":"\u003ch1 class=\"goods_name\"\u003eKT 200 AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"786\" data-end=\"842\"\u003e\u003cstrong data-start=\"789\" data-end=\"842\"\u003eOverview of KYORITSU KT200 AC Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"843\" data-end=\"1400\"\u003eThe \u003cstrong data-start=\"847\" data-end=\"888\"\u003eKYORITSU KT200 AC Digital Clamp Meter\u003c\/strong\u003e is a compact and reliable current measurement tool designed for electrical professionals who require accurate readings and dependable performance. Engineered for residential, commercial, and industrial environments, the KEWTECH KT 200 provides clear digital indication and stable AC current measurement. With its lightweight form factor and robust construction, the KYORITSU KT200 AC Digital Clamp Meter ensures ease of use and long-term reliability for electricians, service technicians, and maintenance teams.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Handy Design:\u003c\/strong\u003e Lightweight and portable for easy operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A AC Clamp Meter:\u003c\/strong\u003e Handles medium-range AC current measurements with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive DMM Function:\u003c\/strong\u003e Measures AC voltage, DC voltage, resistance, and includes a continuity buzzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V \/ CAT II 600V for secure operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable and Efficient:\u003c\/strong\u003e Provides up to 200 hours of continuous measuring time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±6dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e400Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ30mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V (ACA) \/ CAT II 600V, Pollution Degree 2; IEC 61010-2-032; IEC 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 200 hours (auto power save after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e184 mm × 44 mm × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 190g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9105)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982685081812,"sku":"KE KT200","price":461.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/7ad7f48343efc80dce30f0b95155fb69_5d719ca2-e93b-4157-beb0-2425dffebb36.jpg?v=1769185143"},{"product_id":"kyoritsu-2007r-ac-digital-clamp-meter","title":"KYORITSU 2007R AC Digital Clamp Meter | KEW 2007R Clamp Meter","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2007R AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"653\" data-end=\"709\"\u003e\u003cstrong data-start=\"656\" data-end=\"709\"\u003eOverview of KYORITSU 2007R AC Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"710\" data-end=\"1248\"\u003eThe \u003cstrong data-start=\"714\" data-end=\"755\"\u003eKYORITSU 2007R AC Digital Clamp Meter\u003c\/strong\u003e is a compact, durable, and professional measurement tool designed for precise AC current testing in residential, commercial, and industrial environments. With its ergonomic design and high-accuracy sensing technology, the KEW 2007R ensures stable and reliable readings during daily electrical diagnostic tasks. The KYORITSU 2007R AC Digital Clamp Meter is ideal for electricians, service technicians, and maintenance engineers who require consistent and safe current measurement capabilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Safety Jaw:\u003c\/strong\u003e Ensures reliable and safe measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e The over-molded body allows for convenient one-hand operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e True RMS auto-ranging for AC currents up to 1000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear Display:\u003c\/strong\u003e Large, easy-to-read display with 0.1A resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Battery Life:\u003c\/strong\u003e Features long-lasting power for extended use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Complies with IEC 61010-1 CAT IV 300V \/ CAT III 600V for safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e600.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt (45 - 65Hz); ±2.0%rdg ±4dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (AC V)\u003c\/td\u003e\n\u003ctd\u003e600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.2%rdg ±3dgt (45 - 65Hz); ±1.5%rdg ±4dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DC V)\u003c\/td\u003e\n\u003ctd\u003e600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.2%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±5dgt (600Ω); ±2.0%rdg ±3dgt (6.000kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eSounds below 90Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2 (EMC), IEC 60529 IP40, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 170 hours (when R03 is used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e204 mm × 81 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), carrying case (9079), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982704709844,"sku":"KE 2007R","price":845.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/KE2007R.png?v=1769185154"},{"product_id":"kyoritsu-kt203-ac-dc-digital-clamp-mete","title":"KYORITSU KT203 AC\/DC Digital Clamp Meter | KEWTECH KT 203","description":"\u003ch1 class=\"goods_name\"\u003eKT 203 AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"287\" data-end=\"362\"\u003eKYORITSU KT203 AC\/DC Digital Clamp Meter | KEWTECH KT 203\u003c\/h2\u003e\n\u003cp data-start=\"363\" data-end=\"687\"\u003eThe \u003cstrong data-start=\"367\" data-end=\"411\"\u003eKYORITSU KT203 AC\/DC Digital Clamp Meter\u003c\/strong\u003e delivers reliable measurement performance for electricians and maintenance professionals who require accurate current testing without contact interruption. The KEWTECH KT 203 is designed for safe, efficient diagnostics in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Lightweight:\u003c\/strong\u003e Designed for easy handling and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures currents up to 400A with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDMM Functions:\u003c\/strong\u003e Supports AC\/DC voltage, resistance, and continuity testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V \/ CAT II 600V for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable and Reliable:\u003c\/strong\u003e Built to handle tough environments with robust performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±8dgt [50\/60Hz] (0 - 40.00A); ±3.5%rdg ±6dgt [50\/60Hz] (15.0 - 299.9A); ±4.0%rdg ±6dgt [50\/60Hz] (300.0 - 400.0A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±8dgt (0 - 40.00A); ±3.5%rdg ±6dgt (15.0 - 299.9A); ±4.0%rdg ±6dgt (300.0 - 400.0A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt [50\/60Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ30mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V (ACA) \/ CAT II 600V Pollution Degree 2; IEC 61010-2-032; IEC 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e187 mm × 68.5 mm × 38.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 200g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9105)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3 data-start=\"1252\" data-end=\"1283\"\u003eWhy Choose KYORITSU KT203\u003c\/h3\u003e\n\u003cp data-start=\"1284\" data-end=\"1505\"\u003eThe KYORITSU KT203 provides a dependable combination of precision, durability, and portability. Its True RMS capability ensures accurate readings even in non-linear loads, making it suitable for modern electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982707593428,"sku":"KE KT203","price":845.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/1af247a8d4b23bde71e1c344258a263e_74d54c14-cc2f-4dba-9d44-14bb581fc9a4.jpg?v=1769185168"},{"product_id":"kyoritsu-2433r-leakage-clamp-meter","title":"KYORITSU 2433R Leakage Clamp Meter – KEW 2433R","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2433R Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"844\" data-end=\"895\"\u003e\u003cstrong data-start=\"849\" data-end=\"895\"\u003eKYORITSU 2433R Leakage Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"897\" data-end=\"1502\"\u003eThe \u003cstrong data-start=\"901\" data-end=\"947\"\u003eKYORITSU 2433R Leakage Digital Clamp Meter\u003c\/strong\u003e is a professional instrument designed for accurate measurement of leakage currents in electrical circuits. The \u003cstrong data-start=\"1059\" data-end=\"1072\"\u003eKEW 2433R\u003c\/strong\u003e ensures reliable readings for electricians, technicians, and maintenance personnel in industrial, commercial, and residential settings. Its ergonomic and compact design allows safe and easy handling in the field. With a clear digital display and simple operation, the KYORITSU 2433R Leakage Clamp Meter delivers fast and dependable measurements for troubleshooting, preventive maintenance, and verification of electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Eliminates harmonic effects for accurate and reliable measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Measurement Ranges:\u003c\/strong\u003e 40mA, 400mA, and 400A for diverse applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.01mA enables detection of very small leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates effectively between 20Hz and 1kHz (40Hz to 1kHz for 400A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and ergonomic, ideal for fieldwork and on-site inspections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V standards for safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (40\/400mA); ±1%rdg ±5dgt (0 - 300A); ±2%rdg (300.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±10dgt [20Hz - 1kHz] (40\/400mA); ±2.5%rdg ±10dgt [40Hz - 1kHz] (0 - 300A); ±5%rdg [40Hz - 1kHz] (300.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC (Line\/Neutral); 300V AC\/DC (Earth)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø40mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eApprox. 10mA AC near a 15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz - 1kHz (40Hz - 1kHz for 400A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm × 81 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9052), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42983343554772,"sku":"KE 2433R","price":3186.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/00836a2e8c9bc665ff7b2a3c9e62c184_429782d5-f6d1-4b25-93a8-f63920982d0f.jpg?v=1769185175"},{"product_id":"kyoritsu-2012ra-digital-multimeter","title":"KYORITSU 2012RA Digital Multimeter with AC\/DC Clamp Sensor ≤600V | KEW 2012RA","description":"\u003ch1 class=\"goods_name\"\u003eKEW MATE 2012RA Digital Multimeter with AC\/DC Clamp Sensor\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eKYORITSU 2012RA Digital Multimeter ≤600V with AC\/DC Clamp Sensor\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2012RA Digital Multimeter\u003c\/strong\u003e is a high-precision instrument designed for accurate AC\/DC voltage measurements up to 600V. The \u003cstrong\u003eKEW 2012RA\u003c\/strong\u003e includes a built-in AC\/DC clamp sensor, allowing current measurements without disconnecting circuits. Its compact, durable design ensures reliability for electricians, technicians, and maintenance professionals performing field inspections, industrial troubleshooting, or workshop diagnostics. The clear LCD display provides fast, accurate readings, and the rugged housing ensures protection during daily use.\u003c\/p\u003e\n\u003ch1\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2012RA Digital Multimeter\u003c\/strong\u003e combines versatility and portability in a single device. It enables users to measure AC\/DC voltage, resistance, continuity, and current using the integrated clamp sensor. Suitable for industrial, commercial, and residential applications, the KEW 2012RA ensures safe, efficient, and accurate electrical testing. Lightweight yet durable, this multimeter is designed for professionals who require a reliable, multi-functional measurement tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eVideo:\u003cbr\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/a8DQVwbSriA\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e \u003ciframe src=\"https:\/\/www.youtube.com\/embed\/mZdYkkV38OM\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e \u003ciframe src=\"https:\/\/www.youtube.com\/embed\/MUSXQhAcfEI\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/kewmate_img02_en.jpg?v=1733479327\" alt=\"\"\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Measures up to 120A for both AC and DC currents with the OPEN CLAMP SENSOR.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Cable Protection:\u003c\/strong\u003e Improved cable strength and protection ensure durability during use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Portable:\u003c\/strong\u003e Small, pocket-sized design for easy portability and convenient storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Probe Holster:\u003c\/strong\u003e Test probe can be securely fixed to the holster for safe and convenient handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e Includes a test lead cap to prevent short circuit accidents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlim Clamp Jaws:\u003c\/strong\u003e The open jaws are designed to fit into tight spaces, making it easy to clamp wires in cramped environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600.0mV \/ 6.000V \/ 60.00V \/ 600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6.000V \/ 60.00V \/ 600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (45 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 120.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±8dgt (60A); ±2.0%rdg ±5dgt (120A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 120.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (45 - 65Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ \/ 60.00kΩ \/ 600.0kΩ \/ 6.000MΩ \/ 60.00MΩ\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±5dgt (600Ω - 600kΩ); ±2.0%rdg ±5dgt (6MΩ); ±3.0%rdg ±5dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 35 ±25Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e2.000V\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±5dgt (Open-loop voltage: approx. 2.7V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance (F)\u003c\/td\u003e\n\u003ctd\u003e400.0nF \/ 4.000µF \/ 40.00µF\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±10dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eAC A: 99.99Hz \/ 400Hz; AC V: 99.99Hz \/ 999.9Hz \/ 9.999kHz \/ 99.99kHz \/ 300.0kHz\u003c\/td\u003e\n\u003ctd\u003e±0.2%rdg ±2dgt (100Hz); ±0.1%rdg ±1dgt (1000Hz \/ 10kHz \/ 300kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ12mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V, CAT II 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm × 92 mm × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads, 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eSoft carrying case (9107)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42983368261844,"sku":"KE 2012RA","price":1068.2,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/b55d53c22b7251df265944f011dee748_b2c28d3c-1293-42ea-b327-94a5ad0c6c65.jpg?v=1769185225"},{"product_id":"kyoritsu-2200r-digital-clamp-meter-with-true-rms-ke2200r-1000a-ac-and-600v-ranging","title":"KYORITSU 2200R Digital Clamp Meter | KEW 2200R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2200R AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"809\" data-end=\"852\"\u003e\u003cstrong data-start=\"814\" data-end=\"852\"\u003eKYORITSU 2200R Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"854\" data-end=\"1472\"\u003eThe \u003cstrong data-start=\"858\" data-end=\"896\"\u003eKYORITSU 2200R Digital Clamp Meter\u003c\/strong\u003e is a high-accuracy instrument for measuring AC\/DC current, voltage, and resistance. The \u003cstrong data-start=\"985\" data-end=\"998\"\u003eKEW 2200R\u003c\/strong\u003e allows safe and efficient clamp measurements without disconnecting circuits, making it ideal for electricians, technicians, and maintenance professionals. Its compact, ergonomic design ensures portability, while the durable housing protects the meter during regular field use. With a clear digital display, the KYORITSU 2200R Digital Clamp Meter delivers fast, reliable readings, ensuring accurate electrical testing in workshops, industrial sites, and on-site inspections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/2200.png?v=1733495870\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Slim and Lightweight:\u003c\/strong\u003e Compact design for easy portability and handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTeardrop-Shaped Jaws:\u003c\/strong\u003e φ33mm jaws for convenient operation in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000A AC Clamp Meter:\u003c\/strong\u003e Measures high AC currents with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive DMM Function:\u003c\/strong\u003e Measures AC voltage, DC voltage, resistance, and includes a continuity buzzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuseless Protection:\u003c\/strong\u003e Protects Ω\/Continuity measurements up to 600V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Resolution:\u003c\/strong\u003e Offers a resolution of 0.01A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 300V \/ CAT III 600V and IEC 61010-2-032 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (45 - 65Hz); ±2.0%rdg ±5dgt (40 - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.8%rdg ±7dgt (45 - 65Hz); ±2.3%rdg ±8dgt (65 - 500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0mV \/ 4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt (400mV range excluded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4.000kΩ \/ 40.00kΩ \/ 400.0kΩ \/ 4.000MΩ \/ 40.00MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±4dgt (0 - 400kΩ); ±4.0%rdg ±4dgt (4MΩ); ±8.0%rdg ±4dgt (40MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±30Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V (AC A); CAT III 300V \/ CAT II 600V (AC\/DC V), Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 120 hours (auto power off after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 mm × 68 mm × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7107A), carrying case (9160), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43000954454228,"sku":"KE 2200R","price":542.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kew_2200r_01.png?v=1769186599"},{"product_id":"kyoritsu-2200-digital-clamp-meter","title":"KYORITSU 2200 Digital Clamp Meter | KEW 2200","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2200 AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"733\" data-end=\"775\"\u003e\u003cstrong data-start=\"738\" data-end=\"775\"\u003eKYORITSU 2200 Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"777\" data-end=\"1387\"\u003eThe \u003cstrong data-start=\"781\" data-end=\"818\"\u003eKYORITSU 2200 Digital Clamp Meter\u003c\/strong\u003e is a reliable and precise instrument for measuring AC\/DC current, voltage, and resistance. The \u003cstrong data-start=\"914\" data-end=\"926\"\u003eKEW 2200\u003c\/strong\u003e provides safe clamp measurements without disconnecting circuits, making it suitable for electricians, technicians, and maintenance professionals. Its compact, ergonomic design ensures portability, while durable housing protects the device during field and workshop use. The clear digital display of the KYORITSU 2200 Digital Clamp Meter delivers fast, consistent readings for accurate electrical testing in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/2200.png?v=1733495870\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Slim and Lightweight:\u003c\/strong\u003e Handy design for easy use and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTeardrop-Shaped Jaws:\u003c\/strong\u003e φ33mm jaws allow easy access to wires in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000A AC Clamp Meter:\u003c\/strong\u003e Handles high current measurements with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive DMM Function:\u003c\/strong\u003e Measures AC voltage, DC voltage, resistance, and includes a continuity buzzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuseless Protection:\u003c\/strong\u003e Electronic protection on Ω\/Continuity up to 600V ensures safety and durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Resolution:\u003c\/strong\u003e Achieves a resolution of 0.01A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 600V and IEC 61010-2-032 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.4%rdg ±6dgt (50\/60Hz); ±1.6%rdg ±6dgt (45 - 65Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.8%rdg ±7dgt (45 - 65Hz); ±2.3%rdg ±8dgt (65 - 500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0mV \/ 4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4.000kΩ \/ 40.00kΩ \/ 400.0kΩ \/ 4.000MΩ \/ 40.00MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±4dgt (0 - 400kΩ); ±4.0%rdg ±4dgt (4MΩ); ±8.0%rdg ±4dgt (40MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±30Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 600V (AC A); CAT III 300V \/ CAT II 600V (AC\/DC V), Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 350 hours (auto power off after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 mm × 68 mm × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7107A), carrying case (9160), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43000962154708,"sku":"KE 2200","price":443.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kew_2200__01.png?v=1769186604"},{"product_id":"kyoritsu-2433-leakage-clamp-meter","title":"KYORITSU 2433 Leakage Clamp Meter","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2433 Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"755\" data-end=\"806\"\u003e\u003cstrong data-start=\"758\" data-end=\"806\"\u003eKYORITSU 2433 Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"808\" data-end=\"1437\"\u003eThe \u003cstrong data-start=\"812\" data-end=\"849\"\u003eKYORITSU 2433 Leakage Clamp Meter\u003c\/strong\u003e is engineered for precise detection and measurement of leakage currents in residential, commercial, and industrial electrical systems. Designed for technicians who need accuracy and stability, the KYORITSU 2433 Leakage Clamp Meter ensures safe troubleshooting, preventive maintenance, and insulation monitoring. Its compact jaw structure allows easy clamping on tightly packed cables, providing reliable performance even in complex environments. This instrument is an essential tool for electrical engineers and maintenance teams responsible for safety compliance and system diagnostics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Reduces the effects of harmonics for accurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Measurement Ranges:\u003c\/strong\u003e 40mA, 400mA, and 400A for versatile applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.01mA for detecting small leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates effectively between 20Hz and 1kHz (40Hz to 1kHz for 400A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Lightweight:\u003c\/strong\u003e Ideal for on-site inspections with convenient handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (40\/400mA); ±1%rdg ±5dgt (0 - 350A); ±2%rdg (350.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±10dgt [20Hz - 1kHz] (40\/400mA); ±2.5%rdg ±10dgt [40Hz - 1kHz] (0 - 350A); ±5%rdg [40Hz - 1kHz] (350.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC (Line\/Neutral); 300V AC\/DC (Earth)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø40mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eApprox. 10mA AC near a 15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz - 1kHz (40Hz - 1kHz for 400A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm × 81 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9097), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43072775258324,"sku":"KE 2433","price":2676.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/2916302be6eb045f215507dc6b9274e6.jpg?v=1770653697"},{"product_id":"kyoritsu-2003a-ac-dc-clamp-meters","title":"KYORITSU 2003A AC\/DC Clamp Meter – KEW 2003A","description":"\u003ch1\u003eKYORITSU 2003A AC\/DC \u003cmeta charset=\"utf-8\"\u003eDigital Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2003A AC\/DC Digital Clamp Meters\u003c\/strong\u003e are high-precision instruments designed for safe and accurate measurement of AC and DC currents in residential, commercial, and industrial electrical systems. The KEW 2003A features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable and efficient operation. Its portability and performance make the KYORITSU 2003A AC\/DC Digital Clamp Meters ideal for electricians, maintenance technicians, and engineers who require precise current measurement for daily field operations.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe KYORITSU 2003A AC\/DC Digital Clamp Meters deliver accurate AC\/DC current measurements in a portable and easy-to-use design. The KEW 2003A combines reliable readings with a lightweight ergonomic form, making it ideal for maintenance, troubleshooting, and inspection tasks in electrical systems. Its durable build ensures long-term reliability, even in demanding environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Transformer Jaws:\u003c\/strong\u003e Measures currents on conductors up to Ø55mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Range:\u003c\/strong\u003e Measures both AC and DC currents up to 2000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminal:\u003c\/strong\u003e Enables connection to recorders for detailed data analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurements:\u003c\/strong\u003e Supports AC\/DC voltage, resistance, and continuity testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Readings:\u003c\/strong\u003e Offers a minimum resolution of 0.1A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 600V \/ CAT III 1000V for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e400A \/ 2000A (0 - 1000A)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt [50\/60Hz]; ±3%rdg ±4dgt [40 - 500Hz]; ±5%rdg ±4dgt [500Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e2000A (1001 - 1999A)\u003c\/td\u003e\n\u003ctd\u003e±3%rdg ±2dgt [50\/60Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e400A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e400V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt [50\/60Hz]; ±1.5%rdg ±4dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400Ω \/ 4000Ω\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e400Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC400mV (against AC\/DC400A); DC200mV (against AC\/DC2000A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V \/ CAT III 1000V; IEC 61010-031; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 530g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7107A), carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43072894501076,"sku":"KE 2003A","price":1676.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/34c79b0b0ce830d927e6f630cbc1381a.jpg?v=1770653790"},{"product_id":"kyoritsu-2413r-leakage-clamp-meter","title":"KYORITSU 2413R Leakage Clamp Meter – KEW 2413R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2413R Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"865\" data-end=\"908\"\u003e\u003cstrong data-start=\"868\" data-end=\"906\"\u003eKYORITSU 2413R Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"909\" data-end=\"1361\"\u003eThe \u003cstrong data-start=\"913\" data-end=\"951\"\u003eKYORITSU 2413R Leakage Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC\/DC leakage current measurement. The KEW 2413R features a compact ergonomic design, clear digital display, and stable readings for reliable operation. Its portability and performance make the KYORITSU 2413R Leakage Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field testing, troubleshooting, and inspection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Transformer Jaws:\u003c\/strong\u003e Easily clamps on 3-phase systems for leakage current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Filter Switch:\u003c\/strong\u003e Reduces harmonic interference for precise readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Way Analog Output:\u003c\/strong\u003e Supports waveform and recorder outputs for advanced data logging and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Handles currents up to 1000A with excellent accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±5dgt (200mA \/ 2A \/ 20A); ±3.0%rdg ±5dgt (200A, 0 - 500A); ±5.5%rdg (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.8%rdg ±5dgt (200mA \/ 2A \/ 20A); ±2.0%rdg ±5dgt (200A, 0 - 500A); ±5.0%rdg (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e3.0 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø68mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOutput Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform Output\u003c\/td\u003e\n\u003ctd\u003eAC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003eDC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e1 × 6F22 (9V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 60 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 130 mm × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 600g (including battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9094), 1 × 6F22 (9V) battery, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e2WAY Output Cord (7073)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43072945619156,"sku":"KE 2413R","price":2962.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/737cf94be80f97174f607c2294cda44b.jpg?v=1770653804"},{"product_id":"kyoritsu-2031-ac-digital-clamp-meters","title":"KYORITSU 2031 AC Digital Clamp Meter – KEW 2031","description":"\u003cdiv\u003e\n\u003ch1\u003e\u003cstrong\u003eKYORITSU 2031 AC Digital Clamp Meter\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2031 AC Digital Clamp Meters\u003c\/strong\u003e are precision instruments designed for safe and accurate AC current measurement. The KEW 2031 features a compact ergonomic design, clear digital display, and stable readings for reliable operation. Its portability and performance make the KYORITSU 2031 AC Digital Clamp Meters ideal for electricians, maintenance technicians, and engineers performing field testing and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Measures AC currents up to 200A with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and easy to handle, perfect for fieldwork.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Measurement:\u003c\/strong\u003e Minimum resolution of 0.01A for accurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThin Clamp Jaws:\u003c\/strong\u003e φ24mm tear drop-shaped jaws allow clamping in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Measures currents with a frequency response of 40Hz - 1kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50\/60Hz); ±3%rdg ±10dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ24mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × LR44 (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e147 mm × 58.5 mm × 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9090), 2 × LR44 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073004962004,"sku":"KE 2031","price":686.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/b0d41ee2d35de34a9e13fe544329f683.jpg?v=1770653824"},{"product_id":"kyoritsu-2010-ac-dc-clamp-meters","title":"KYORITSU 2010 AC\/DC Clamp Meter | KEW 2010","description":"\u003cdiv\u003e\n\u003ch1\u003eKYORITSU 2010 AC\/DC Digital Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2010 AC\/DC Digital Clamp Meters\u003c\/strong\u003e are high-precision instruments designed for safe and accurate measurement of AC and DC currents. The KEW 2010 features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2010 AC\/DC Digital Clamp Meters ideal for electricians, maintenance technicians, and engineers performing field testing and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Measures small currents with resolutions of 0.1mA (AC) and 1mA (DC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMiniature Design:\u003c\/strong\u003e Compact and lightweight for easy handling and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminal:\u003c\/strong\u003e Connects to recorders for detailed current analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates from DC to 2kHz for versatile measurement needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe for Low-Voltage Circuits:\u003c\/strong\u003e Designed for use on circuits below 60V AC\/DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt [50\/60Hz] (200mA); ±1.5%rdg ±8dgt [40Hz - 2kHz] (200mA); ±1%rdg ±2dgt [50\/60Hz] (2A); ±2.5%rdg ±10dgt [40Hz - 2kHz] (2\/20A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e2A \/ 20A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt (2A); ±1.5%rdg ±4dgt (20A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC, 40Hz - 2kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC200mV (against AC200mA\/2\/20A and DC2\/20A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ7.5mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e6LR61 (9V) × 1 or AC Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142 mm × 64 mm × 26 mm (Main Unit); 153 mm × 23 mm × 18 mm (Clamp Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9095), 6LF22 × 1, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073077215444,"sku":"KE 2010","price":2974.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/7ee9f430a257e18ca926bfc5510da65d.jpg?v=1770653823"},{"product_id":"kyoritsu-2210r-ac-clamp-meter","title":"KYORITSU 2210R AC Clamp Meter – KEW 2210R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2210R AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"821\" data-end=\"859\"\u003e\u003cstrong data-start=\"824\" data-end=\"857\"\u003eKYORITSU 2210R AC Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"860\" data-end=\"1278\"\u003eThe \u003cstrong data-start=\"864\" data-end=\"897\"\u003eKYORITSU 2210R AC Clamp Meter\u003c\/strong\u003e is a precision instrument designed for accurate AC current measurement. The KEW 2210R features a compact and ergonomic design with a clear digital display, ensuring reliable and stable readings. Its portability makes the KYORITSU 2210R AC Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field measurements, troubleshooting, and inspections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eVideo:\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/ZCcCEt5hfwY\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible and Lightweight Clamp Sensor:\u003c\/strong\u003e Provides convenience for measurements in tight or hard-to-reach spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Reading Range:\u003c\/strong\u003e Measures AC currents up to 3000A for industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS:\u003c\/strong\u003e Ensures precise measurements, even for distorted waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMIN\/MAX Function:\u003c\/strong\u003e Records the minimum and maximum current values during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit LCD Display:\u003c\/strong\u003e Offers excellent visibility in low-light conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 600V \/ CAT III 1000V requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e Provides a resolution of 0.01A for detailed and accurate readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e30.00A \/ 300.0A \/ 3000A\u003c\/td\u003e\n\u003ctd\u003e±3%rdg ±5dgt [45 - 500Hz] (At the center of the circle formed by the flexible sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003eFull scale CF \u0026lt;1.6; half scale CF \u0026lt;3.2\u003c\/td\u003e\n\u003ctd\u003eEffective input crest values are √2 times the max values of each range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ150mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfluence of Conductor Position\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAdditional ±3% (max.) depending on the distance from the center position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e5000A AC for 10 seconds\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, IEC 61010-2-032 CAT IV 600V \/ CAT III 1000V, Pollution Degree 2, IEC 61326-1 (EMC), IEC 60529 IP40, EN50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature and Humidity Range\u003c\/td\u003e\n\u003ctd\u003e0 - +50°C; relative humidity 80% or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature and Humidity Range\u003c\/td\u003e\n\u003ctd\u003e-10 - +60°C; relative humidity 70% or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 120 hours (auto power off after approx. 15 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm × 70 mm × 26 mm (Display unit); φ8.5mm (Cable diameter); 1.8m (Cable length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 300g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9174), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073083637972,"sku":"KE 2210R","price":1826.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/545f4f09cb649aaf5bb9726fd0f6eba8.jpg?v=1770653823"},{"product_id":"kyoritsu-2434-leakage-clamp-meter","title":"KYORITSU 2434 Leakage Clamp Meter – Digital KEW 2434","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2434 Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eKYORITSU 2434 Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2434 Leakage Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC\/DC leakage current measurement. The KEW 2434 offers a clear digital display, compact and ergonomic design, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2434 Leakage Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field testing and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Stray Magnetic Field Resistance:\u003c\/strong\u003e Delivers accurate results with minimal interference from external fields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Reduces harmonic effects for consistent and precise measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.1mA for detecting small leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and easy to handle, suitable for fieldwork.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V requirements for safe usage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e400mA \/ 4A \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e400mA \/ 4A \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±4dgt [50\/60Hz]; ±3%rdg ±5dgt [40 - 400Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø28mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20mA AC max. near a φ15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\n\u003cbr\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e169 mm × 75 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9097), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073100087508,"sku":"KE 2434","price":1843.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/8c540a35f55dfb362beeb36417fac93a.jpg?v=1770653830"},{"product_id":"kyoritsu-2009r-clamp-meter","title":"KYORITSU 2009R AC\/DC Clamp Meter – Digital KEW 2009R","description":"\u003ch1\u003eKYORITSU 2009R AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2009R Clamp Meter\u003c\/strong\u003e is a precision instrument designed for accurate AC\/DC current measurement. The KEW 2009R features a compact, ergonomic design with a clear digital display and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2009R Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field measurements and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Instrument:\u003c\/strong\u003e Ensures accurate measurements of distorted waveforms and non-sinusoidal signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Handles AC and DC currents up to 2000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminal:\u003c\/strong\u003e Enables recorder connection for efficient data analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurements:\u003c\/strong\u003e Supports AC\/DC voltage, resistance, continuity testing, and frequency measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e Offers a minimum resolution of 0.1A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 600V \/ CAT III 1000V standards for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e400.0A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±3dgt (0 - 400.0A, 150 - 1700A) [45 - 66Hz]; ±2.0%rdg ±5dgt (20Hz - 1kHz); ±2.3%rdg ±3dgt (1701 - 2000A) [45 - 66Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e400.0A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e40.00V \/ 400.0V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt [45 - 66Hz]; ±1.5%rdg ±5dgt [20Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e40.00V \/ 400.0V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt (Electronic protection up to 600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 20 ±1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e10.0 - 4000Hz\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (Input sensitivity: Current \u0026gt;40A, Voltage \u0026gt;10V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC400mV (against AC\/DC400.0A); DC200mV (against AC\/DC2000A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V \/ CAT III 1000V, Pollution Degree 2; IEC 61010-031; IEC 61010-2-032; IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 540g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7107A), carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073106510036,"sku":"KE 2009R","price":2131.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/25d375d954227bd8bfe2aa859b8fe55f.jpg?v=1770653829"},{"product_id":"kyoritsu-2608a-analog-clamp-meter","title":"KYORITSU 2608A Analog Clamp Meter – KEW 2608A","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2608A AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"842\" data-end=\"884\"\u003e\u003cstrong data-start=\"845\" data-end=\"882\"\u003eKYORITSU 2608A Analog Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"885\" data-end=\"1336\"\u003eThe \u003cstrong data-start=\"889\" data-end=\"926\"\u003eKYORITSU 2608A Analog Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC\/DC current measurements with an analog display. The KEW 2608A offers a compact, ergonomic design with clear scale readings, ensuring reliable operation. Its portability and analog simplicity make the KYORITSU 2608A Analog Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field measurements and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Range:\u003c\/strong\u003e Essential for testing emergency battery-operated power supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTear Drop-Shaped Jaws:\u003c\/strong\u003e Designed for ease of use and access in restricted spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Measures AC current, AC voltage, DC voltage, and resistance effectively.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Lightweight:\u003c\/strong\u003e Ergonomic design for portability and user convenience.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V standards for safe and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e6A \/ 15A \/ 60A \/ 150A \/ 300A\u003c\/td\u003e\n\u003ctd\u003e±3% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e150V \/ 300V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±3% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e60V\u003c\/td\u003e\n\u003ctd\u003e±3% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e1Ω \/ 10kΩ (25Ω \/ 250Ω mid-scale)\u003c\/td\u003e\n\u003ctd\u003e±2% of scale length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V, Pollution Degree 2; IEC 61010-2-031; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e1 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e193 mm × 78 mm × 39 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 275g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), fuse (8923, 0.5A\/600V) × 2, carrying case (9097), 1 × R6 (AA) battery, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073116602580,"sku":"KE 2608A","price":665.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/3daaebf294f0b058a69ddfd0686b63de.jpg?v=1770653829"},{"product_id":"kyoritsu-2002r-ac-clamp-meter","title":"KYORITSU 2002R AC Clamp Meter – Digital KEW 2002R","description":"\u003cdiv\u003e\n\u003ch1\u003eKYORITSU 2002R AC Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2002R AC Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC current measurements. The KEW 2002R features a compact, ergonomic design with a clear digital display and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2002R AC Clamp Meter ideal for electricians, maintenance technicians, and engineers performing daily field measurements.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe KYORITSU 2002R AC Clamp Meter delivers fast and accurate AC current readings in a lightweight, easy-to-use design. The KEW 2002R combines reliable measurement with ergonomic portability, making it perfect for troubleshooting, maintenance, and inspection tasks. Its robust construction ensures long-term durability in demanding electrical environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Measures AC currents up to 2000A with excellent accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Hold Function:\u003c\/strong\u003e Captures and holds peak values for transient signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Tear Drop Shaped Jaws:\u003c\/strong\u003e φ55mm jaws for easy clamping of conductors, even in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Minimum resolution of 0.1A ensures precise readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Measurement Options:\u003c\/strong\u003e Measures AC current, AC\/DC voltage, resistance, and more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e400A (0 - 400A)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±3dgt (45 - 65Hz); ±2.5%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (0 - 1500A)\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (45 - 65Hz); ±3%rdg ±5dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (1500 - 2000A)\u003c\/td\u003e\n\u003ctd\u003e±4%rdg (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (AC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt (45 - 65Hz); ±1.5%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400Ω \/ 4kΩ \/ 40kΩ \/ 400kΩ\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eDC400mV against AC400A; DC200mV against AC2000A\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ55mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e247 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7107A), carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073137279188,"sku":"KE 2002R","price":1796.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/13c3f73ad92620519250f9953d38baf5.jpg?v=1770653858"},{"product_id":"kyoritsu-2001a-digital-multimeter","title":"KYORITSU 2001A Digital Multimeter with AC\/DC Clamp Sensor ≤600V","description":"\u003ch1 class=\"goods_name\"\u003eKEW MATE 2001A Digital Multimeter with AC\/DC Clamp Sensor\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"898\" data-end=\"940\"\u003e\u003cstrong data-start=\"901\" data-end=\"938\"\u003eKYORITSU 2001A Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"941\" data-end=\"1446\"\u003eThe \u003cstrong data-start=\"945\" data-end=\"982\"\u003eKYORITSU 2001A Digital Multimeter\u003c\/strong\u003e is a high-precision instrument designed for safe and accurate AC\/DC current and voltage measurements up to 600V. Featuring an integrated AC\/DC clamp sensor, the KEW 2001A provides a compact, ergonomic design with a clear digital display and stable readings. Its portability and performance make the KYORITSU 2001A Digital Multimeter ideal for electricians, maintenance technicians, and engineers who need reliable measurements for fieldwork and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eVideo:\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/MUSXQhAcfEI\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/kewmate_img02_en.jpg?v=1733479327\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures up to 100A for both AC and DC currents with the OPEN CLAMP SENSOR.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Cable Protection:\u003c\/strong\u003e Features improved cable strength with robust protection for added durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Heavy Duty:\u003c\/strong\u003e Pocket-sized design combined with a heavy-duty build ensures portability without sacrificing strength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Probe Holster:\u003c\/strong\u003e Test probe can be securely fixed to the holster for convenient storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e Equipped with a test lead cap to prevent short circuit accidents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlim Clamp Jaws:\u003c\/strong\u003e Open jaws are thin enough to clamp wires in tight spaces, offering flexibility for hard-to-reach areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e340.0mV \/ 3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (50 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e100.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e100.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e340.0Ω \/ 3.400kΩ \/ 34.00kΩ \/ 340.0kΩ \/ 3.400MΩ \/ 34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (0 - 340kΩ); ±5%rdg ±5dgt (3.4MΩ); ±15%rdg ±5dgt (34MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 30 ±10Ω\u003c\/td\u003e\n\u003ctd\u003eWorks only on 340Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eAC A: 3.4Hz - 10kHz; AC V: 3.4Hz - 300kHz\u003c\/td\u003e\n\u003ctd\u003e±0.1%rdg ±1dgt (Current \u0026gt; 25A, Voltage \u0026gt; 30V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ10mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V \/ CAT II 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm × 92 mm × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (R03), instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eSoft carrying case (9107)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073137311956,"sku":"KE 2001A","price":996.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/85254bc6521e52f3fe7963ea757232d5.jpg?v=1770653850"},{"product_id":"kyoritsu-2300r-current-tester","title":"KYORITSU 2300R Current Tester | KEW 2300R AC\/DC Current Tester","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2300R Fork Current Tester\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"844\" data-end=\"882\"\u003e\u003cstrong data-start=\"847\" data-end=\"880\"\u003eKYORITSU 2300R Current Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"883\" data-end=\"1378\"\u003eThe \u003cstrong data-start=\"887\" data-end=\"920\"\u003eKYORITSU 2300R Current Tester\u003c\/strong\u003e is a high-precision instrument designed for safe and accurate AC\/DC current measurements using its fork-style design. The KEW 2300R features a compact, ergonomic structure, clear digital display, and stable readings, ensuring reliable and efficient operation. Its portability and performance make the KYORITSU 2300R Current Tester ideal for electricians, maintenance technicians, and engineers who require precise current measurement in daily field tasks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Measurement:\u003c\/strong\u003e Delivers accurate readings for distorted waveforms caused by inverters and thyristors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Voltage Detection:\u003c\/strong\u003e Audible and visual alerts indicate the presence of AC voltage for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Adjustment Function:\u003c\/strong\u003e Allows quick and easy zeroing for DC current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Ideal for use in crowded connection boxes with limited space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power Off:\u003c\/strong\u003e Preserves battery life by turning off automatically after 10 minutes of inactivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e0 to 100.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt [50\/60Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e0 to ±100.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Contact Voltage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eDetects AC voltage without contact; \"Hi\" flashes, and a buzzer sounds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Digit Display\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e1,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø10mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 46 hours (AC A) \/ Approx. 52 hours (DC A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e161 mm × 40 mm × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 110g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9113), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083510644948,"sku":"KE 2300R","price":585.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/KEW_2300R.jpg?v=1773246727"},{"product_id":"kyoritsu-2127r-clamp-meter","title":"KYORITSU 2127R Clamp Meter | KEW 2127R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2127R AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"816\" data-end=\"851\"\u003e\u003cstrong data-start=\"819\" data-end=\"849\"\u003eKYORITSU 2127R Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"852\" data-end=\"1352\"\u003eThe \u003cstrong data-start=\"856\" data-end=\"886\"\u003eKYORITSU 2127R Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC current measurements in residential, commercial, and industrial electrical systems. The KEW 2127R features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2127R Clamp Meter ideal for electricians, maintenance technicians, and engineers who require precise AC current measurement in daily field tasks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Safety Jaw:\u003c\/strong\u003e Designed for secure and safe current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e Over-molded body allows convenient one-hand operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Backlit Display:\u003c\/strong\u003e Easy-to-read display with 0.01A resolution, ideal for low-light conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Auto-Ranging:\u003c\/strong\u003e Accurate measurements for 60A, 600A, and 1000A ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Hold Function:\u003c\/strong\u003e Captures inrush current for dynamic loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance and Diode Testing:\u003c\/strong\u003e Expands functionality for diverse applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Battery Life:\u003c\/strong\u003e Operates continuously for approximately 170 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Compliant with IEC 61010-1 CAT IV 300V \/ CAT III 600V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt [45 - 65Hz]; ±2.0%rdg ±5dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±2dgt [45 - 65Hz]; ±1.5%rdg ±4dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt (60V); ±1.2%rdg ±3dgt (600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ \/ 60.00kΩ \/ 600.0kΩ \/ 6.000MΩ \/ 40.00MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±5dgt (600Ω); ±2.0%rdg ±3dgt (6\/60\/600kΩ); ±3.0%rdg ±3dgt (6MΩ); ±5.0%rdg ±3dgt (40MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 90Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Test\u003c\/td\u003e\n\u003ctd\u003e1.000µF \/ 10.00µF \/ 100.0µF\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±15dgt (1µF); ±3.0%rdg ±10dgt (10\/100µF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e2.000V\u003c\/td\u003e\n\u003ctd\u003e±4%rdg ±5dgt (Open-circuit voltage: \u0026lt;3.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e999.9Hz \/ 9.999kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±0.1%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2 (EMC), IEC 60529 IP40, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 170 hours (NCV_LED, Backlight off; auto power save after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e204 mm × 81 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 230g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), carrying case (9079), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083515494612,"sku":"KE 2127R","price":986.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/f95fc1b97a1b933c1f8221eb54a39245.jpg?v=1770653856"},{"product_id":"kyoritsu-2056r-clamp-meter","title":"KYORITSU 2056R Clamp Meter | KEW 2056R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2056R AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"706\" data-end=\"741\"\u003e\u003cstrong data-start=\"709\" data-end=\"739\"\u003eKYORITSU 2056R Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"742\" data-end=\"1261\"\u003eThe \u003cstrong data-start=\"746\" data-end=\"776\"\u003eKYORITSU 2056R Clamp Meter\u003c\/strong\u003e is a high-precision instrument designed for safe and accurate AC\/DC current measurements in residential, commercial, and industrial electrical systems. The KEW 2056R features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable and efficient operation. Its portability and performance make the KYORITSU 2056R Clamp Meter ideal for electricians, maintenance technicians, and engineers who require precise current measurement in daily field tasks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Voltage Detection:\u003c\/strong\u003e Red LED warns of the presence of AC voltage for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-Molded Ergonomic Design:\u003c\/strong\u003e Provides a secure and comfortable grip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurement Capabilities:\u003c\/strong\u003e Supports AC\/DC current, AC\/DC voltage, resistance, continuity, capacitance, temperature, and frequency measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Range:\u003c\/strong\u003e Measures AC\/DC currents up to 1000A with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT IV 600V for secure and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600mV \/ 6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (600Ω - 6MΩ); ±5%rdg ±8dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds at 100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e400nF \/ 4μF \/ 40μF (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-50°C to +300°C (with Temperature Probe 8216)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz \/ 100Hz \/ 1kHz \/ 10kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1% - 99.9%\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ40mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V; IEC 61010-031; IEC 61010-2-032; IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e254 mm × 82 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 310g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), carrying case (9094), instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eTemperature probe (8216)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083517362388,"sku":"KE 2056R","price":1606.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/20220829085801c84bf26c8ae089c4daedbf09e022026b.jpg?v=1770655078"},{"product_id":"kyoritsu-2055-clamp-meter","title":"KYORITSU 2055 Clamp Meter – AC\/DC Digital KEW 2055","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2055 AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"700\" data-end=\"734\"\u003e\u003cstrong data-start=\"703\" data-end=\"732\"\u003eKYORITSU 2055 Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"735\" data-end=\"1251\"\u003eThe \u003cstrong data-start=\"739\" data-end=\"768\"\u003eKYORITSU 2055 Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC\/DC current measurements in residential, commercial, and industrial electrical systems. The KEW 2055 features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable and efficient operation. Its portability and performance make the KYORITSU 2055 Clamp Meter ideal for electricians, maintenance technicians, and engineers who require precise current measurement in daily field operations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Voltage Detection:\u003c\/strong\u003e Red LED provides a clear warning of AC voltage presence for added safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e Double molding ensures comfort during prolonged use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measurement Range:\u003c\/strong\u003e Capable of measuring up to 1000A AC\/DC with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurements:\u003c\/strong\u003e Supports AC\/DC current, AC\/DC voltage, resistance, continuity, and frequency testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT IV 600V for secure operation in high-risk environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (50\/60Hz); ±3.0%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±4dgt (50\/60Hz); ±3.0%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600mV \/ 6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (600Ω - 6MΩ); ±5%rdg ±8dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds at 100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz \/ 100Hz \/ 1kHz \/ 10kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1% - 99.9%\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ40mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V, IEC 61010-031, IEC 61010-2-032, IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e254 mm × 82 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 310g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), carrying case (9094), instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083522670804,"sku":"KE 2055","price":1146.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/f16aae8caac92ad75359c4ef241706d9.jpg?v=1770653871"},{"product_id":"kyoritsu-2046r-clamp-meter","title":"KYORITSU 2046R Clamp Meter – AC\/DC Digital KEW 2046R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2046R AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"729\" data-end=\"764\"\u003e\u003cstrong data-start=\"732\" data-end=\"762\"\u003eKYORITSU 2046R Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"765\" data-end=\"1259\"\u003eThe \u003cstrong data-start=\"769\" data-end=\"799\"\u003eKYORITSU 2046R Clamp Meter\u003c\/strong\u003e is a high-precision instrument designed for safe and accurate AC\/DC current measurements in residential, commercial, and industrial electrical systems. The KEW 2046R features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2046R Clamp Meter ideal for electricians, technicians, and engineers who require precise current measurement for daily field tasks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Voltage Detection:\u003c\/strong\u003e Red LED alerts the user to the presence of AC voltage for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble Molding Design:\u003c\/strong\u003e Ensures a comfortable grip during prolonged use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurement Functions:\u003c\/strong\u003e Measures AC\/DC current, AC\/DC voltage, resistance, continuity, capacitance, temperature, and frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Offers a minimum resolution of 0.1A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT IV 600V for secure and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600mV \/ 6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (600Ω - 6MΩ); ±5%rdg ±8dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e400nF \/ 4μF \/ 40μF (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-50°C to +300°C (with Temperature Probe 8216)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz \/ 100Hz \/ 1kHz \/ 10kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1% - 99.9%\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V; IEC 61010-031; IEC 61010-2-032; IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e243 mm × 77 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 300g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), carrying case (9094), instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eTemperature probe (8216)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083524571348,"sku":"KE 2046R","price":1373.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/bda689632f1ddf992f92cb24650fc939.jpg?v=1770653870"},{"product_id":"kyoritsu-2033-clamp-meter","title":"KYORITSU 2033 Clamp Meter– AC\/DC Digital KEW 2033","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2033 AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"764\" data-end=\"800\"\u003e\u003cstrong data-start=\"769\" data-end=\"798\"\u003eKYORITSU 2033 Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"801\" data-end=\"1122\"\u003eThe \u003cstrong data-start=\"805\" data-end=\"834\"\u003eKYORITSU 2033 Clamp Meter\u003c\/strong\u003e is designed for precise AC\/DC current measurements in residential, commercial, and industrial settings. Compact and lightweight, it ensures safe, reliable readings for electricians, technicians, and maintenance professionals. Its ergonomic design provides comfort during prolonged use.\u003c\/p\u003e\n\u003ch4 data-start=\"1124\" data-end=\"1143\"\u003e \u003c\/h4\u003e\n\u003ch4 data-start=\"1049\" data-end=\"1068\"\u003e\u003cstrong data-start=\"1054\" data-end=\"1066\"\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1069\" data-end=\"1268\"\u003eThe KYORITSU 2033 delivers fast and reliable readings, featuring high accuracy, easy-to-read digital display, and robust safety compliance. Its ergonomic design ensures comfort during extended use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall and Lightweight:\u003c\/strong\u003e Compact design for ease of handling and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures currents up to 300A with high precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-Ranging Function:\u003c\/strong\u003e Automatically adjusts to the optimal range for accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Adjustment Button:\u003c\/strong\u003e Allows quick and easy DC current zeroing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Complies with IEC 61010-1 CAT III 300V for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40A \/ 300A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±4dgt [50\/60Hz] (0 - 40A); ±2.5%rdg ±4dgt [20Hz - 1kHz] (0 - 40A); ±1.5%rdg ±4dgt [50\/60Hz] (20 - 200A); ±2.5%rdg ±4dgt [20Hz - 1kHz] (20 - 200A); ±3.5%rdg [50\/60Hz] (200 - 300A); ±4%rdg [20Hz - 1kHz] (200 - 300A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e40A \/ 300A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±4dgt (0 - ±40A); ±1.5%rdg ±4dgt (±20 - ±200A); ±3%rdg (±200 - ±300A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC, 20Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ24mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × LR44 (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e147 mm × 59 mm × 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9090), 2 × LR44 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083526504660,"sku":"KE 2033","price":1249.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/80ca72362a87dc813b78a30c1ae95365.jpg?v=1770653870"},{"product_id":"kyoritsu-2500-dc-milliamp-clamp-meter","title":"KYORITSU 2500 DC Milliamp Clamp Meter – KEW 2500","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2500 DC Milliamp Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"808\" data-end=\"856\"\u003eKYORITSU \u003cstrong data-start=\"813\" data-end=\"854\"\u003e2500 DC Milliamp Clamp Meter\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"857\" data-end=\"1383\"\u003eThe \u003cstrong data-start=\"861\" data-end=\"902\"\u003eKYORITSU 2500 DC Milliamp Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate DC milliampere measurement in residential, commercial, and industrial electrical systems. The \u003cstrong data-start=\"1054\" data-end=\"1066\"\u003eKEW 2500\u003c\/strong\u003e features a compact, ergonomic design and a clear digital display, ensuring reliable and stable readings. Its portability and performance make the \u003cstrong data-start=\"1213\" data-end=\"1254\"\u003eKYORITSU 2500 DC Milliamp Clamp Meter\u003c\/strong\u003e ideal for electricians, engineers, and maintenance technicians requiring precise current measurements in daily field operations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eVideo :\u003cbr\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/NS49A2aZN3A\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e \u003cbr\u003eKey Features:\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Measurement accuracy of ±0.2% for 0.00 to 21.49mA and ±1.0% for 21.0 to 120.0mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Jaw Design:\u003c\/strong\u003e ∅6mm clamp jaws make it easy to work in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Display:\u003c\/strong\u003e Backlit display shows both milliamp measurement and percentage of 4-20mA span simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpotlight LED:\u003c\/strong\u003e Illuminates the measurement point for convenience in low-light conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Terminal:\u003c\/strong\u003e Outputs DC voltage for recorder or logger connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Design:\u003c\/strong\u003e Complies with IEC 61010-1 safety standards, ensuring reliability and safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 100mA\u003c\/td\u003e\n\u003ctd\u003e±0.2%rdg ±5dgt (0.00 - 21.49mA); ±1.0%rdg ±5dgt (21.0 - 120.0mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e10mV\/mA\u003c\/td\u003e\n\u003ctd\u003eOutput impedance approx. 5kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax ∅6mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, IEC 61010-2-032, IEC 61326-1, IEC 60529 IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd\u003e-10 to +50℃; RH ≤ 85% (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e4 × R6 (AA) batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eApprox. 60 hours (with LED off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e111(L) × 61(W) × 40(D)mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 290g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying Case (MODEL 9096), 4 × R6 (AA) batteries, Instruction Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Cord (MODEL 7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083543052500,"sku":"KE 2500","price":2664.1,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/537a5f685a0a36c1240b7ea3497a813b.jpg?v=1770653872"},{"product_id":"kyoritsu-2432-leakage-clamp-meter","title":"KYORITSU 2432 Leakage Clamp Meter | KEW 2432","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2432 Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"806\" data-end=\"850\"\u003e\u003cstrong data-start=\"811\" data-end=\"848\"\u003eKYORITSU 2432 Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"851\" data-end=\"1395\"\u003eThe \u003cstrong data-start=\"855\" data-end=\"892\"\u003eKYORITSU 2432 Leakage Clamp Meter\u003c\/strong\u003e is a professional-grade instrument designed for accurate leakage current measurement in residential, commercial, and industrial electrical systems. The \u003cstrong data-start=\"1045\" data-end=\"1057\"\u003eKEW 2432\u003c\/strong\u003e features an ergonomic design, easy-to-read digital display, and stable readings for safe and reliable operation. Its compact size and high performance make the \u003cstrong data-start=\"1218\" data-end=\"1255\"\u003eKYORITSU 2432 Leakage Clamp Meter\u003c\/strong\u003e a must-have tool for electricians, maintenance technicians, and engineers requiring precise current measurements in daily field operations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Reduces harmonic effects for precise measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Measurement Ranges:\u003c\/strong\u003e 4mA, 40mA, and 100A to cover diverse applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.001mA for detecting minute leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates effectively across 20Hz to 1kHz (40Hz to 1kHz for 100A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for safe and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e4mA \/ 40mA \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (4\/40mA); ±1%rdg ±5dgt (0 - 80A); ±5%rdg (80.1 - 100A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e4mA \/ 40mA \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt [50\/60Hz]; ±2.5%rdg ±10dgt [20Hz - 1kHz] (4\/40mA); ±1%rdg ±5dgt [50\/60Hz]; ±2.5%rdg ±10dgt [40Hz - 1kHz] (0 - 80A); ±5%rdg [50\/60Hz]; ±10%rdg [40Hz - 1kHz] (80.1 - 100A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC (Line\/Neutral); 300V AC\/DC (Earth)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø40mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eApprox. 2mA AC near a 15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz - 1kHz (40Hz - 1kHz for 100A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm × 81 mm × 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 290g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9097), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083543249108,"sku":"KE 2432","price":3010.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/a20edf7b57e290a76f192505dfb2d11b.jpg?v=1770653877"},{"product_id":"kyoritsu-2413f-leakage-digital-clamp-meter","title":"KYORITSU 2413F Leakage Digital Clamp Meter | KEW 2413F","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2413F Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"832\" data-end=\"885\"\u003e\u003cstrong data-start=\"837\" data-end=\"883\"\u003eKYORITSU 2413F Leakage Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"886\" data-end=\"1483\"\u003eThe \u003cstrong data-start=\"890\" data-end=\"936\"\u003eKYORITSU 2413F Leakage Digital Clamp Meter\u003c\/strong\u003e is a high-precision instrument designed to measure leakage current safely and accurately in residential, commercial, and industrial electrical systems. The \u003cstrong data-start=\"1093\" data-end=\"1106\"\u003eKEW 2413F\u003c\/strong\u003e features a compact, ergonomic design with true RMS measurement capability, ensuring stable and reliable readings. With its easy-to-read digital display, the \u003cstrong data-start=\"1264\" data-end=\"1310\"\u003eKYORITSU 2413F Leakage Digital Clamp Meter\u003c\/strong\u003e is ideal for electricians, maintenance technicians, and installation professionals who require dependable performance and precise current measurement in everyday field use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Transformer Jaws:\u003c\/strong\u003e Measures leakage current in 3-phase systems with ease.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Filter Switch:\u003c\/strong\u003e Minimizes harmonic interference for accurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Way Analog Output:\u003c\/strong\u003e Supports waveform and recorder connections for data logging and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Handles currents up to 1000A with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for secure and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt (200mA \/ 2A \/ 20A); ±2%rdg ±2dgt (200A, 0 - 500A); ±5.5%rdg (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt [50\/60Hz], ±3%rdg ±2dgt [40Hz - 1kHz] (200mA \/ 2A \/ 20A); ±1.5%rdg ±2dgt [50\/60Hz], ±3.5%rdg ±2dgt [40Hz - 1kHz] (200A, 0 - 500A); ±5%rdg [50\/60Hz], ±10%rdg [40Hz - 1kHz] (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø68mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003eφ15mm 100A\u003c\/td\u003e\n\u003ctd\u003e10mA AC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOutput Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform Output\u003c\/td\u003e\n\u003ctd\u003eAC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003eDC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e1 × 6F22 (9V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 60 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 130 mm × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 570g (including battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9094), 1 × 6F22 (9V) battery, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e2WAY Output Cord (7073)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083543281876,"sku":"KE 2413F","price":2878.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/cad6207fcab04c7ee67d2ca0af8756c5.jpg?v=1770653877"},{"product_id":"kyoritsu-4200-earth-clamp-tester","title":"KYORITSU 4200 Earth Clamp Tester | KEW 4200","description":"\u003ch1 class=\"goods_name\"\u003eEARTH CLAMP TESTER - MODEL 4200\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"629\" data-end=\"674\"\u003e\u003cstrong data-start=\"632\" data-end=\"672\"\u003eKYORITSU 4200 Earth Clamp Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"675\" data-end=\"1048\"\u003eThe \u003cstrong data-start=\"679\" data-end=\"715\"\u003eKYORITSU 4200 earth clamp tester\u003c\/strong\u003e is engineered for precise ground resistance measurement without disconnecting the grounding system. The \u003cstrong data-start=\"820\" data-end=\"856\"\u003eKYORITSU 4200 earth clamp tester\u003c\/strong\u003e ensures safe, reliable, and efficient readings, making it an essential tool for electricians, engineers, and maintenance professionals in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/4200-method_en.png?v=1733660491\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measuring Range:\u003c\/strong\u003e Measures earth resistance from 0.05Ω to 1500Ω, ideal for multi-earthing systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Measurement:\u003c\/strong\u003e Leakage and phase current readings from 0.1mA to 30.0A for detailed analysis of earthing networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e Filter function reduces the impact of electrical noise, with a noise mark to indicate high levels of interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Function:\u003c\/strong\u003e Stores up to 100 data points for later retrieval and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Range Indication:\u003c\/strong\u003e Displays \"OL\" when the input exceeds the upper limit of a measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Provides up to 12 hours of operation using R6 batteries or 24 hours with LR6 batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power Off:\u003c\/strong\u003e Automatically powers off the device after 10 minutes of inactivity to conserve battery life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Resistance (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e20.00Ω \/ 200.0Ω \/ 1500Ω\u003c\/td\u003e\n\u003ctd\u003e±1.5% ±0.05Ω (0.00 - 20.99Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% ±0.5Ω (16.0 - 99.9Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e±3% ±2Ω (100.0 - 209.9Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (50\/60Hz, Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e100.0mA \/ 1000mA \/ 10.00A \/ 30.0A\u003c\/td\u003e\n\u003ctd\u003e±2% ±0.7mA (0.0 - 104.9mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% (80mA - 31.5A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-Range Indication\u003c\/td\u003e\n\u003ctd\u003eDisplays \"OL\" when the input exceeds the upper limit of the measurement range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 7 seconds for Earth resistance, approx. 2 seconds for AC current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Rate\u003c\/td\u003e\n\u003ctd\u003eApprox. 1 time per second.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 50mA (max. 100mA).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 12 hours with R6 batteries, approx. 24 hours with LR6 batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eApprox. Ø32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V Pollution degree 2, IEC 61010-2-032, IEC 61326 (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eLR6\/R6 (AA) (1.5V) × 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e246(L) × 120(W) × 54(D)mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 780g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e8304 (Resistor for operation check)\u003c\/li\u003e\n\u003cli\u003e9166 (Carrying case [Hard])\u003c\/li\u003e\n\u003cli\u003eR6 × 4, Instruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083579818196,"sku":"KE 4200","price":5605.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/KE_4200.jpg?v=1773246728"},{"product_id":"kyoritsu-2117r-ac-clamp-meter","title":"Kyoritsu 2117R Digital Clamp Meter - True RMS 1000A AC Auto-Ranging","description":"\u003cdiv\u003e\n\u003ch1 data-end=\"1197\" data-start=\"1143\"\u003eKYORITSU 2117R Digital AC Clamp Meter with True-RMS : The 1000A Gold Standard\u003c\/h1\u003e\n\u003ch2 data-path-to-node=\"3\"\u003ePrecision Amperage for the Modern Pro\u003c\/h2\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-index-in-node=\"4\" data-path-to-node=\"4\"\u003eKyoritsu 2117R\u003c\/b\u003e is the go-to \"workhorse\" for \u003cb data-index-in-node=\"48\" data-path-to-node=\"4\"\u003eelectricians, HVAC engineers, and industrial maintenance teams\u003c\/b\u003e. Built to handle high-demand environments, it allows you to measure up to 1000A AC safely without interrupting the circuit. Whether you are troubleshooting industrial motors or complex commercial panels, this True RMS meter ensures accuracy even in the presence of electronic noise and harmonics.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"5\"\u003eTop Irresistible Features\u003c\/h2\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003e1000A True RMS Power:\u003c\/b\u003e Get 100% accurate readings on non-sinusoidal loads like LED systems and motor inverters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eIntegrated NCV Sensor:\u003c\/b\u003e Built-in Non-Contact Voltage detection for instant safety checks before you touch any wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003eSlim Tear-Drop Jaws:\u003c\/b\u003e 33mm ergonomic shape designed specifically to reach into tight, crowded cable bundles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003eOne-Handed Operation:\u003c\/b\u003e Ultra-light, over-molded body provides a secure, comfortable grip for all-day field use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,4,0\"\u003eExtreme Battery Life:\u003c\/b\u003e Up to 170 hours of continuous use—nearly triple the industry standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eVideo:\u003cbr\u003e\u003ciframe height=\"315\" width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/RKfTjloDrZM\"\u003e\u003c\/iframe\u003e \u003c\/h2\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable cellpadding=\"5\" border=\"1\" style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt [45 - 65Hz]; ±2.0%rdg ±5dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±2dgt [45 - 65Hz] (600V); ±1.5%rdg ±4dgt [40Hz - 1kHz] (60\/600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt (60V); ±1.2%rdg ±3dgt (600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ \/ 60.00kΩ \/ 600.0kΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±5dgt (600Ω); ±2.0%rdg ±3dgt (6\/60\/600kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 90Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable cellpadding=\"5\" border=\"1\" style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2 (EMC), IEC 60529 IP 40, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 170 hours (NCV_LED off; auto power save after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e204 mm × 81 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7066A), carrying case (9079), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eThailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 data-path-to-node=\"11\"\u003eWhat’s Inside the Box?\u003c\/h2\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003eKyoritsu 2117R Digital Clamp Meter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e7066A Professional Test Leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e9079 Heavy-Duty Carrying Case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e2 x AAA Batteries (R03)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\"\u003eComprehensive Instruction Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"14\"\u003eWhy Choose Kyoritsu \u0026amp; This Model?\u003c\/h2\u003e\n\u003cp data-path-to-node=\"15\"\u003eKyoritsu is a world leader in Japanese testing technology. Users choose the \u003cb data-index-in-node=\"76\" data-path-to-node=\"15\"\u003e2117R\u003c\/b\u003e because it is the \"De Facto\" standard for durability. While most clamp meters are bulky, this model combines a high 1000A capacity with a slim, ergonomic frame that is virtually indestructible in industrial settings.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"16\"\u003eWarranty \u0026amp; Support\u003c\/h2\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e1-Year Limited Warranty. \u003cstrong\u003eCovers\u003c\/strong\u003e all manufacturing defects, electronic board failures, and internal calibration errors. However, it \u003cstrong\u003edoes not cover\u003c\/strong\u003e consumable leads, battery leakage, blown fuses, or physical damage from drops beyond rated limits.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083598528724,"sku":"KE 2117R","price":418.7,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu_2117r_01.png?v=1775838602"},{"product_id":"kyoritsu-2002pa-digital-clamp-meter","title":"KYORITSU 2002PA Digital AC Clamp Meter | KEW 2002PA","description":"\u003ch1 class=\"goods_name\"\u003eKYORITSU 2002PA AC Digital Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2002PA digital clamp meter\u003c\/strong\u003e is a precision instrument for measuring AC current without disconnecting circuits. The \u003cstrong\u003eKYORITSU 2002PA digital clamp meter\u003c\/strong\u003e ensures safe, reliable, and accurate readings for electricians, engineers, and maintenance personnel in industrial, commercial, and residential applications.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/27db10f7d1e062c41c5703ce43814177_c025c159-f96a-4b6f-ac7f-cb31cb1c1a64.jpg?v=1763291899\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Capable of measuring AC currents up to 2000A with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Hold Function:\u003c\/strong\u003e Captures transient peak values for accurate measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Tear Drop Shaped Jaws:\u003c\/strong\u003e φ55mm jaws are designed for easy clamping of thick conductors in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Minimum resolution of 0.1A ensures precision even in low-current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e The clamp meter is compact yet powerful, perfect for industrial and fieldwork use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e400A (0 - 400A)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (50\/60Hz); ±2%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (0 - 1500A)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (50\/60Hz); ±3%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (1500 - 2000A)\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (AC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt (50\/60Hz); ±1.5%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400Ω \/ 4kΩ \/ 40kΩ \/ 400kΩ\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e2.000V\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±5dgt (Open-circuit voltage: approx. 2.7V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance (F)\u003c\/td\u003e\n\u003ctd\u003e400.0nF \/ 4.000µF \/ 40.00µF\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±10dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eAC A: 99.99Hz \/ 400Hz; AC V: 99.99Hz \/ 999.9Hz \/ 9.999kHz \/ 99.99kHz \/ 300.0kHz\u003c\/td\u003e\n\u003ctd\u003e±0.2%rdg ±2dgt (100Hz); ±0.1%rdg ±1dgt (1000Hz \/ 10kHz \/ 300kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ55mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e247 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7107A), carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083598725332,"sku":"KE 2002PA","price":1140.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/56ce810c71953bd8ea15fd09b7e4c964.jpg?v=1770653972"},{"product_id":"kyoritsu-4202-digital-earth-clamp-tester","title":"KYORITSU 4202 Digital Earth Clamp Tester | KEW 4202","description":"\u003ch1 class=\"goods_name\"\u003eEARTH CLAMP TESTER - KEW 4202\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"1141\" data-end=\"1192\"\u003e\u003cstrong data-start=\"1144\" data-end=\"1192\"\u003eKYORITSU 4202 Digital Earth Clamp Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1193\" data-end=\"1538\"\u003eThe \u003cstrong data-start=\"1197\" data-end=\"1241\"\u003eKYORITSU 4202 digital earth clamp tester\u003c\/strong\u003e is a high-precision instrument designed to measure ground resistance without disconnecting the earth system. The \u003cstrong data-start=\"1355\" data-end=\"1399\"\u003eKYORITSU 4202 digital earth clamp tester\u003c\/strong\u003e provides reliable readings for electricians, engineers, and maintenance personnel in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003ch2 data-start=\"1866\" data-end=\"1881\"\u003e\u003cstrong data-start=\"1869\" data-end=\"1881\"\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1882\" data-end=\"2321\"\u003eThe \u003cstrong data-start=\"1886\" data-end=\"1930\"\u003eKYORITSU 4202 digital earth clamp tester\u003c\/strong\u003e allows accurate ground resistance measurement without the need to disconnect the earth system. Its portable design and high-precision capability make it ideal for field inspections, maintenance, and electrical safety audits. This tester is durable, easy to use, and compatible with a wide range of industrial and commercial applications, ensuring efficient and safe measurements every time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/4200-method_en.png?v=1733660491\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measuring Range:\u003c\/strong\u003e Measures earth resistance from 0.05Ω to 1500Ω, suitable for multi-earthing systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Measurement:\u003c\/strong\u003e Provides leakage and phase current readings from 0.1mA to 30.0A for comprehensive analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e The filter function helps reduce the impact of electrical noise, with a noise mark indicating excessive interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Function:\u003c\/strong\u003e Stores up to 100 data sets for later retrieval and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBluetooth® Connectivity:\u003c\/strong\u003e Easily syncs with the \"KEW smart 4202\" app available on the Google Play Store, enabling convenient data transfer to Android devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Range Indication:\u003c\/strong\u003e Displays \"OL\" when the input exceeds the upper limit of the measuring range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power Off:\u003c\/strong\u003e Automatically powers off the device after 10 minutes of inactivity to conserve battery life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Resistance (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e20.00Ω \/ 200.00Ω \/ 1500Ω\u003c\/td\u003e\n\u003ctd\u003e±1.5% ±0.05Ω (0.00 - 20.99Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% ±0.5Ω (16.0 - 99.9Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e±3% ±2Ω (100.0 - 209.9Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (50Hz\/60Hz, Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e100.0mA \/ 1000mA \/ 10.00A \/ 30.0A\u003c\/td\u003e\n\u003ctd\u003e±2% ±0.7mA (0.0 - 104.9mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% (80mA - 31.5A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-Range Indication\u003c\/td\u003e\n\u003ctd\u003eDisplays \"OL\" when the input exceeds the upper limit of the measurement range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 7 seconds for Earth resistance, approx. 2 seconds for AC current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Rate\u003c\/td\u003e\n\u003ctd\u003eApprox. 1 time per second.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 50mA (max. 100mA).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 5 hours with R6 batteries, approx. 21 hours with LR6 batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eApprox. Ø32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V Pollution degree 2, IEC 61010-2-032, IEC 61326 (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eLR6\/R6 (AA) (1.5V) × 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e246(L) × 120(W) × 54(D)mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 780g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e8304 (Resistor for operation check)\u003c\/li\u003e\n\u003cli\u003e9167 (Carrying case [Hard])\u003c\/li\u003e\n\u003cli\u003eR6 × 4, Instruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKEW Smart 4202 Application\u003c\/h2\u003e\n\u003cp\u003eThe \"KEW Smart 4202\" application is available for free on the \u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.kewtech.keWSmart4202\"\u003eGoogle Play Store\u003c\/a\u003e. This app allows you to manage data from the KEW 4202 Earth Clamp Tester via Bluetooth and visualize readings on your Android device. It supports Android versions 8 to 15 and requires WVGA resolution (800 × 480) or higher and a GPS function. Communication charges may apply separately for downloading the app.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43442990547156,"sku":"KE 4202","price":6924.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/20221026061038faafcedf4986cd5afb1090298ae6cb76.png?v=1773245070"},{"product_id":"kyoritsu-2204r-ac-clamp-meter","title":"KYORITSU 2204R AC clamp meter","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2204R AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-end=\"1173\" data-start=\"1125\"\u003e\u003cstrong data-end=\"1173\" data-start=\"1128\"\u003eKYORITSU 2204R AC Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1464\" data-start=\"1174\"\u003eThe \u003cstrong data-end=\"1211\" data-start=\"1178\"\u003eKYORITSU 2204R AC clamp meter\u003c\/strong\u003e is a high-precision instrument designed for AC current measurement. The \u003cstrong data-end=\"1317\" data-start=\"1284\"\u003eKYORITSU 2204R AC clamp meter\u003c\/strong\u003e ensures reliable and safe readings for electricians, engineers, and maintenance personnel in industrial, commercial, and residential applications.\u003c\/p\u003e\n\u003cp data-end=\"1464\" data-start=\"1174\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/my-11134207-23030-7bl1yeg4yxov7f.jpg?v=1763289788\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible and Lightweight Clamp Sensor:\u003c\/strong\u003e Easy to use in tight or complex spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS:\u003c\/strong\u003e Delivers accurate measurements even for non-linear waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMIN\/MAX Function:\u003c\/strong\u003e Captures the minimum and maximum current values for dynamic loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit LCD Display:\u003c\/strong\u003e Ensures clear visibility in low-light environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Complies with IEC 61010-1 CAT IV 600V \/ CAT III 1000V for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e Offers a resolution of 0.001A for detailed measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable cellpadding=\"5\" border=\"1\" style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e4.000A \/ 40.00A \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±3%rdg ±5dgt [45 - 500Hz] (At the center of the circle formed by the flexible sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003eFull scale CF \u0026lt;1.6; half scale CF \u0026lt;3.2\u003c\/td\u003e\n\u003ctd\u003eEffective input crest values are √2 times the max values of each range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ70mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfluence of Conductor Position\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAdditional ±2% (max.) depending on the distance from the center position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e500A AC for 10 seconds\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable cellpadding=\"5\" border=\"1\" style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, IEC 61010-2-032 CAT IV 600V \/ CAT III 1000V, Pollution Degree 2, IEC 61326-1 (EMC), IEC 60529 IP40, EN50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature and Humidity Range\u003c\/td\u003e\n\u003ctd\u003e0 - +50°C; relative humidity 80% or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature and Humidity Range\u003c\/td\u003e\n\u003ctd\u003e-10 - +60°C; relative humidity 70% or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 120 hours (auto power off after approx. 15 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm × 70 mm × 26 mm (Display unit); φ5.5mm (Cable diameter); 1.8m (Cable length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 200g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9174), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43689403154644,"sku":"KE 2204R","price":1585.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/my-11134207-23030-7bl1yeg4yxov7f.jpg?v=1773245166"},{"product_id":"kyoritsu-2510-dc-clamp-logger","title":"KYORITSU 2510 DC Milliamp Clamp Logger KEW2510","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2510 DC Milliamp Clamp Logger\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eKYORITSU 2510 DC Milliamp Clamp Logger\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2510 DC clamp logger\u003c\/strong\u003e is designed for accurate DC milliamp measurements and logging. The \u003cstrong\u003eKYORITSU 2510 DC clamp logger\u003c\/strong\u003e ensures reliable current monitoring for electricians, engineers, and maintenance personnel in industrial and commercial applications.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/my-11134207-23030-a4w3ywtfzxovee.jpg?v=1763289631\" alt=\"\"\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Offers a resolution of 0.01mA for precise DC current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Accuracy:\u003c\/strong\u003e Measurement accuracy of ±0.2% for 0.00 to 21.49mA and ±1.0% for 21.0 to 120.0mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Jaw Design:\u003c\/strong\u003e ∅6mm clamp jaw fits easily in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Measures currents from 0.01 to 120.0mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Display:\u003c\/strong\u003e Backlit display shows both measured value (mA) and percentage value of the 4-20mA span.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpotlight LED:\u003c\/strong\u003e Illuminates measurement points for better visibility in low-light environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Function:\u003c\/strong\u003e Stores up to 192,000 records for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBluetooth Connectivity:\u003c\/strong\u003e Transfer measurement data to a PC wirelessly using Bluetooth® 5.0.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Terminal:\u003c\/strong\u003e Outputs DC voltage for connection to recorders or loggers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 100mA\u003c\/td\u003e\n\u003ctd\u003e±0.2%rdg ±5dgt (0.00 - 21.49mA); ±1.0%rdg ±5dgt (21.0 - 120.0mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax ∅6mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC1000mV against DC100mA\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 Pollution Degree 2; IEC 61010-2-032; IEC 61326-1 (EMC); IEC 60529 IP40; EN50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd\u003e-10 to +50°C; RH ≤ 85% (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd\u003e-20 to +60°C; RH ≤ 85% (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e4 × R6\/LR6 (AA) batteries (Alkaline LR6 recommended); External supply (AC adapter MODEL 8320)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eBluetooth® 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDisplay Unit: 111(L) × 61(W) × 46(D)mm; Sensor: 104(L) × 33(W) × 20(D)mm; Sensor Cable: 700mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 310g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e8320 (AC adapter), Carrying Case (9096), 4 × LR6 (AA) batteries, Instruction Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e7256 (Output cord)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43689422848212,"sku":"KE 2510","price":4749.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/my-11134207-23030-a4w3ywtfzxovee.jpg?v=1773245166"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/collections\/Kyoritsu_ac_clamp_meters_1280_x_720_px.png?v=1784714471","url":"https:\/\/techno.my\/collections\/kyoritsu-clamp-meters.oembed","provider":"Techno Tools \u0026 Equipment","version":"1.0","type":"link"}