{"title":"Clamp Meters","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eClamp meters allow \u003cstrong\u003esafe, fast measurement of AC\/DC current without breaking the circuit\u003c\/strong\u003e, making them essential for electricians and technicians working on live electrical systems across Malaysia. We carry \u003cstrong\u003e100% authentic\u003c\/strong\u003e models from \u003cstrong\u003eFluke, Hioki, Kyoritsu, Sanwa and UNI-T\u003c\/strong\u003e, backed by \u003cstrong\u003emanufacturer warranty\u003c\/strong\u003e. As an authorized distributor, Techno Tools \u0026amp; Equipment offers \u003cstrong\u003ecompetitive pricing and fast delivery\u003c\/strong\u003e across Malaysia, with \u003cstrong\u003esame-day delivery for Klang Valley customers\u003c\/strong\u003e.\u003cbr\u003e\u003c\/p\u003e","products":[{"product_id":"value-vmc-1-digital-clamp-meter","title":"VALUE VMC-1 Digital Clamp Meter for HVAC","description":"Model : VALUE DIGITAL MULTI CLAMP METER VMC-1\u003cbr\u003e\n\u003cbr\u003e\nFeatures :\u003cbr\u003e\n\u003cbr\u003e\nVMC-1 series are 4000-count hand-held clamp meters with auto range feature. The meter is designed with ergonomic structure and overload protection for each range, which makes it superior tool for electricians. VMC-1 series can measure AC\/DC voltage, AC current, resisance, diode, contiuity, capacitance, temperature and perform data hold, max\/min measurement, relative value measurement, NCV (non-contact voltage), low battery indication, auto\/visual alarm and auto power off functions.\u003cbr\u003e\n\u003cbr\u003e\nSpecification :\u003cbr\u003e\n\u003cbr\u003e\nLCD display max. disp. value 4099\u003cbr\u003e\nPolarity display automatic\u003cbr\u003e\nOverload display \"OL\" or \"-OL\"\u003cbr\u003e\nLow battery indication yes\u003cbr\u003e\nMeasurement deviation if the conductor being measured is not placed in the center of the jaw during current measurement, it will cause extra ±1.0% reading error.\u003cbr\u003e\nDrop test 1m drop test passed\u003cbr\u003e\nMax. jaw opening 28 mm\u003cbr\u003e\nMax. current conductor size 28 mm\u003cbr\u003e\nPower supply 2 x AAA 1.5V\u003cbr\u003e\nValue NAVTEK VMC-1 digital clamp multimeter\u003cbr\u003e\n\u003cbr\u003e\n- measures AC\/DC voltage, AC current, resitance, diode, °C\/°F temperature and others\u003cbr\u003e\n- automatic shut down function for energy saving\u003cbr\u003e\n- low battery alarm\u003cbr\u003e\n- 250V overload protection\u003cbr\u003e\n- maximum voltage measurement 600V\u003cbr\u003e\n- maximum AC current measurement 400A\u003cbr\u003e\n- temperature measurement range -40°C~1000°C","brand":"VALUE","offers":[{"title":"Default Title","offer_id":42969535938772,"sku":"VMC-1","price":122.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/eb8209732e1b460ed480cf8f0871154e_0eada9b1-c251-4740-b24d-10de39147b8b.jpg?v=1769148054"},{"product_id":"uni-t-ut202a-auto-ranging-ac-600-amp-clamp-meter","title":"UNI-T AC Clamp Meter 600A True RMS with NCV | UT202A+","description":"\u003cp\u003eThe UNI-T UT202A+ is a True RMS AC clamp meter that measures up to 600A AC through its 28mm jaw, with a 6000-count backlit display. It adds 600V AC\/DC voltage, resistance, 60mF capacitance, frequency, NCV and a neutral\/live wire test for everyday electrical work.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS\u003c\/strong\u003e — accurate readings on distorted waveforms from VFDs, LED drivers and switching loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e600A AC current\u003c\/strong\u003e — measure load current without breaking the circuit, through a 28mm jaw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6000-count backlit LCD\u003c\/strong\u003e — large digits that are easy to read in dim switchrooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60mF capacitance range\u003c\/strong\u003e — test large motor-start and power-factor capacitors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNCV and neutral\/live wire test\u003c\/strong\u003e — quickly confirm live conductors before work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto range, data hold, MAX\/MIN and relative mode\u003c\/strong\u003e — practical functions for faster fault finding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity and diode test\u003c\/strong\u003e — with low battery indication and auto power off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUT202A+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e600A, ±(2%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz–100Hz, ±(1%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e600V, ±(0.8%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage frequency\u003c\/td\u003e\n\u003ctd\u003e10Hz–10kHz, ±(1%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e600V, ±(0.5%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60MΩ, ±(0.8%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e60mF, ±(4%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz–10MHz, ±(0.1%+4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay count\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd\u003e28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNCV\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral\/live wire test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity \/ diode\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto range\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAX\/MIN, relative mode, data hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow battery indication \/ auto power off\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT II 600V \/ CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1.5V battery (R03\/AAA) × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD size\u003c\/td\u003e\n\u003ctd\u003e37mm × 25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e215mm × 63mm × 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e248g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUT202A+ clamp meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eCarrying bag\u003c\/li\u003e\n\u003cli\u003eEnglish user manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications \/ Ideal For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectricians checking load current on distribution boards and sub-circuits\u003c\/li\u003e\n\u003cli\u003eHVAC technicians testing compressors, fan motors and run\/start capacitors\u003c\/li\u003e\n\u003cli\u003eBuilding and facility maintenance teams\u003c\/li\u003e\n\u003cli\u003eIndustrial maintenance on motors, pumps and control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg width=\"524\" height=\"294\" src=\"https:\/\/meters.uni-trend.com\/storage\/2022\/04\/UT202BT-application.jpg\" alt=\"Clamp meter application\"\u003e\u003cimg width=\"524\" height=\"294\" src=\"https:\/\/meters.uni-trend.com\/storage\/2022\/04\/UT202T-application.jpg\" alt=\"Clamp meter application\"\u003e\u003c\/p\u003e\n\u003ch2\u003eWhy Buy from Techno Tools\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine UNI-T stock\u003c\/strong\u003e held in Malaysia\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast delivery nationwide\u003c\/strong\u003e, with same-day delivery in the Klang Valley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal warranty support\u003c\/strong\u003e from our team\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB2B friendly\u003c\/strong\u003e — quotations and invoices for companies and contractors\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":42970314703060,"sku":"UT 202A+","price":118.6,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/affd621b9ed870cecb201cf5b2478908.jpg?v=1769148214"},{"product_id":"proskit-mt-3102-3-1-2-2a-mini-digital-clamp-meter","title":"Pro'sKit Mini Digital Clamp Meter, 3½ Digit – MT-3102","description":"Model : PROSKIT MT-3102 3 1\/2 2A Mini Digital Clamp Meter\u003cbr\u003e\u003cbr\u003eDescription \u003cbr\u003e\u003cbr\u003eMT-3102 3 1\/2 mini digital clamp meter is a 3 1\/2-digit LCD multi-meter for measuring AC and DC voltage, AC current, resistance, temperature, Diode and continuity test. All overload protection is provided. The function\/range rotatable switch design makes manual operation workable, and range selector, power switch are all on one know. The select buttons for easy function change. It is ideal instrument for use in fields, factory, college and laboratory. \u003cbr\u003e\u003cbr\u003eFeatures \u003cbr\u003e\u003cbr\u003e3 1\/2 digits 1999 counts.\u003cbr\u003e0.8% best accuracy.\u003cbr\u003eAuto range.\u003cbr\u003ePortable and simple one-hand operation.\u003cbr\u003eExtra function: Maximum value hold, data hold, auto power off, low battery indication.\u003cbr\u003eMax. Jaw opening: max. 30mm.\u003cbr\u003e \u003cbr\u003eSpecifications\u003cbr\u003e \u003cbr\u003eDigits\u003cbr\u003e\u003cbr\u003e3 1\/2 digits 1999 counts\u003cbr\u003e\u003cbr\u003eAccuracy\u003cbr\u003e\u003cbr\u003e0.8% best accuracy\u003cbr\u003e\u003cbr\u003eDCV\u003cbr\u003e\u003cbr\u003e200mV ±(0.8%+5d), 2\/20\/200V ±(0.8%+3d),600V ±(1.0%+5d)\u003cbr\u003e\u003cbr\u003eACV\u003cbr\u003e\u003cbr\u003e2\/20\/200V ±(1.2%+5d),600V ±(1.5%+5d)\u003cbr\u003e\u003cbr\u003eACA\u003cbr\u003e\u003cbr\u003e2A ±(3.0%+15d) ≤ 0.4A ±(4.0%+20d),\u003cbr\u003e20A ±(2.0%+10d) ≤ 0.4A ±(3.0%+15d),\u003cbr\u003e200\/400A ± (2.0%+5d)\u003cbr\u003e\u003cbr\u003eResistance\u003cbr\u003e\u003cbr\u003e200Ω ±(1.2%+5d), 2k\/20k\/200kΩ ±(1.0%+3d), 2MΩ\u003cbr\u003e±(1.2%+5d), 20MΩ ±(1.5%+5d)\u003cbr\u003e\u003cbr\u003eTemperature\u003cbr\u003e\u003cbr\u003e-40~0?C ±(3.0%+4d), 0~400?C ±(1.0%+3d),\u003cbr\u003e400~1000?C ±(2.0%+10d)\u003cbr\u003e-40~32?F ±(3.0%+8d), 32~752?F ±(1.0%+6d),\u003cbr\u003e752~1832?F ±(2.0%+18d)\u003cbr\u003e\u003cbr\u003eExtra function\u003cbr\u003e\u003cbr\u003eMaximum value hold, data hold, auto power off,\u003cbr\u003elow battery indication\u003cbr\u003e\u003cbr\u003ePower Source\u003cbr\u003e\u003cbr\u003eAAA(1.5V) x 3 pcs (Not included)\u003cbr\u003e\u003cbr\u003eSize\u003cbr\u003e\u003cbr\u003e203 x 68 x 33 mm\u003cbr\u003e\u003cbr\u003eAccessories\u003cbr\u003e\u003cbr\u003eTest lead and thermocouple probe","brand":"PRO'SKIT","offers":[{"title":"Default Title","offer_id":42975298846932,"sku":"MT-3102","price":130.5,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/2d510e461f3ce5f51b5daacea9b8a68f_67d2134c-05b9-4e43-9456-e946d7165d3f.jpg?v=1769148563"},{"product_id":"proskit-mt-3109-ac-or-dc-digital-clamp-multimeter","title":"Pro'sKit AC\/DC Digital Clamp Meter, 3¾ Digit, 3999 Counts – MT-3109","description":"Model : PROSKIT MT-3109 AC or DC Digital Clamp Multimeter\u003cbr\u003e\u003cbr\u003eDescription\u003cbr\u003e \u003cbr\u003e\u003cbr\u003eMT-3109 features 2 jaws that clamp around an electrical conductor to measure the voltage on a line without having to make physical contact or disconnect the line for detection. Probes are also included for the user to test using the same manner as a traditional multimeter. It can also measure AC\/DC voltage and current, resistance, frequency, capacitance or tests diodes and continuity. The large LED display is ideal for clearly displaying values that are easy to read.\u003cbr\u003e\u003cbr\u003eFeatures\u003cbr\u003e \u003cbr\u003e\u003cbr\u003e3 3\/4 digits 3999 counts.\u003cbr\u003e1.0% best accuracy.\u003cbr\u003eAuto range.\u003cbr\u003eOverload protection.\u003cbr\u003eExtra function: duty cycle, relative reference, data Hold, sleep mode, auto power off, low battery indication.\u003cbr\u003eJaw Opening Size: max. 30mm\u003cbr\u003e \u003cbr\u003eSpecifications\u003cbr\u003e \u003cbr\u003e\u003cbr\u003eDigits\u003cbr\u003e\u003cbr\u003e3 3\/4 digits 3999 counts\u003cbr\u003e\u003cbr\u003eAccuracy\u003cbr\u003e\u003cbr\u003e1.0% best accuracy\u003cbr\u003e\u003cbr\u003eDCV\u003cbr\u003e\u003cbr\u003e400m\/4V ±(1.0%+3d), 40\/400V ±(1.0%+1d),600V ±(1.0%+5d)\u003cbr\u003e\u003cbr\u003eACV\u003cbr\u003e\u003cbr\u003e4\/40\/400V ±(1.2%+5d), 600V ±(1.5%+5d)\u003cbr\u003e\u003cbr\u003eDCA\u003cbr\u003e\u003cbr\u003e40A ±(2.5%+5d), 400A ±(2.5%+3d)\u003cbr\u003e\u003cbr\u003eACA\u003cbr\u003e\u003cbr\u003e40A ±(3.0%+8d), 400A ±(3.0%+5d)\u003cbr\u003e\u003cbr\u003eResistance\u003cbr\u003e\u003cbr\u003e400Ω ±(1.2%+5d), 4k\/40k\/400kΩ ±(1.0%+5d),\u003cbr\u003e4MΩ ±(1.2%+5d), 40MΩ ±(1.5%+5d\u003cbr\u003e\u003cbr\u003eFrequency\u003cbr\u003e\u003cbr\u003e10\/100\/1k\/10k\/100k\/1MHz ±(0.1%+5d),\u003cbr\u003e10MHz (For reference only)\u003cbr\u003e\u003cbr\u003eCapacitance\u003cbr\u003e\u003cbr\u003e40n\/400n\/4μ\/40μF ±(5.0%+10d), 100μF ±(6.0%+10d)\u003cbr\u003e\u003cbr\u003eExtra function\u003cbr\u003e\u003cbr\u003eDuty cycle, relative reference, data Hold, sleep mode,\u003cbr\u003eauto power off, low battery indication.\u003cbr\u003e\u003cbr\u003ePower Source\u003cbr\u003e\u003cbr\u003eAAA(1.5V) x 3 pcs (Not included)\u003cbr\u003e\u003cbr\u003eSize\u003cbr\u003e\u003cbr\u003e203 x 68 x 33 mm\u003cbr\u003e\u003cbr\u003eAccessories\u003cbr\u003e\u003cbr\u003eTest lead and alligator clips","brand":"PRO'SKIT","offers":[{"title":"Default Title","offer_id":42975301894356,"sku":"MT-3109","price":272.2,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/b1c6e4a70d76cc04c00972ca1e6f00b5_397ddb2c-cd58-404e-9656-229270f44e73.jpg?v=1769148565"},{"product_id":"proskit-mt-3110-smart-digital-clamp-meter","title":"Pro'sKit Smart Digital Clamp Meter, 5999 Counts, NCV – MT-3110","description":"PROSKIT MT-3110 Smart Digital Clamp Meter\u003cbr\u003e\u003cbr\u003e3 5\/6 Digital Smart Measurement\u003cbr\u003e\u003cbr\u003e3 5\/6 digits 5999 counts, 0.5% best accuracy\u003cbr\u003eAuto Selection of ACA,ACV,DCV,Resistance and Frequency\u003cbr\u003eAuto Range for convenient and accurate measurement\u003cbr\u003e​Simultaneous Measurement\u003cbr\u003e\u003cbr\u003eDual display enables you to display frequency while measuring AC Voltage, AC current; or while measuring AC Current simultaneously measure with AC\/DC Voltage and Resistance.\u003cbr\u003eNon contact ACV detector for AC 90-1000V AC peak current measurement\u003cbr\u003e\u003cbr\u003eDual Display with backlight allows operation in dark area. Display the results of simultaneous measurement\u003cbr\u003e\u003cbr\u003eExtra functions\u003cbr\u003e\u003cbr\u003eAuto power off, Low battery indication, Data hold\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eModel No. MT-3110\u003cbr\u003eACA 6A \/60A\/400A±(2.5%+8d)\u003cbr\u003e600A±(3.0%+10d)\u003cbr\u003ePEMAX: 900A ±(10%+10d)\u003cbr\u003eACV 6V \/60V\/600V ±(0.8%+5d)\u003cbr\u003eDCV 6V \/60V\/600V ±(0.5%+3d)\u003cbr\u003eResistance 6K\/60K\/600K\/6M\/10MΩ ±(0.8%+3d)\u003cbr\u003eFrequency 10~1kHz±(1.0%+5d),\u003cbr\u003eNCV(Non-Contact\u003cbr\u003eACV Detect) 90~1000V 50\/60Hz\u003cbr\u003eExtra functions Data hold, LCD backlight,\u003cbr\u003eLow Battery, Auto power off\u003cbr\u003eCertificate CE CAT III 600V\u003cbr\u003ePower Source 1.5V AAAx2 (not included)\u003cbr\u003eSize 190 x 68 x 38 mm","brand":"PRO'SKIT","offers":[{"title":"Default Title","offer_id":42975302549716,"sku":"MT-3110","price":180.5,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/873a6e5c12282708128ebc8651e216e3_d4746fdb-3c07-457d-9c90-bbbdd2631611.jpg?v=1769148571"},{"product_id":"sanwa-dcm400ad-clamp-meter","title":"Sanwa AC\/DC Clamp Meter, 400A, 600V, CAT III 300V – DCM400AD","description":"\u003cp\u003eThe \u003cstrong\u003eSANWA DCM400AD AC\/DC Digital Clamp Meter\u003c\/strong\u003e is a compact clamp meter for everyday electrical testing. Built for electricians, HVAC technicians and maintenance engineers, it measures AC and DC current up to 400A and AC\/DC voltage up to 600V, along with resistance and continuity.\u003c\/p\u003e\n\u003cp\u003eA 4000-count display with a fast 42-segment bar graph makes changing readings easy to follow, and the slim Φ25mm jaw fits around conductors in tight panels. The DCM400AD is rated to IEC61010 CAT III 300V \/ CAT II 600V.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC current up to 400A\u003c\/strong\u003e – one meter for AC and DC circuits\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAC\/DC voltage up to 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance \u0026amp; continuity\u003c\/strong\u003e – buzzer below approx. 40Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4000-count display with bar graph\u003c\/strong\u003e – bar graph updates 20 times per second\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eData hold, range hold \u0026amp; relative mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto power off\u003c\/strong\u003e after 30 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC61010 CAT III 300V \/ CAT II 600V\u003c\/strong\u003e safety rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Φ25mm clamp\u003c\/strong\u003e – 230g, ideal for crowded panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eMeasuring range\u003c\/th\u003e\n\u003cth\u003eBest accuracy\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACA\u003c\/td\u003e\n\u003ctd\u003e40\/400A\u003c\/td\u003e\n\u003ctd\u003e±(2%±10)\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA\u003c\/td\u003e\n\u003ctd\u003e40\/400A\u003c\/td\u003e\n\u003ctd\u003e±(2.5%±10)\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACV\u003c\/td\u003e\n\u003ctd\u003e400\/600V\u003c\/td\u003e\n\u003ctd\u003e±(1.5%±5)\u003c\/td\u003e\n\u003ctd\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCV\u003c\/td\u003e\n\u003ctd\u003e400\/600V\u003c\/td\u003e\n\u003ctd\u003e±(1%±2)\u003c\/td\u003e\n\u003ctd\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400Ω\u003c\/td\u003e\n\u003ctd\u003e±(1%±2)\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eBuzzer sounds at less than approx. 40Ω Open voltage: approx. 1.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e2 times\/sec., 20 times\/sec. for bar graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e50～500Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp diameter\/Conductor size\u003c\/td\u003e\n\u003ctd\u003eΦ25mm\/10×34mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLR03×2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eApprox. 50 hrs.（Alkaline battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\/Mass\u003c\/td\u003e\n\u003ctd\u003eH193×W50×D28mm\/Approx. 230g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eIEC61010 CAT.Ⅲ300V CAT.Ⅱ600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SANWA","offers":[{"title":"Default Title","offer_id":42978462564564,"sku":"DCM400AD","price":980.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/20220630035449fb1d958eb03ece835925fc1a757890df.png?v=1769148636"},{"product_id":"kyoritsu-2000a-digital-multimeter-600v","title":"KYORITSU 2000A Digital Multimeter with AC\/DC Clamp Sensor ≤600V | KEW 2000A","description":"\u003ch2\u003eKYORITSU 2000A (KEW MATE) Digital Multimeter with AC\/DC Clamp Sensor 60A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2000A\u003c\/strong\u003e combines a 600V digital multimeter with a built-in open AC\/DC clamp sensor, so you can read AC and DC current up to 60A without breaking the circuit. Its slim open jaw (Ø6mm) slips around single conductors in crowded control panels, while the pocket-size body, test probe holster and test lead cap make it a practical everyday tool for electricians and maintenance technicians.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures both AC and DC currents up to 60A with the open clamp sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Cable Protection:\u003c\/strong\u003e Increased cable strength and robust protection ensure durability and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Portable:\u003c\/strong\u003e Pocket-size design makes it easy to carry and store without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Probe Holster:\u003c\/strong\u003e Test probe can be securely fixed to the holster for convenience and safe storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e Equipped with a test lead cap to protect against short circuit accidents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Clamp Jaws:\u003c\/strong\u003e The open jaws are slim, making them perfect for clamping wires even in tight spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e340.0mV \/ 3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (50 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e60.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e340.0Ω \/ 3.400kΩ \/ 34.00kΩ \/ 340.0kΩ \/ 3.400MΩ \/ 34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (0 - 340kΩ); ±5%rdg ±5dgt (3.4MΩ); ±15%rdg ±5dgt (34MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 30 ±10Ω\u003c\/td\u003e\n\u003ctd\u003eWorks only on 340Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eAC A: 3.4Hz - 10kHz; AC V: 3.4Hz - 300kHz\u003c\/td\u003e\n\u003ctd\u003e±0.1%rdg ±1dgt (Current \u0026gt; 15A, Voltage \u0026gt; 30V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ6mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V \/ CAT II 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm × 87 mm × 24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 210g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eSoft carrying case (9107)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu KEW MATE 2000A \/ 2001A \/ 2012RA comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e2000A (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2001a-digital-multimeter\"\u003e2001A\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2012ra-digital-multimeter\"\u003e2012RA\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp sensor AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e60.0A\u003c\/td\u003e\n\u003ctd\u003e100.0A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 120.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ6mm\u003c\/td\u003e\n\u003ctd\u003eØ10mm\u003c\/td\u003e\n\u003ctd\u003eØ12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (max.)\u003c\/td\u003e\n\u003ctd\u003e34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e60.00MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; diode\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 210g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eSmall wires and control panels\u003c\/td\u003e\n\u003ctd\u003eGeneral electrical work up to 100A\u003c\/td\u003e\n\u003ctd\u003eWider current range plus capacitor and diode checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/MUSXQhAcfEI\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42978555101396,"sku":"KE 2000A","price":833.2,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2000A.jpg?v=1794535589"},{"product_id":"kyoritsu-2431-leakage-clamp-meter","title":"KYORITSU 2431 Leakage Clamp Meter | KEW 2431","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2431 Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"727\" data-end=\"779\"\u003e\u003cstrong data-start=\"730\" data-end=\"779\"\u003eOverview of KYORITSU 2431 Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"780\" data-end=\"1287\"\u003eThe \u003cstrong data-start=\"784\" data-end=\"821\"\u003eKYORITSU 2431 Leakage Clamp Meter\u003c\/strong\u003e is a high-performance instrument designed for accurate leakage current measurement in residential, commercial, and industrial electrical systems. The KEW 2431 ensures safe, reliable, and stable readings with its clear digital display and user-friendly design. Its compact size and professional-grade performance make the KYORITSU 2431 Leakage Clamp Meter an essential tool for electricians, maintenance engineers, and technicians performing daily field diagnostics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Eliminates harmonic effects for precise measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power-Off Function:\u003c\/strong\u003e Enhances battery efficiency by turning off the device when idle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotary Switch:\u003c\/strong\u003e Enables effortless power-on and range selection with one hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and easy to carry, suitable for on-site inspections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.01mA for detecting small leakage currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 200mA \/ 200A\u003c\/td\u003e\n\u003ctd\u003e±3%rdg ±5dgt (20\/200mA\/100A); ±5%rdg ±5dgt (200A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 200mA \/ 200A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±4dgt [50\/60Hz] (20\/200mA\/0 - 100A); ±5%rdg ±6dgt [40 - 400Hz] (20\/200mA\/0 - 100A); ±5%rdg ±4dgt [50\/60Hz] (100.1 - 200A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø24mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003eφ15mm 100A\u003c\/td\u003e\n\u003ctd\u003e10mA AC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × LR44 (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e149 mm × 60 mm × 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9090), 2 × LR44 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982649823444,"sku":"KE 2431","price":2379.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/e72912100abb3e0c25c100d0429825c4_f1b0faaa-f582-4f35-b5eb-584e77c91fb4.jpg?v=1769185138"},{"product_id":"kyoritsu-kt200-ac-digital-clamp-meter","title":"KYORITSU KT200 AC Digital Clamp Meter | KEWTECH KT200","description":"\u003ch1 class=\"goods_name\"\u003eKT 200 AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"786\" data-end=\"842\"\u003e\u003cstrong data-start=\"789\" data-end=\"842\"\u003eOverview of KYORITSU KT200 AC Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"843\" data-end=\"1400\"\u003eThe \u003cstrong data-start=\"847\" data-end=\"888\"\u003eKYORITSU KT200 AC Digital Clamp Meter\u003c\/strong\u003e is a compact and reliable current measurement tool designed for electrical professionals who require accurate readings and dependable performance. Engineered for residential, commercial, and industrial environments, the KEWTECH KT 200 provides clear digital indication and stable AC current measurement. With its lightweight form factor and robust construction, the KYORITSU KT200 AC Digital Clamp Meter ensures ease of use and long-term reliability for electricians, service technicians, and maintenance teams.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Handy Design:\u003c\/strong\u003e Lightweight and portable for easy operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A AC Clamp Meter:\u003c\/strong\u003e Handles medium-range AC current measurements with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive DMM Function:\u003c\/strong\u003e Measures AC voltage, DC voltage, resistance, and includes a continuity buzzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V \/ CAT II 600V for secure operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable and Efficient:\u003c\/strong\u003e Provides up to 200 hours of continuous measuring time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±6dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e400Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ30mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V (ACA) \/ CAT II 600V, Pollution Degree 2; IEC 61010-2-032; IEC 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 200 hours (auto power save after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e184 mm × 44 mm × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 190g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9105)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982685081812,"sku":"KE KT200","price":461.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/7ad7f48343efc80dce30f0b95155fb69_5d719ca2-e93b-4157-beb0-2425dffebb36.jpg?v=1769185143"},{"product_id":"kyoritsu-2007r-ac-digital-clamp-meter","title":"KYORITSU 2007R AC Digital Clamp Meter True RMS 1000A | KEW 2007R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2007R AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"653\" data-end=\"709\"\u003e\u003cstrong data-start=\"656\" data-end=\"709\"\u003eOverview of KYORITSU 2007R AC Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"710\" data-end=\"1248\"\u003eThe \u003cstrong data-start=\"714\" data-end=\"755\"\u003eKYORITSU 2007R AC Digital Clamp Meter\u003c\/strong\u003e is a compact, durable, and professional measurement tool designed for precise AC current testing in residential, commercial, and industrial environments. With its ergonomic design and high-accuracy sensing technology, the KEW 2007R ensures stable and reliable readings during daily electrical diagnostic tasks. The KYORITSU 2007R AC Digital Clamp Meter is ideal for electricians, service technicians, and maintenance engineers who require consistent and safe current measurement capabilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Safety Jaw:\u003c\/strong\u003e Ensures reliable and safe measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e The over-molded body allows for convenient one-hand operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e True RMS auto-ranging for AC currents up to 1000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear Display:\u003c\/strong\u003e Large, easy-to-read display with 0.1A resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Battery Life:\u003c\/strong\u003e Features long-lasting power for extended use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Complies with IEC 61010-1 CAT IV 300V \/ CAT III 600V for safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e600.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt (45 - 65Hz); ±2.0%rdg ±4dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (AC V)\u003c\/td\u003e\n\u003ctd\u003e600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.2%rdg ±3dgt (45 - 65Hz); ±1.5%rdg ±4dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DC V)\u003c\/td\u003e\n\u003ctd\u003e600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.2%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±5dgt (600Ω); ±2.0%rdg ±3dgt (6.000kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eSounds below 90Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2 (EMC), IEC 60529 IP40, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 170 hours (when R03 is used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e204 mm × 81 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, carrying case (9079), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2007R vs 2117R vs 2127R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e2007R (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2117r-ac-clamp-meter\"\u003e2117R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2127r-clamp-meter\"\u003e2127R\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current ranges\u003c\/td\u003e\n\u003ctd\u003e600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (max.)\u003c\/td\u003e\n\u003ctd\u003e6.000kΩ\u003c\/td\u003e\n\u003ctd\u003e600.0kΩ\u003c\/td\u003e\n\u003ctd\u003e40.00MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNCV voltage detection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance, diode, frequency\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak hold (inrush)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eStraightforward AC load checks\u003c\/td\u003e\n\u003ctd\u003eEveryday electrical work with built-in voltage detection\u003c\/td\u003e\n\u003ctd\u003eMotor inrush checks and work in dim switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982704709844,"sku":"KE 2007R","price":845.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/KE2007R.png?v=1769185154"},{"product_id":"kyoritsu-kt203-ac-dc-digital-clamp-mete","title":"KYORITSU KT203 AC\/DC Digital Clamp Meter | KEWTECH KT203","description":"\u003ch1 class=\"goods_name\"\u003eKT 203 AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"287\" data-end=\"362\"\u003eKYORITSU KT203 AC\/DC Digital Clamp Meter | KEWTECH KT 203\u003c\/h2\u003e\n\u003cp data-start=\"363\" data-end=\"687\"\u003eThe \u003cstrong data-start=\"367\" data-end=\"411\"\u003eKYORITSU KT203 AC\/DC Digital Clamp Meter\u003c\/strong\u003e delivers reliable measurement performance for electricians and maintenance professionals who require accurate current testing without contact interruption. The KEWTECH KT 203 is designed for safe, efficient diagnostics in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Lightweight:\u003c\/strong\u003e Designed for easy handling and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures currents up to 400A with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDMM Functions:\u003c\/strong\u003e Supports AC\/DC voltage, resistance, and continuity testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V \/ CAT II 600V for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable and Reliable:\u003c\/strong\u003e Built to handle tough environments with robust performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±8dgt [50\/60Hz] (0 - 40.00A); ±3.5%rdg ±6dgt [50\/60Hz] (15.0 - 299.9A); ±4.0%rdg ±6dgt [50\/60Hz] (300.0 - 400.0A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±8dgt (0 - 40.00A); ±3.5%rdg ±6dgt (15.0 - 299.9A); ±4.0%rdg ±6dgt (300.0 - 400.0A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt [50\/60Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ30mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V (ACA) \/ CAT II 600V Pollution Degree 2; IEC 61010-2-032; IEC 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e187 mm × 68.5 mm × 38.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 200g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9105)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3 data-start=\"1252\" data-end=\"1283\"\u003eWhy Choose KYORITSU KT203\u003c\/h3\u003e\n\u003cp data-start=\"1284\" data-end=\"1505\"\u003eThe KYORITSU KT203 provides a dependable combination of precision, durability, and portability. Its AC\/DC current measurement and built-in DMM functions make it suitable for modern electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42982707593428,"sku":"KE KT203","price":845.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/1af247a8d4b23bde71e1c344258a263e_74d54c14-cc2f-4dba-9d44-14bb581fc9a4.jpg?v=1769185168"},{"product_id":"kyoritsu-2433r-leakage-clamp-meter","title":"KYORITSU 2433R Leakage Clamp Meter | KEW 2433R","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2433R Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"844\" data-end=\"895\"\u003e\u003cstrong data-start=\"849\" data-end=\"895\"\u003eKYORITSU 2433R Leakage Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"897\" data-end=\"1502\"\u003eThe \u003cstrong data-start=\"901\" data-end=\"947\"\u003eKYORITSU 2433R Leakage Digital Clamp Meter\u003c\/strong\u003e is a professional instrument designed for accurate measurement of leakage currents in electrical circuits. The \u003cstrong data-start=\"1059\" data-end=\"1072\"\u003eKEW 2433R\u003c\/strong\u003e ensures reliable readings for electricians, technicians, and maintenance personnel in industrial, commercial, and residential settings. Its ergonomic and compact design allows safe and easy handling in the field. With a clear digital display and simple operation, the KYORITSU 2433R Leakage Clamp Meter delivers fast and dependable measurements for troubleshooting, preventive maintenance, and verification of electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Eliminates harmonic effects for accurate and reliable measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Measurement Ranges:\u003c\/strong\u003e 40mA, 400mA, and 400A for diverse applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.01mA enables detection of very small leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates effectively between 20Hz and 1kHz (40Hz to 1kHz for 400A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and ergonomic, ideal for fieldwork and on-site inspections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V standards for safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (40\/400mA); ±1%rdg ±5dgt (0 - 300A); ±2%rdg (300.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±10dgt [20Hz - 1kHz] (40\/400mA); ±2.5%rdg ±10dgt [40Hz - 1kHz] (0 - 300A); ±5%rdg [40Hz - 1kHz] (300.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC (Line\/Neutral); 300V AC\/DC (Earth)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø40mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eApprox. 10mA AC near a 15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz - 1kHz (40Hz - 1kHz for 400A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm × 81 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9052), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42983343554772,"sku":"KE 2433R","price":3186.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/00836a2e8c9bc665ff7b2a3c9e62c184_429782d5-f6d1-4b25-93a8-f63920982d0f.jpg?v=1769185175"},{"product_id":"kyoritsu-2012ra-digital-multimeter","title":"KYORITSU 2012RA Digital Multimeter with AC\/DC Clamp Sensor ≤600V | KEW 2012RA","description":"\u003ch2\u003eKYORITSU 2012RA (KEW MATE) Digital Multimeter with AC\/DC Clamp Sensor 120A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2012RA\u003c\/strong\u003e is a 600V digital multimeter with a built-in open AC\/DC clamp sensor that reads AC and DC current up to 120A without breaking the circuit. It adds capacitance and diode test to the usual voltage, resistance, continuity and frequency functions, and its slim open jaw takes conductors up to Ø12mm in cramped panels.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Measures up to 120A for both AC and DC currents with the open clamp sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Cable Protection:\u003c\/strong\u003e Improved cable strength and protection ensure durability during use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Portable:\u003c\/strong\u003e Small, pocket-sized design for easy portability and convenient storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Probe Holster:\u003c\/strong\u003e Test probe can be securely fixed to the holster for safe and convenient handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e Includes a test lead cap to prevent short circuit accidents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlim Clamp Jaws:\u003c\/strong\u003e The open jaws are designed to fit into tight spaces, making it easy to clamp wires in cramped environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600.0mV \/ 6.000V \/ 60.00V \/ 600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6.000V \/ 60.00V \/ 600.0V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (45 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 120.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±8dgt (60A); ±2.0%rdg ±5dgt (120A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 120.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (45 - 65Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ \/ 60.00kΩ \/ 600.0kΩ \/ 6.000MΩ \/ 60.00MΩ\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±5dgt (600Ω - 600kΩ); ±2.0%rdg ±5dgt (6MΩ); ±3.0%rdg ±5dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 35 ±25Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e2.000V\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±5dgt (Open-loop voltage: approx. 2.7V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance (F)\u003c\/td\u003e\n\u003ctd\u003e400.0nF \/ 4.000µF \/ 40.00µF\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±10dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eAC A: 99.99Hz \/ 400Hz; AC V: 99.99Hz \/ 999.9Hz \/ 9.999kHz \/ 99.99kHz \/ 300.0kHz\u003c\/td\u003e\n\u003ctd\u003e±0.2%rdg ±2dgt (100Hz); ±0.1%rdg ±1dgt (1000Hz \/ 10kHz \/ 300kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ12mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V, CAT II 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm × 92 mm × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads, 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eSoft carrying case (9107)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu KEW MATE 2000A \/ 2001A \/ 2012RA comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2000a-digital-multimeter-600v\"\u003e2000A\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2001a-digital-multimeter\"\u003e2001A\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2012RA (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp sensor AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e60.0A\u003c\/td\u003e\n\u003ctd\u003e100.0A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 120.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ6mm\u003c\/td\u003e\n\u003ctd\u003eØ10mm\u003c\/td\u003e\n\u003ctd\u003eØ12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (max.)\u003c\/td\u003e\n\u003ctd\u003e34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e60.00MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; diode\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 210g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eSmall wires and control panels\u003c\/td\u003e\n\u003ctd\u003eGeneral electrical work up to 100A\u003c\/td\u003e\n\u003ctd\u003eWider current range plus capacitor and diode checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/a8DQVwbSriA\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/mZdYkkV38OM\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/MUSXQhAcfEI\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/kewmate_img02_en.jpg?v=1733479327\" alt=\"Kyoritsu KEW MATE clamp multimeter series\"\u003e\u003c\/p\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":42983368261844,"sku":"KE 2012RA","price":1072.2,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2012RA.jpg?v=1794535650"},{"product_id":"fluke-303-compact-clamp-meter","title":"Fluke 303 Compact AC Clamp Meter 600A","description":"\u003cp\u003eThe Fluke 303 is a compact AC clamp meter for everyday current checks to 600A, with 600V AC\/DC voltage, resistance and continuity. A 30mm jaw, backlit display and CAT III 600V \/ CAT IV 300V rating make it a practical, budget-friendly tester for electricians and maintenance technicians.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current measurement to 600A\u003c\/li\u003e\n\u003cli\u003eAC and DC voltage to 600V\u003c\/li\u003e\n\u003cli\u003eResistance to 4000Ω and continuity beeper (≤70Ω)\u003c\/li\u003e\n\u003cli\u003e30mm jaw for cables up to 30mm diameter\u003c\/li\u003e\n\u003cli\u003eBacklit display and data hold; screen refresh more than 2 times per second\u003c\/li\u003e\n\u003cli\u003eRated CAT III 600V and CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e600.0A; ±1.8% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e400V \/ 600V; ±1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e400V \/ 600V; ±1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e4000Ω; ±1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤70Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw size\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBacklit, refresh \u0026gt;2 times per second, data hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2 x 1.5V AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e208 x 58.5 x 28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCAT III 600V, CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 303 Clamp Meter\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eFluke TL75 test leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e2 x AA batteries (installed)\u003c\/li\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLoad current checks on distribution boards, motors and air-conditioning units\u003c\/li\u003e\n\u003cli\u003eVoltage and continuity checks during installation and maintenance\u003c\/li\u003e\n\u003cli\u003eFacility and building maintenance toolkits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 300 Series Clamp Meter comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301b-clamp-meter\"\u003eFluke 301B\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301c-clamp-meter\"\u003eFluke 301C\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301d-clamp-meter\"\u003eFluke 301D\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301e-clamp-meter\"\u003eFluke 301E\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-302-digital-clamp-meter\"\u003eFluke 302+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 303 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-305-true-rms-clamp-meter\"\u003eFluke 305\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance \u0026amp; frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AA\u003c\/td\u003e\n\u003ctd\u003e2 x AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic AC checks to 600A\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS AC to 1000A\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 600A (solar, battery, automotive)\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 1000A\u003c\/td\u003e\n\u003ctd\u003eSimple 400A AC checks\u003c\/td\u003e\n\u003ctd\u003e600A AC on CAT III 600V circuits\u003c\/td\u003e\n\u003ctd\u003eHigh-current AC to 999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000058347732,"sku":"FK 303","price":824.8,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke-303.jpg?v=1794534984"},{"product_id":"fluke-305-true-rms-clamp-meter","title":"Fluke 305 True-RMS AC Clamp Meter 1000A","description":"\u003cp\u003eThe Fluke 305 is a compact AC clamp meter for high-current work, measuring AC current to 999.9A through a 30mm jaw, with 600V AC\/DC voltage, resistance and continuity. Its backlit display, data hold and CAT III 600V \/ CAT IV 300V rating suit electricians and maintenance teams working on large feeders and motors.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current measurement to 999.9A\u003c\/li\u003e\n\u003cli\u003eAC and DC voltage to 600V\u003c\/li\u003e\n\u003cli\u003eResistance to 4000Ω and continuity beeper (≤70Ω)\u003c\/li\u003e\n\u003cli\u003e30mm jaw opening\u003c\/li\u003e\n\u003cli\u003eBacklit display and data hold; refresh more than 2 times per second\u003c\/li\u003e\n\u003cli\u003eRated CAT III 600V and CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e999.9A; ±2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e400V \/ 600V; ±1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e400V \/ 600V; ±1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e4000Ω; ±1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤70Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw size\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2 x 1.5V AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e208 x 58.5 x 28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCAT III 600V, CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 305 Clamp Meter\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eFluke TL75 test leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e2 x AA batteries\u003c\/li\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eFluke TL75 Hard Point Test Lead Set\u003c\/a\u003e (replacement)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMain feeder, busbar and large motor current checks to 999.9A\u003c\/li\u003e\n\u003cli\u003eDistribution board voltage and continuity checks\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 300 Series Clamp Meter comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301b-clamp-meter\"\u003eFluke 301B\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301c-clamp-meter\"\u003eFluke 301C\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301d-clamp-meter\"\u003eFluke 301D\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301e-clamp-meter\"\u003eFluke 301E\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-302-digital-clamp-meter\"\u003eFluke 302+\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-303-compact-clamp-meter\"\u003eFluke 303\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 305 (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance \u0026amp; frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AA\u003c\/td\u003e\n\u003ctd\u003e2 x AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic AC checks to 600A\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS AC to 1000A\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 600A (solar, battery, automotive)\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 1000A\u003c\/td\u003e\n\u003ctd\u003eSimple 400A AC checks\u003c\/td\u003e\n\u003ctd\u003e600A AC on CAT III 600V circuits\u003c\/td\u003e\n\u003ctd\u003eHigh-current AC to 999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000061034708,"sku":"FK 305","price":842.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke-305.jpg?v=1794535309"},{"product_id":"fluke-317-true-rms-clamp-meter","title":"Fluke 317 True-RMS AC\/DC Clamp Meter 600A","description":"\u003cp\u003eThe Fluke 317 is a True-RMS AC\/DC clamp meter that measures up to 600A AC and DC current through a 37mm jaw, plus 600V AC\/DC voltage, resistance and continuity. A 40A low range gives fine resolution on small loads, and the large backlit display makes readings easy in dim panels.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC current and voltage for accurate readings on non-linear loads\u003c\/li\u003e\n\u003cli\u003eAC and DC current to 600A, with a 40.00A range for 0.01A resolution on small loads\u003c\/li\u003e\n\u003cli\u003e600V AC\/DC voltage, resistance to 4000Ω and continuity beeper (≤30Ω)\u003c\/li\u003e\n\u003cli\u003e37mm jaw opening\u003c\/li\u003e\n\u003cli\u003eLarge backlit display and low-battery indicator\u003c\/li\u003e\n\u003cli\u003eCAT III 600V, IP40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 600.0A; ±(1.6% + 6) at 40A (50–60Hz), ±(1.5% + 5) at 600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 600.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage (20–500Hz)\u003c\/td\u003e\n\u003ctd\u003e600.0V; ±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e600.0V; ±(1% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω; ±(1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤30Ω with beeper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5V AAA (IEC LR03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e234 x 75 x 34.8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e384g (with batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCAT III 600V\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 61010-1 and IEC 61010-2-032; CE\u003c\/li\u003e\n\u003cli\u003eIP40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 317 Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003e3 x AAA batteries (installed)\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke AC285 SureGrip Alligator Clips\u003c\/li\u003e\n\u003cli\u003eFluke TL223 SureGrip Electrical Test Lead Set\u003c\/li\u003e\n\u003cli\u003eFluke L206 Deluxe LED Hat Light\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolar PV, battery and DC drive current measurement\u003c\/li\u003e\n\u003cli\u003eMotor, HVAC and distribution board load checks\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial electrical maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 310 \u0026amp; 320 Series True-RMS Clamp Meter comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eFluke 317 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-319-clamp-meter\"\u003eFluke 319\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-323-true-rms-clamp-meter\"\u003eFluke 323\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-324-plus-true-clamp-meter\"\u003eFluke 324\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-325-true-rms-clamp-meter\"\u003eFluke 325\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5–500Hz\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5–500Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance \u0026amp; temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw \/ max conductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 600A\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 1000A with inrush for motors\u003c\/td\u003e\n\u003ctd\u003eSimple True-RMS AC checks\u003c\/td\u003e\n\u003ctd\u003eHVAC work needing temperature \u0026amp; capacitance\u003c\/td\u003e\n\u003ctd\u003eSolar, battery \u0026amp; drive work needing DC and frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000062542036,"sku":"FK 317","price":1280.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke-317.jpg?v=1794535046"},{"product_id":"fluke-323-true-rms-clamp-meter","title":"Fluke 323 True-RMS AC Clamp Meter 400A","description":"\u003cp\u003eThe Fluke 323 is a compact True-RMS clamp meter for accurate AC current measurement to 400A on non-linear loads, with 600V AC\/DC voltage, resistance and continuity in a slim, easy-to-handle body. It is a dependable everyday tester for electricians and maintenance technicians working on commercial and residential installations.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC current to 400A for accurate readings on drives, LED lighting and other non-linear loads\u003c\/li\u003e\n\u003cli\u003e600V AC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eResistance to 4000Ω and continuity detection with beeper (≤70Ω)\u003c\/li\u003e\n\u003cli\u003eAccepts conductors up to 30mm (600 MCM)\u003c\/li\u003e\n\u003cli\u003eData hold to freeze the reading\u003c\/li\u003e\n\u003cli\u003eRated CAT III 600V and CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e400.0A; ±(2% + 5) at 45–65Hz, ±(2.5% + 5) at 65–400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e600.0V; ±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e600.0V; ±(1.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω; ±(1.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤70Ω with beeper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax conductor size\u003c\/td\u003e\n\u003ctd\u003e30mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCAT III 600V, CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 323 True-RMS Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTest leads (1 pair)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl175-twistguard%E2%84%A2-test-leads-set\"\u003eFluke TL175 TwistGuard Test Lead Set\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eFluke TL223 SureGrip Electrical Test Lead Set\u003c\/li\u003e\n\u003cli\u003eFluke C43 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003eFluke CAMO-37 Camouflage Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLoad current checks on distribution boards, motors and HVAC units\u003c\/li\u003e\n\u003cli\u003eTroubleshooting circuits with VFDs, LED drivers and electronic loads\u003c\/li\u003e\n\u003cli\u003eVoltage and continuity checks during installation and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 310 \u0026amp; 320 Series True-RMS Clamp Meter comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-317-true-rms-clamp-meter\"\u003eFluke 317\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-319-clamp-meter\"\u003eFluke 319\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 323 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-324-plus-true-clamp-meter\"\u003eFluke 324\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-325-true-rms-clamp-meter\"\u003eFluke 325\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5–500Hz\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5–500Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance \u0026amp; temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw \/ max conductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 600A\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 1000A with inrush for motors\u003c\/td\u003e\n\u003ctd\u003eSimple True-RMS AC checks\u003c\/td\u003e\n\u003ctd\u003eHVAC work needing temperature \u0026amp; capacitance\u003c\/td\u003e\n\u003ctd\u003eSolar, battery \u0026amp; drive work needing DC and frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000065622228,"sku":"FK 323","price":1359.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke-323.jpg?v=1794534579"},{"product_id":"fluke-324-plus-true-clamp-meter","title":"Fluke 324 True-RMS Clamp Meter, 400A AC Current with Temperature \u0026 Capacitance","description":"\u003cstyle\u003e\n\/* Scoped styles for the product description *\/\n.product-description {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n}\n.product-description .highlight {\n    color: #6633ff;\n    font-weight: bold;\n}\n.product-description .offer {\n    color: #e74c3c;\n    font-weight: bold;\n}\n.product-description table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n}\n.product-description table, \n.product-description th, \n.product-description td {\n    border: 1px solid #ddd;\n}\n.product-description th, \n.product-description td {\n    padding: 8px;\n    text-align: left;\n}\n.product-description th {\n    background-color: #f4f4f4;\n}\n.product-description .section-title {\n    color: #333;\n    margin-top: 20px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 324 True-RMS Clamp Meter with Temperature \u0026amp; Capacitance\u003c\/h1\u003e\n\u003ch2 data-end=\"658\" data-start=\"601\"\u003e\u003cstrong data-end=\"656\" data-start=\"605\"\u003eOverview of FLUKE 324 Plus True-RMS Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1238\" data-start=\"659\"\u003eThe \u003cstrong data-end=\"702\" data-start=\"663\"\u003eFLUKE 324 Plus True-RMS Clamp Meter\u003c\/strong\u003e is a professional-grade electrical testing tool designed for electricians, maintenance technicians, and industrial engineers. It offers precise AC current and AC\/DC voltage measurements with True-RMS accuracy, ensuring dependable readings on linear and non-linear loads. The \u003cstrong data-end=\"1014\" data-start=\"975\"\u003eFLUKE 324 Plus True-RMS Clamp Meter\u003c\/strong\u003e also supports resistance and continuity testing, making it a versatile solution for troubleshooting, preventive maintenance, and installation verification in commercial, industrial, and residential applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Fluke lists the 324 as discontinued.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS measurements for precise results on non-linear signals.\u003c\/li\u003e\n\u003cli\u003eMeasures AC current up to 400 A and AC\/DC voltage up to 600 V.\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 4 kΩ with continuity detection ≤30 Ω.\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -10°C to 400°C (14°F to 752°F).\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance up to 1000 μF.\u003c\/li\u003e\n\u003cli\u003eBacklit display for easy visibility in dim environments.\u003c\/li\u003e\n\u003cli\u003eHold function to capture a reading on the display.\u003c\/li\u003e\n\u003cli\u003eSafety rated to CAT III 600 V and CAT IV 300 V.\u003c\/li\u003e\n\u003cli\u003eIncludes TL75 Test Leads, Type K Thermocouple, two AAA batteries, and a soft carrying case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAccuracy Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 digits) (45 Hz to 400 Hz)\u003cbr\u003eNote: Add 2% for position sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω \/ 4000 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e0 to 100.0 μF \/ 100.0 μF to 1000 μF\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤30 Ω\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 400°C (14°F to 752°F)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing; ≤90% RH at 10°C–30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V, CAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e208 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFluke 323 vs 324 vs 325 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-323-true-rms-clamp-meter\"\u003eFluke 323\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 324 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-325-true-rms-clamp-meter\"\u003eFluke 325\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 µF\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature (contact)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 400 °C\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 400 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Ω\u003c\/td\u003e\n\u003ctd\u003e4000 Ω\u003c\/td\u003e\n\u003ctd\u003e40 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay backlight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC current and voltage checks on a budget\u003c\/td\u003e\n\u003ctd\u003eAdds temperature and capacitance for HVAC work\u003c\/td\u003e\n\u003ctd\u003eAdds DC current and frequency for solar, battery and drive work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000067326164,"sku":"FK 324","price":2565.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/e4e9455633da767446f64ed0d58b7e02.jpg?v=1769186089"},{"product_id":"fluke-325-true-rms-clamp-meter","title":"Fluke 325 True-RMS AC\/DC Clamp Meter 400A","description":"\u003ch2\u003eFluke 325 True RMS Clamp Meter\u003c\/h2\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of Fluke 325 True-RMS Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 325 True-RMS Clamp Meter\u003c\/strong\u003e is a professional electrical testing instrument designed for electricians, industrial technicians, and maintenance engineers. It delivers precise AC\/DC current measurements, with True-RMS accuracy on AC current and voltage, ensuring reliable readings on both linear and non-linear loads. The \u003cstrong\u003eFluke 325 True-RMS Clamp Meter\u003c\/strong\u003e also supports voltage, resistance, and continuity testing, making it a versatile tool for troubleshooting, installation verification, and preventive maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC (True-RMS) and DC current measurements up to 400A.\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurements up to 600 V.\u003c\/li\u003e\n\u003cli\u003eMeasures resistance up to 40 kΩ with continuity detection ≤30 Ω.\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance from 0 to 1000 μF.\u003c\/li\u003e\n\u003cli\u003eMeasures frequency from 5 Hz to 500 Hz.\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -10 °C to 400 °C (14 °F to 752 °F) using an included K-type thermocouple.\u003c\/li\u003e\n\u003cli\u003eMin\/Max function for recording significant values, plus data hold.\u003c\/li\u003e\n\u003cli\u003eBacklit display for easy visibility in low-light environments.\u003c\/li\u003e\n\u003cli\u003eSafety rated to CAT III 600 V, CAT IV 300 V.\u003c\/li\u003e\n\u003cli\u003eIncludes a soft carrying case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAccuracy Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits) (45 Hz to 65 Hz)\u003cbr\u003e±(2.5% + 5 digits) (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω \/ 4000 Ω \/ 40.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e0 to 100.0 μF \/ 100.0 μF to 1000 μF\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Temperature\u003c\/td\u003e\n\u003ctd\u003e-10.0°C to 400.0°C (14.0°F to 752.0°F)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing; ≤90% RH at 10°C–30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V, CAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e207 × 75 × 34mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e283g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤30Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2 × AAA (installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eFluke 325 clamp meter, \u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eTL75 test leads\u003c\/a\u003e, Type K thermocouple, 2 × AAA batteries, soft case\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFluke 323 vs 324 vs 325 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-323-true-rms-clamp-meter\"\u003eFluke 323\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-324-plus-true-clamp-meter\"\u003eFluke 324\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 325 (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 µF\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature (contact)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 400 °C\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 400 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Ω\u003c\/td\u003e\n\u003ctd\u003e4000 Ω\u003c\/td\u003e\n\u003ctd\u003e40 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay backlight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC current and voltage checks on a budget\u003c\/td\u003e\n\u003ctd\u003eAdds temperature and capacitance for HVAC work\u003c\/td\u003e\n\u003ctd\u003eAdds DC current and frequency for solar, battery and drive work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl175-twistguard%E2%84%A2-test-leads-set\"\u003eFluke TL175 TwistGuard test lead set\u003c\/a\u003e – extendable insulated tips for safe probing in CAT III\/CAT IV areas\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eFluke TL224 SureGrip silicone test lead set\u003c\/a\u003e – flexible silicone-insulated leads that stay supple in heat and cold\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-c25-large-soft-case-for-digital-multimeter\"\u003eFluke C25 large soft carrying case\u003c\/a\u003e – padded case for the meter, leads and small accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000072863956,"sku":"FK 325","price":2950.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke-325.jpg?v=1794535659"},{"product_id":"fluke-375-true-rms-clamp-meter","title":"Fluke 375 True-RMS AC\/DC Clamp Meter 600A 60kΩ","description":"\u003cstyle\u003e\n\/* Scoped styles for the product description *\/\n.product-description {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n}\n.product-description .highlight {\n    color: #6633ff;\n    font-weight: bold;\n}\n.product-description .offer {\n    color: #e74c3c;\n    font-weight: bold;\n}\n.product-description table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n}\n.product-description table, \n.product-description th, \n.product-description td {\n    border: 1px solid #ddd;\n}\n.product-description th, \n.product-description td {\n    padding: 8px;\n    text-align: left;\n}\n.product-description th {\n    background-color: #f4f4f4;\n}\n.product-description .section-title {\n    color: #333;\n    margin-top: 20px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 375 True RMS AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003ch2 data-end=\"646\" data-start=\"594\"\u003e\u003cstrong data-end=\"644\" data-start=\"598\"\u003eOverview of FLUKE 375 True-RMS Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1175\" data-start=\"647\"\u003eThe \u003cstrong data-end=\"685\" data-start=\"651\"\u003eFLUKE 375 True-RMS Clamp Meter\u003c\/strong\u003e is a professional-grade electrical testing tool designed for electricians, maintenance engineers, and industrial technicians. It provides accurate AC\/DC current measurements up to 600A and resistance testing up to 60kΩ. With True-RMS functionality, the \u003cstrong data-end=\"973\" data-start=\"939\"\u003eFLUKE 375 True-RMS Clamp Meter\u003c\/strong\u003e ensures precise readings on non-linear loads and is suitable for troubleshooting, preventive maintenance, and verifying electrical installations in residential, commercial, and industrial environments.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS AC and DC current measurements up to 600 A (expandable to 2500 A AC with iFlex®).\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurements up to 1000 V.\u003c\/li\u003e\n\u003cli\u003eMeasures frequency from 5 Hz to 500 Hz and resistance up to 60 kΩ with continuity detection.\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance up to 1000 µF.\u003c\/li\u003e\n\u003cli\u003eIncludes Min\/Max\/Avg and inrush recording for capturing variations.\u003c\/li\u003e\n\u003cli\u003eCompatible with optional iFlex® flexible current probe for expanded measurement capability.\u003c\/li\u003e\n\u003cli\u003eSafety rated to CAT III 1000 V, CAT IV 600 V.\u003c\/li\u003e\n\u003cli\u003eCompact design with a large backlit display for ease of use.\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries and includes a soft carrying case.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAccuracy Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current via Jaw\u003c\/td\u003e\n\u003ctd\u003e600.0 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits) (10-100 Hz)\u003cbr\u003e±(2.5% + 5 digits) (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e600.0 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e1000.0 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 digits) (20-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e1000.0 V\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000 µF\u003c\/td\u003e\n\u003ctd\u003e±(1% + 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency via Jaw\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz - 500.0 Hz\u003c\/td\u003e\n\u003ctd\u003e±(0.5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing; ≤90% RH at 10°C–30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e246 x 83 x 43 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e388 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e2 AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFluke 375 vs 376 vs 378 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eFluke 375 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-376-true-rms-clamp-meter\"\u003eFluke 376\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-378-true-rms-clamp-meter\"\u003eFluke 378\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via iFlex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2500 A (optional iFlex probe)\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eiFlex i2500-18 probe in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldSense non-contact voltage and PQ indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest leads in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL224 with TP175 probes and AC285 clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 600 A in a 1000 V meter\u003c\/td\u003e\n\u003ctd\u003eLarger conductors and awkward busbars with iFlex\u003c\/td\u003e\n\u003ctd\u003eVoltage and current without test leads, plus power quality hints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-i2500-18-flexible-current-probe\"\u003eFluke i2500-18 iFlex flexible current probe\u003c\/a\u003e – wraps around large conductors and busbars for AC current up to 2500 A\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eFluke TL224 SureGrip silicone test lead set\u003c\/a\u003e – flexible silicone-insulated leads that stay supple in heat and cold\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tpak-magnetic-hanger\"\u003eFluke TPAK magnetic meter hanger\u003c\/a\u003e – hangs the meter on a panel door or steel surface for hands-free readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000074207444,"sku":"FK 375","price":4536.1,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/b5768d88d7258673cc9fb42528151d4f.jpg?v=1769186129"},{"product_id":"fluke-376-true-rms-clamp-meter","title":"FLUKE 376 True-RMS AC\/DC Clamp Meter With iFlex 1000A","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eFluke 376 True RMS AC\/DC Clamp Meter with iFlex®\u003c\/h2\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 376 True-RMS Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 376 True-RMS Clamp Meter with iFlex\u003c\/strong\u003e is a high-performance electrical testing tool designed for electricians and industrial maintenance professionals. It provides precise AC\/DC current measurements up to 1000A and True-RMS voltage readings for accurate diagnostics. The included \u003cstrong\u003eiFlex® flexible current probe\u003c\/strong\u003e allows users to measure in confined or hard-to-reach areas, making the \u003cstrong\u003eFLUKE 376 True-RMS Clamp Meter\u003c\/strong\u003e ideal for troubleshooting, preventive maintenance, and installation verification in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003cp\u003eThis listing is the standard Fluke 376. The Fluke 376 FC is a separate model that adds Fluke Connect wireless connectivity.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC voltage up to 1000V and AC\/DC current up to 999.9A via jaw.\u003c\/li\u003e\n\u003cli\u003eExtended range up to 2500A AC with the iFlex® flexible current probe.\u003c\/li\u003e\n\u003cli\u003eTrue RMS voltage and current measurements for accurate readings on non-linear loads.\u003c\/li\u003e\n\u003cli\u003eSafety conformance: CAT IV 600V, CAT III 1000V.\u003c\/li\u003e\n\u003cli\u003eCompact, ergonomic design for one-handed operation.\u003c\/li\u003e\n\u003cli\u003eFrequency, resistance, capacitance and mV DC measurements, plus inrush current measurement.\u003c\/li\u003e\n\u003cli\u003eBacklit display for improved visibility in low-light conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376 True RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003e2 AA alkaline batteries (installed)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eTL75 test leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eCoated instruction card (quick reference guide)\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eElectrical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current via Jaw\u003c\/td\u003e\n\u003ctd\u003e600.0A \/ 999.9A\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003ctd\u003e±2% ±5 digits (10–100Hz); ±2.5% ±5 digits (100–500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current via iFlex® Probe\u003c\/td\u003e\n\u003ctd\u003e2500A\u003c\/td\u003e\n\u003ctd\u003e0.1A (≤ 999.9A); 1A (≤ 2500A)\u003c\/td\u003e\n\u003ctd\u003e±3% ±5 digits (5–500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e600.0A \/ 999.9A\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003ctd\u003e±2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e600.0V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e0.1V (≤ 600.0V); 1V (≤ 1000V)\u003c\/td\u003e\n\u003ctd\u003e±1.5% ±5 digits (20–500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e600.0V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e0.1V (≤ 600.0V); 1V (≤ 1000V)\u003c\/td\u003e\n\u003ctd\u003e±1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC\u003c\/td\u003e\n\u003ctd\u003e500.0mV\u003c\/td\u003e\n\u003ctd\u003e0.1mV\u003c\/td\u003e\n\u003ctd\u003e±1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (jaw or iFlex®)\u003c\/td\u003e\n\u003ctd\u003e5.0–500.0Hz\u003c\/td\u003e\n\u003ctd\u003e0.1Hz\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60kΩ\u003c\/td\u003e\n\u003ctd\u003e0.1Ω (≤ 600Ω); 1Ω (≤ 6000Ω); 10Ω (≤ 60kΩ)\u003c\/td\u003e\n\u003ctd\u003e±1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000μF\u003c\/td\u003e\n\u003ctd\u003e0.1μF (≤ 100μF); 1μF (≤ 1000μF)\u003c\/td\u003e\n\u003ctd\u003e±1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFLUKE-376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBacklit, 6000-count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eiFlex® Probe\u003c\/td\u003e\n\u003ctd\u003e18-inch; cable diameter 7.5mm; cable length (head to connector) 1.8m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e2 × AA (NEDA 15A, IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e60 hours (typical, without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V, CAT III 1000V; pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61010-1:2001; EN\/IEC 61010-2-032:2002; EN\/IEC 61010-031:2002+A1:2008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing; ≤90% RH (10–30°C), ≤75% RH (30–40°C), ≤45% RH (40–50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating 3,000m; storage 12,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e246 × 83 × 43mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e388g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFluke 375 vs 376 vs 378 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-375-true-rms-clamp-meter\"\u003eFluke 375\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 376 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-378-true-rms-clamp-meter\"\u003eFluke 378\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via iFlex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2500 A (optional iFlex probe)\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eiFlex i2500-18 probe in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldSense non-contact voltage and PQ indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest leads in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL224 with TP175 probes and AC285 clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 600 A in a 1000 V meter\u003c\/td\u003e\n\u003ctd\u003eLarger conductors and awkward busbars with iFlex\u003c\/td\u003e\n\u003ctd\u003eVoltage and current without test leads, plus power quality hints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eFluke TL224 SureGrip silicone test lead set\u003c\/a\u003e – flexible silicone-insulated leads that stay supple in heat and cold\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000076009684,"sku":"FK 376","price":4222.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/a5d558c4d3ce9be369dd26253b86377a.jpg?v=1769186143"},{"product_id":"fluke-378-true-rms-clamp-meter","title":"Fluke 378 True-RMS AC\/DC Clamp Meter With iFlex","description":"\u003cstyle\u003e\n\/* Scoped styles for the product description *\/\n.product-description {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n}\n.product-description .highlight {\n    color: #6633ff;\n    font-weight: bold;\n}\n.product-description .offer {\n    color: #e74c3c;\n    font-weight: bold;\n}\n.product-description table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n}\n.product-description table, \n.product-description th, \n.product-description td {\n    border: 1px solid #ddd;\n}\n.product-description th, \n.product-description td {\n    padding: 8px;\n    text-align: left;\n}\n.product-description th {\n    background-color: #f4f4f4;\n}\n.product-description .section-title {\n    color: #333;\n    margin-top: 20px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 378 Non-Contact Voltage True-RMS AC\/DC Clamp Meter with iFlex\u003c\/h1\u003e\n\u003ch2 data-end=\"665\" data-start=\"613\"\u003e\u003cstrong data-end=\"663\" data-start=\"617\"\u003eOverview of Fluke 378 True-RMS Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1192\" data-start=\"666\"\u003eThe \u003cstrong data-end=\"715\" data-start=\"670\"\u003eFluke 378 True-RMS Clamp Meter with iFlex\u003c\/strong\u003e is a professional-grade electrical testing instrument designed for electricians and maintenance technicians. It provides accurate AC\/DC current and voltage measurements while offering True-RMS accuracy for precise readings in complex electrical systems. The included flexible \u003cstrong data-end=\"1016\" data-start=\"992\"\u003eiFlex® current probe\u003c\/strong\u003e allows measurement in tight spaces or around large conductors, making the \u003cstrong data-end=\"1125\" data-start=\"1091\"\u003eFluke 378 True-RMS Clamp Meter\u003c\/strong\u003e ideal for industrial, commercial, and residential troubleshooting.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense™ technology for non-contact voltage and current measurements.\u003c\/li\u003e\n\u003cli\u003ePower Quality (PQ) indicator to identify power supply or equipment issues.\u003c\/li\u003e\n\u003cli\u003eIncludes iFlex® flexible current probe for measuring AC currents up to 2500 A.\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC voltage and current measurements for non-linear signals.\u003c\/li\u003e\n\u003cli\u003eMeasures DC current, voltage, resistance, capacitance, and frequency.\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V safety rating for enhanced protection.\u003c\/li\u003e\n\u003cli\u003eBright green visual continuity screen for easy identification in noisy environments.\u003c\/li\u003e\n\u003cli\u003eThree-phase voltage and current measurement capability with calculated phase values.\u003c\/li\u003e\n\u003cli\u003eCompact and durable design with an ergonomic grip and backlit dual display.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAccuracy Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current via Jaw\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits) (45-66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current via iFlex®\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e1 A (≤2500 A) \/ 0.1 A (≤999.9 A)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 digits) (5-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (FieldSense)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 digits) (45-66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω - 10 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.1 μF - 1 μF\u003c\/td\u003e\n\u003ctd\u003e±(1% + 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e274 x 86 x 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e463 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFluke 375 vs 376 vs 378 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-375-true-rms-clamp-meter\"\u003eFluke 375\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-376-true-rms-clamp-meter\"\u003eFluke 376\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 378 (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via iFlex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2500 A (optional iFlex probe)\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eiFlex i2500-18 probe in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldSense non-contact voltage and PQ indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest leads in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL224 with TP175 probes and AC285 clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 600 A in a 1000 V meter\u003c\/td\u003e\n\u003ctd\u003eLarger conductors and awkward busbars with iFlex\u003c\/td\u003e\n\u003ctd\u003eVoltage and current without test leads, plus power quality hints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in USA\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000076992724,"sku":"FK 378","price":7659.8,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/cefefabd0932178e605d28a16c576b88.jpg?v=1769186173"},{"product_id":"sanwa-dcl1000-clamp-meter","title":"Sanwa AC Clamp Meter, 1000A, CAT III 600V, with Multimeter Functions – DCL1000","description":"\u003ch1\u003eOverview of SANWA DCL1000 Digital Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe SANWA DCL1000 is a professional-grade digital clamp meter that combines high-current AC measurement (up to 1000 A) with full digital multimeter (DMM) capabilities. Built for demanding electrical and low-voltage power-supply work, it features a large display, data-hold, range hold, relative-value, and a lightweight browse-friendly body of approx. 290 g. Designed to IEC CAT III 600 V safety standard, the DCL1000 is ideal for electricians, maintenance technicians, and industrial users.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures AC current up to \u003cstrong\u003e1000 A\u003c\/strong\u003e via clamp sensor. \u003cspan class=\"\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital multimeter functions: AC\/DC voltage, resistance, continuity buzzer, diode test. \u003cspan class=\"\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight approx. \u003cstrong\u003e290 g\u003c\/strong\u003e and compact form for easier handling. \u003cspan class=\"\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge LCD display, data-hold and range-hold functions. \u003cspan class=\"\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClamp diameter approx. Φ42 mm (suitable conductor size 20×54 mm) for flexible measurement. \u003cspan class=\"\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety compliant: IEC 61010 category CAT III 600 V.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003eSpecification Table\u003cbr\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSANWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDCL1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (Clamp)\u003c\/td\u003e\n\u003ctd\u003e400 A \/ 1000 A (±1.7% + 5) resolution 0.1 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DMM)\u003c\/td\u003e\n\u003ctd\u003e400 mV \/ 4 V \/ 40 V \/ 400 V \/ 600 V (±1.2% +3) resolution 0.1 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e400 mV \/ 4 V \/ 40 V \/ 400 V \/ 600 V (±2.2% +5) resolution 0.1 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400 Ω \/ 4 kΩ \/ 40 kΩ \/ 400 kΩ \/ 4 MΩ \/ 40 MΩ (±1.2% +4) resolution 0.1 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003eBuzzer at approx 0–65 Ω open volt 0.4 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eApprox. 3 times\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Diameter\u003c\/td\u003e\n\u003ctd\u003eΦ 42 mm \/ conductor size 20×54 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Count\u003c\/td\u003e\n\u003ctd\u003e4000 counts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 290 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003eH 238 × W 95 × D 45 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-032 CAT III 600V, IEC 61010-031, IEC 61326-1 EMC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\/Humidity\u003c\/td\u003e\n\u003ctd\u003e5°C-40°C, ≤80%RH; –20°C-60°C storage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e📦 Package Content\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 × SANWA DCL1000 Clamp Meter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × \u003ca href=\"\/ms\/products\/sanwa-tl-23a-electric-instruments-multimeter-test-lead\"\u003eSet of test leads (TL-23a)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Carrying case (C-DCL1000) \u003cspan class=\"\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Instruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e💡 Why Choose SANWA\u003c\/h2\u003e\n\u003cp\u003eSANWA is a respected Japanese brand with decades of experience designing precision measurement instruments. Engineers and technicians worldwide trust SANWA meters for reliability, accuracy, and build-quality. The DCL1000 combines the practicality of a clamp meter with digital multimeter versatility — reducing tool count and boosting efficiency on-site.\u003c\/p\u003e","brand":"SANWA","offers":[{"title":"Default Title","offer_id":43000159600852,"sku":"DCL1000","price":438.2,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/SANWA_DCL1000_01.png?v=1769186578"},{"product_id":"sanwa-dcm60r-ac-clamp-meter-true-rms","title":"Sanwa AC Clamp Meter, 600A, True RMS, Compact – DCM60R","description":"\u003cp\u003eThe \u003cstrong\u003eSanwa DCM60R AC Clamp Meter\u003c\/strong\u003e is a compact True RMS clamp meter for measuring AC current up to 600A, AC voltage up to 600V and resistance. Its slim Φ25mm jaw and light 210g body make it easy to carry for everyday electrical maintenance.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS for accurate readings on non-sine waveforms\u003c\/li\u003e\n\u003cli\u003eAC current up to 600A\u003c\/li\u003e\n\u003cli\u003eAC voltage up to 600V\u003c\/li\u003e\n\u003cli\u003eResistance and continuity buzzer\u003c\/li\u003e\n\u003cli\u003eData hold\u003c\/li\u003e\n\u003cli\u003eCompact Φ25mm jaw, approx. 210g\u003c\/li\u003e\n\u003cli\u003eIEC 61010 CAT III 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDCM60R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e199.9 \/ 600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e199.9 \/ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e199.9Ω, ±(1.9%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003eBuzzer below approx. 100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e50–400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Diameter\u003c\/td\u003e\n\u003ctd\u003eΦ25mm (conductor 10 × 30mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010 CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize \/ Mass\u003c\/td\u003e\n\u003ctd\u003eH187 × W50 × D29mm \/ approx. 210g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"SANWA","offers":[{"title":"Default Title","offer_id":43000161468628,"sku":"DCM60R","price":276.3,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/4e932bfb440800a3c78546a777ce794e_3acee492-b935-4aad-b20e-e25dca5c6048.jpg?v=1769148917"},{"product_id":"kyoritsu-2200r-digital-clamp-meter-with-true-rms-ke2200r-1000a-ac-and-600v-ranging","title":"KYORITSU 2200R AC Digital Clamp Meter True RMS 1000A | KEW 2200R","description":"\u003ch2\u003eKYORITSU 2200R True RMS AC Digital Clamp Meter 1000A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2200R Digital Clamp Meter\u003c\/strong\u003e is a high-accuracy True-RMS instrument for measuring AC current (up to 1000A), AC\/DC voltage, and resistance. It measures AC current only; it does not measure DC current. The \u003cstrong\u003eKEW 2200R\u003c\/strong\u003e allows safe and efficient clamp measurements without disconnecting circuits, making it ideal for electricians, technicians, and maintenance professionals. Its compact, ergonomic design ensures portability, while the durable housing protects the meter during regular field use. With a clear digital display, the KYORITSU 2200R Digital Clamp Meter delivers fast, reliable readings, ensuring accurate electrical testing in workshops, industrial sites, and on-site inspections.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/2200.png?v=1733495870\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Slim and Lightweight:\u003c\/strong\u003e Compact design for easy portability and handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTeardrop-Shaped Jaws:\u003c\/strong\u003e φ33mm jaws for convenient operation in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000A AC Clamp Meter:\u003c\/strong\u003e Measures high AC currents with precision (AC current only).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive DMM Function:\u003c\/strong\u003e Measures AC voltage, DC voltage, resistance, and includes a continuity buzzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuseless Protection:\u003c\/strong\u003e Protects Ω\/Continuity measurements up to 600V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Resolution:\u003c\/strong\u003e Offers a resolution of 0.01A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 300V \/ CAT III 600V and IEC 61010-2-032 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (45 - 65Hz); ±2.0%rdg ±5dgt (40 - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003eNot available (AC current only)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.8%rdg ±7dgt (45 - 65Hz); ±2.3%rdg ±8dgt (65 - 500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0mV \/ 4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt (400mV range excluded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4.000kΩ \/ 40.00kΩ \/ 400.0kΩ \/ 4.000MΩ \/ 40.00MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±4dgt (0 - 400kΩ); ±4.0%rdg ±4dgt (4MΩ); ±8.0%rdg ±4dgt (40MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±30Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V (AC A); CAT III 300V \/ CAT II 600V (AC\/DC V), Pollution Degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC), EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 120 hours (auto power off after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 × 68 × 20mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7107a-test-lead-1100mm\"\u003eTest leads (7107A)\u003c\/a\u003e, carrying case (9160), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2200 vs 2200R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2200-digital-clamp-meter\"\u003e2200\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2200R (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003eNo (average sensing)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.4%rdg ±6dgt (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (45–65Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current frequency range\u003c\/td\u003e\n\u003ctd\u003e45–65Hz\u003c\/td\u003e\n\u003ctd\u003e40Hz–1kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating (AC A)\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 300V \/ CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous measuring time\u003c\/td\u003e\n\u003ctd\u003eApprox. 350 hours\u003c\/td\u003e\n\u003ctd\u003eApprox. 120 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eBasic AC current checks with long battery life\u003c\/td\u003e\n\u003ctd\u003eNon-sinusoidal loads such as inverters and LED lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43000954454228,"sku":"KE 2200R","price":542.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kew_2200r_01.png?v=1769186599"},{"product_id":"kyoritsu-2200-digital-clamp-meter","title":"KYORITSU 2200 AC Digital Clamp Meter 1000A | KEW 2200","description":"\u003ch2\u003eKYORITSU 2200 AC Digital Clamp Meter 1000A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKyoritsu 2200 Digital Clamp Meter\u003c\/strong\u003e is a reliable and precise instrument for measuring AC current (up to 1000A), AC\/DC voltage and resistance. It measures AC current only, not DC current (average-sensing; the KEW 2200R is the True RMS version). The \u003cstrong\u003eKEW 2200\u003c\/strong\u003e provides safe clamp measurements without disconnecting circuits, making it suitable for electricians, technicians, and maintenance professionals. Its compact, ergonomic design ensures portability, while durable housing protects the device during field and workshop use. The clear digital display of the Kyoritsu 2200 Digital Clamp Meter delivers fast, consistent readings for accurate electrical testing in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/2200.png?v=1733495870\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Slim and Lightweight:\u003c\/strong\u003e Handy design for easy use and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTeardrop-Shaped Jaws:\u003c\/strong\u003e φ33mm jaws allow easy access to wires in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000A AC Clamp Meter:\u003c\/strong\u003e Handles high current measurements with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive DMM Function:\u003c\/strong\u003e Measures AC voltage, DC voltage, resistance, and includes a continuity buzzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuseless Protection:\u003c\/strong\u003e Electronic protection on Ω\/Continuity up to 600V ensures safety and durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Resolution:\u003c\/strong\u003e Achieves a resolution of 0.01A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 600V and IEC 61010-2-032 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 400.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.4%rdg ±6dgt (50\/60Hz); ±1.6%rdg ±6dgt (45 - 65Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.8%rdg ±7dgt (45 - 65Hz); ±2.3%rdg ±8dgt (65 - 500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400.0mV \/ 4.000V \/ 40.00V \/ 400.0V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt (excluding 400mV range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4.000kΩ \/ 40.00kΩ \/ 400.0kΩ \/ 4.000MΩ \/ 40.00MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±4dgt (0 - 400kΩ); ±4.0%rdg ±4dgt (4MΩ); ±8.0%rdg ±4dgt (40MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±30Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 600V (AC A); CAT III 300V \/ CAT II 600V (AC\/DC V), Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003eNot available (AC current only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 350 hours (auto power off after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 × 68 × 20mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7107a-test-lead-1100mm\"\u003eTest leads (7107A)\u003c\/a\u003e, carrying case (9160), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2200 vs 2200R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e2200 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2200r-digital-clamp-meter-with-true-rms-ke2200r-1000a-ac-and-600v-ranging\"\u003e2200R\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003eNo (average sensing)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.4%rdg ±6dgt (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (45–65Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current frequency range\u003c\/td\u003e\n\u003ctd\u003e45–65Hz\u003c\/td\u003e\n\u003ctd\u003e40Hz–1kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating (AC A)\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 300V \/ CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous measuring time\u003c\/td\u003e\n\u003ctd\u003eApprox. 350 hours\u003c\/td\u003e\n\u003ctd\u003eApprox. 120 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eBasic AC current checks with long battery life\u003c\/td\u003e\n\u003ctd\u003eNon-sinusoidal loads such as inverters and LED lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43000962154708,"sku":"KE 2200","price":443.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kew_2200__01.png?v=1769186604"},{"product_id":"fluke-302-digital-clamp-meter","title":"Fluke 302+ AC Clamp Meter 400A","description":"\u003cp\u003eThe Fluke 302+ is an entry-level AC clamp meter for simple, reliable current checks to 400A where True-RMS is not required. It also measures 600V AC\/DC voltage, resistance and continuity, and carries a CAT III 600V \/ CAT IV 300V rating with a 30mm jaw, backlit display and data hold.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current to 400A (±1.8%)\u003c\/li\u003e\n\u003cli\u003eAC and DC voltage to 600V\u003c\/li\u003e\n\u003cli\u003eResistance to 4000Ω with continuity beeper (≤70Ω)\u003c\/li\u003e\n\u003cli\u003e30mm jaw opening\u003c\/li\u003e\n\u003cli\u003eBacklit display and data hold; refresh more than 2 times per second\u003c\/li\u003e\n\u003cli\u003eRated CAT III 600V and CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e400.0A; ±1.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC \/ DC voltage\u003c\/td\u003e\n\u003ctd\u003e400V \/ 600V; ±1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e4000Ω; ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤70Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement type\u003c\/td\u003e\n\u003ctd\u003eAverage responding (not True-RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2 x 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e208 x 58.5 x 28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCAT III 600V, CAT IV 300V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 302+ Clamp Meter\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eFluke TL75 Hard Point test lead set\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e2 x AAA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eFluke TL75 Hard Point Test Lead Set\u003c\/a\u003e (replacement)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl175-twistguard%E2%84%A2-test-leads-set\"\u003eFluke TL175 TwistGuard Test Lead Set\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eFluke AC175 Alligator Clip Set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eQuick AC load checks on distribution boards and appliances\u003c\/li\u003e\n\u003cli\u003eAir-conditioning and motor current checks\u003c\/li\u003e\n\u003cli\u003eVoltage and continuity checks for building maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 300 Series Clamp Meter comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301b-clamp-meter\"\u003eFluke 301B\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301c-clamp-meter\"\u003eFluke 301C\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301d-clamp-meter\"\u003eFluke 301D\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-301e-clamp-meter\"\u003eFluke 301E\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 302+ (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-303-compact-clamp-meter\"\u003eFluke 303\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-305-true-rms-clamp-meter\"\u003eFluke 305\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance \u0026amp; frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e34mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AAA\u003c\/td\u003e\n\u003ctd\u003e2 x AA\u003c\/td\u003e\n\u003ctd\u003e2 x AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic AC checks to 600A\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS AC to 1000A\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 600A (solar, battery, automotive)\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 1000A\u003c\/td\u003e\n\u003ctd\u003eSimple 400A AC checks\u003c\/td\u003e\n\u003ctd\u003e600A AC on CAT III 600V circuits\u003c\/td\u003e\n\u003ctd\u003eHigh-current AC to 999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43006528913620,"sku":"FK 302+","price":589.7,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke-302-plus.jpg?v=1794535560"},{"product_id":"hioki-3280-10f-ac-clamp-meter","title":"Hioki AC Clamp Meter, 1000A AC, Slim Jaw, -25°C to 65°C, 3280-10F","description":"\u003ch1 data-start=\"840\" data-end=\"896\"\u003e\u003cstrong data-start=\"844\" data-end=\"896\"\u003eOverview Summary (HIOKI 3280-10F)\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eThe\u003cstrong data-start=\"902\" data-end=\"935\"\u003e HIOKI 3280-10F AC Clamp Meter\u003c\/strong\u003eare best-in-class measuring devices incorporating Hioki’ s expertise in current sensing technology. The 3280-10F is an average rectifying 1000A AC clamp meter that features a broad operating temperature range of -25°C to 65°C, thin and compact clamp core and optional flexible current sensor that you can attach to let you get into the tightest spots.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAT IV 300 V (Current)\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V (Current)\u003c\/li\u003e\n\u003cli\u003eCAT III 300 V (Voltage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"lyt-img-02 left bottom large-01\"\u003e\n\u003cdiv class=\"txt\"\u003e\n\u003ch2 class=\"hdg2-04\"\u003eUsing 3280 series AC clamp meters: Introduction to functionality and measurement methods\u003c\/h2\u003e\n\u003cp\u003eIn addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality.\u003cbr\u003eTheir compact size, low-profile design, and resistance to both rough handling and extreme temperatures make them essential tools for any electrician.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"box-movie-01 img\"\u003e\n\u003cdiv class=\"movie-inner\"\u003e\u003ciframe height=\"365\" width=\"670\" src=\"https:\/\/www.youtube.com\/embed\/qyQF6B34YDw?rel=0\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"hdg2-01\"\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"txt-keyword-01 col3\"\u003e\n\u003cli\u003e\u003cb\u003eMeasure the fundamental waveform component using the average rectified method\u003cbr\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eExpanded -25°C to 65°C operating temperature range\u003cbr\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eConnect the CT6280 flexible sensor to measure up to 4199 A in thick or paired wires\u003cbr\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eDrop proof design withstands drop from a height of 1 meter\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"lyt-img-02 left bottom large-01\"\u003e\n\u003cdiv class=\"box-movie-01 img\"\u003e\n\u003cdiv class=\"movie-inner\"\u003e\u003ciframe height=\"365\" width=\"670\" src=\"https:\/\/www.youtube.com\/embed\/Y4Rl_dX1Qsc?rel=0\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"lyt-img-02 right bottom large-01\"\u003e\n\u003cdiv class=\"txt\"\u003e\n\u003ch2 class=\"hdg2-04\"\u003eA pocket clamp meter that can use flexible sensors\u003c\/h2\u003e\n\u003cp\u003eWhen connected to an optional flexible current sensor, the 3280-10F can be used to measure the current flowing in pairs of wires or in tangled or complexly routed wires around which it was not possible to apply a clamp-on sensor in the past.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"img\"\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/www.hioki.com\/sites\/default\/files\/image\/2021-05\/client_upload_11_1456140408526_1.png\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"lyt-img-02 left bottom large-01\"\u003e\n\u003cdiv class=\"txt\"\u003e\n\u003ch2 class=\"hdg2-04\"\u003eEssential for electrical work: A thin card tester that fits in the pocket with all the capabilities of a clamp meter\u003c\/h2\u003e\n\u003cp\u003eThe 3280-10F delivers all the functionality of a clamp meter and card tester in the form factor of the latter. In addition to current measurement, this single instrument delivers voltage measurement, continuity check, and resistance measurement functionality.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"img\"\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/www.hioki.com\/sites\/default\/files\/image\/2021-05\/client_upload_11_1456140602888_1.png\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"lyt-img-02 right bottom large-01\"\u003e\n\u003cdiv class=\"txt\"\u003e\n\u003ch2 class=\"hdg2-04\"\u003eA tough, pocket-size clamp meter with an operating temperature range of -25°C to 65°C\u003c\/h2\u003e\n\u003cp\u003eThe 3280-10F inherits the drop-proof durability of the previous 3280-10 (making it able to withstand being dropped onto concrete from a height of 1 m) and expands that instrument’s operating temperature range to -25°C to 65°C (from the previous 0°C to 40°C). As a result, it can be used in even harsher environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"img\"\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/www.hioki.com\/sites\/default\/files\/image\/2021-05\/client_upload_11_1456140888197_1.png\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"hdg2-04\"\u003eBasic specifications\u003c\/h2\u003e\n\u003cdiv\u003eAccuracy guaranteed: 1 year\u003c\/div\u003e\n\u003cdiv class=\"tablefield-wrapper\" id=\"tablefield-wrapper-paragraph-32199-field_table_spec-0\"\u003e\n\u003cdiv class=\"table-scroll-01\"\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003ctable class=\"table-01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_0 col_0\"\u003eAC Current range\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_0 col_1\"\u003e41.99 to 1000 A, 3 ranges (50 Hz to 60 Hz, Average rectified),\u003cbr\u003eBasic accuracy: ±1.5 % rdg. ±5 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_1 col_0\"\u003eDC Voltage range\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_1 col_1\"\u003e419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_2 col_0\"\u003eAC Voltage range\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_2 col_1\"\u003e4.199 V to 600 V, 4 ranges\u003cbr\u003e(45 to 500 Hz, Average rectified),\u003cbr\u003eBasic accuracy: ±1.8 % rdg. ±7 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_3 col_0\"\u003eCrest factor\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_3 col_1\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_4 col_0\"\u003eResistance range\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_4 col_1\"\u003e419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_5 col_0\"\u003eOther functions\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_5 col_1\"\u003eContinuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_6 col_0\"\u003eDisplay\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_6 col_1\"\u003eLCD, max. 4199 dgt., Display refresh rate: 400 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_7 col_0\"\u003eEnvironmental protection\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_7 col_1\"\u003eIP40 dustproof and waterproof (while in storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_8 col_0\"\u003ePower supply\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_8 col_1\"\u003eCoin type lithium battery (CR2032) ×1, Continuous use 120 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_9 col_0\"\u003eCore jaw dia.\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_9 col_1\"\u003eφ 33 mm (1.30 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_10 col_0\"\u003eDimensions and mass\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_10 col_1\"\u003e57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_11 col_0\"\u003eIncluded accessories\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_11 col_1\"\u003eCARRYING CASE 9398 ×1, TEST LEAD L9208 ×1, Coin type lithium battery (CR2032) ×1, Instruction manual ×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"hdg2-04\"\u003eCT6280 Basic specifications\u003c\/h2\u003e\n\u003cdiv\u003eAccuracy guaranteed: 1 year\u003c\/div\u003e\n\u003cdiv class=\"tablefield-wrapper\" id=\"tablefield-wrapper-paragraph-32200-field_table_spec-0\"\u003e\n\u003cdiv class=\"table-scroll-01\"\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003ctable class=\"table-01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_0 col_0\"\u003eCore jaw dia.\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_0 col_1\"\u003eφ 130 mm (5.12 in) (Cable cross-section diameter: 5 mm (0.20 in); tip cap diameter: 7 mm (0.28 in))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_1 col_0\"\u003eAC Current\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_1 col_1\"\u003e419.9 A\/ 4199 A, 2 ranges (±3.0 % rdg. ±5 dgt.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_2 col_0\"\u003eCable length\u003c\/th\u003e\n\u003ctd colspan=\"6\" class=\"row_2 col_1\"\u003e800 mm (31.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"inner\"\u003e\u003cspan\u003eIncluded accessories (2)\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"item-01\"\u003e\n\u003cdiv class=\"item-inner\"\u003e\n\u003cdiv class=\"link\"\u003e\n\u003cdiv class=\"img-01\"\u003e\u003cimg alt=\"\" src=\"https:\/\/www.hioki.com\/sites\/default\/files\/image\/2021-05\/client_upload_11_1453425469032_1.png\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"data-01\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb class=\"title-01\"\u003eCARRYING CASE 9398\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-02\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"item-01\"\u003e\n\u003cdiv class=\"item-inner\"\u003e\n\u003cdiv class=\"link\"\u003e\n\u003cdiv class=\"img-01\"\u003e\u003cimg alt=\"\" src=\"https:\/\/www.hioki.com\/sites\/default\/files\/image\/2021-05\/client_upload_11_1445315707689_1.png\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"data-01\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb class=\"title-01\"\u003eTEST LEAD L9208\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-02\"\u003e\n\u003cp\u003e70 cm (2.30 ft) length\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"inner\"\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eHioki 3280-10F vs 3280-70F\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e3280-10F (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/hioki-3280-70f-digital-ac-clamp-meter-with-ct6280\"\u003e3280-70F\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhat you get\u003c\/td\u003e\n\u003ctd\u003eClamp meter only\u003c\/td\u003e\n\u003ctd\u003e3280-10F clamp meter plus CT6280 flexible current sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current (max.)\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e1000A (jaw); 4199A with CT6280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eφ33mm jaw\u003c\/td\u003e\n\u003ctd\u003eφ33mm jaw; φ130mm flexible loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible sensor\u003c\/td\u003e\n\u003ctd\u003eOptional, not included\u003c\/td\u003e\n\u003ctd\u003eCT6280: 419.9A \/ 4199A ranges, ±3.0% rdg ±5 dgt, 800mm cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eEveryday panel work on single cables up to 1000A\u003c\/td\u003e\n\u003ctd\u003eThick, bundled or hard-to-reach conductors up to 4199A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HIOKI","offers":[{"title":"Default Title","offer_id":43036785901780,"sku":"3280-10F","price":380.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Hioki_3280-10F.jpg?v=1769186634"},{"product_id":"proskit-mt-3266-3-1-2-hand-held-digital-clamp-meter","title":"Pro'sKit Digital Clamp Meter, 3½ Digit – MT-3266","description":"Model : PRO'SKIT MT-3266 3 1\/2 HAND HELD DIGITAL CLAMP METER\u003cbr\u003e\u003cbr\u003eDescription\u003cbr\u003e\u003cbr\u003eMT-3266 Hand Held Digital Clamp Meter Clamp meter is 3 1\/2-digit LCD and standard 9V battery operation for measuring DC voltage, AC and DC current, resistance and continuity test. All overload protection is provided. It is matching with 500 V insulation test attachment for insulation test function. The knob switch design makes manual operation workable \u0026amp; function selector, range selector and power switch are all on one knob. It is a good tool for electric measurement.\u003cbr\u003e\u003cbr\u003eFeatures\u003cbr\u003e\u003cbr\u003e3 1\/2 digits 1999 counts.\u003cbr\u003e\u003cbr\u003e0.8% best accuracy.\u003cbr\u003e\u003cbr\u003ePortable and simple one-hand operation.\u003cbr\u003e\u003cbr\u003eExtra function: data hold, low battery indication.\u003cbr\u003e\u003cbr\u003eMax. Jaw opening: max. 50mm.\u003cbr\u003e\u003cbr\u003eSpecifications\u003cbr\u003e\u003cbr\u003eDCV : 1,000V ±(0.8%+2d)\u003cbr\u003e\u003cbr\u003eACV :  750V ±(1.2%+4d)\u003cbr\u003e\u003cbr\u003eACA : 200\/1,000A ±(3.0%+5d)\u003cbr\u003e\u003cbr\u003eResistance\u003cbr\u003e\u003cbr\u003e200Ω ±(1.0%+3d),\u003cbr\u003e\u003cbr\u003e20kΩ ±(1.0%+1d)\u003cbr\u003e\u003cbr\u003eContinuity with beeper : Y\u003cbr\u003e\u003cbr\u003ePower Source :  NEDA1604\/6F22 (9V) x 1pcs (Not included)\u003cbr\u003e\u003cbr\u003eSize : 230 x 70 x 37 mm\u003cbr\u003e\u003cbr\u003eIndividual package : Double blister\u003cbr\u003e","brand":"PRO'SKIT","offers":[{"title":"Default Title","offer_id":43071857426644,"sku":"MT-3266","price":85.6,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/1cc265dd98d5e2dc105f18fe6a331cca.jpg?v=1769151765"},{"product_id":"kyoritsu-2433-leakage-clamp-meter","title":"KYORITSU 2433 Leakage Clamp Meter | KEW 2433","description":"\u003ch1 class=\"goods_name\"\u003eMODEL 2433 Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"755\" data-end=\"806\"\u003e\u003cstrong data-start=\"758\" data-end=\"806\"\u003eKYORITSU 2433 Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"808\" data-end=\"1437\"\u003eThe \u003cstrong data-start=\"812\" data-end=\"849\"\u003eKYORITSU 2433 Leakage Clamp Meter\u003c\/strong\u003e is engineered for precise detection and measurement of leakage currents in residential, commercial, and industrial electrical systems. Designed for technicians who need accuracy and stability, the KYORITSU 2433 Leakage Clamp Meter ensures safe troubleshooting, preventive maintenance, and insulation monitoring. Its compact jaw structure allows easy clamping on tightly packed cables, providing reliable performance even in complex environments. This instrument is an essential tool for electrical engineers and maintenance teams responsible for safety compliance and system diagnostics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Reduces the effects of harmonics for accurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Measurement Ranges:\u003c\/strong\u003e 40mA, 400mA, and 400A for versatile applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.01mA for detecting small leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates effectively between 20Hz and 1kHz (40Hz to 1kHz for 400A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Lightweight:\u003c\/strong\u003e Ideal for on-site inspections with convenient handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (40\/400mA); ±1%rdg ±5dgt (0 - 350A); ±2%rdg (350.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±10dgt [20Hz - 1kHz] (40\/400mA); ±2.5%rdg ±10dgt [40Hz - 1kHz] (0 - 350A); ±5%rdg [40Hz - 1kHz] (350.1 - 399.9A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC (Line\/Neutral); 300V AC\/DC (Earth)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø40mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eApprox. 10mA AC near a 15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz - 1kHz (40Hz - 1kHz for 400A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm × 81 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9097), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43072775258324,"sku":"KE 2433","price":2676.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/2916302be6eb045f215507dc6b9274e6.jpg?v=1770653697"},{"product_id":"kyoritsu-2003a-ac-dc-clamp-meters","title":"KYORITSU 2003A AC\/DC Digital Clamp Meter 2000A | KEW 2003A","description":"\u003ch2\u003eKYORITSU 2003A AC\/DC Digital Clamp Meter\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2003A AC\/DC Digital Clamp Meter\u003c\/strong\u003e is a high-precision instrument designed for safe and accurate measurement of AC and DC currents in residential, commercial, and industrial electrical systems. The KEW 2003A features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable and efficient operation. Its portability and performance make the KYORITSU 2003A ideal for electricians, maintenance technicians, and engineers who require precise current measurement for daily field operations.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Transformer Jaws:\u003c\/strong\u003e Measures currents on conductors up to Ø55mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Range:\u003c\/strong\u003e Measures both AC and DC currents up to 2000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminal:\u003c\/strong\u003e Enables connection to recorders for detailed data analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurements:\u003c\/strong\u003e Supports AC\/DC voltage, resistance, and continuity testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Readings:\u003c\/strong\u003e Offers a minimum resolution of 0.1A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power Save:\u003c\/strong\u003e Conserves battery life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 600V \/ CAT III 1000V for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e400A \/ 2000A (0 - 1000A)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt [50\/60Hz]; ±3%rdg ±4dgt [40 - 500Hz]; ±5%rdg ±4dgt [500Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e2000A (1001 - 1999A)\u003c\/td\u003e\n\u003ctd\u003e±3%rdg ±2dgt [50\/60Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e400A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e400V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt [50\/60Hz]; ±1.5%rdg ±4dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e400V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400Ω \/ 4000Ω\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e400Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC400mV (against AC\/DC400A); DC200mV (against AC\/DC2000A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ55mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKEW 2003A (Kyoritsu 2003A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V \/ CAT III 1000V; IEC 61010-031; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 × 105 × 49mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 530g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7107a-test-lead-1100mm\"\u003eTest leads (7107A)\u003c\/a\u003e, carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2002PA vs 2002R vs 2003A vs 2009R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2002pa-digital-clamp-meter\"\u003e2002PA\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2002r-ac-clamp-meter\"\u003e2002R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2003A (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current accuracy (400A range, mains frequency)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e10–4000Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 530g\u003c\/td\u003e\n\u003ctd\u003eApprox. 540g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders needing the best AC accuracy, with peak hold\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders, with peak hold\u003c\/td\u003e\n\u003ctd\u003eDC systems such as UPS, rectifiers and battery banks\u003c\/td\u003e\n\u003ctd\u003eDistorted AC\/DC loads where you also need frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43072894501076,"sku":"KE 2003A","price":1676.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2003A.jpg?v=1794534598"},{"product_id":"kyoritsu-2413r-leakage-clamp-meter","title":"KYORITSU 2413R Leakage Clamp Meter | KEW 2413R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2413R Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"865\" data-end=\"908\"\u003e\u003cstrong data-start=\"868\" data-end=\"906\"\u003eKYORITSU 2413R Leakage Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"909\" data-end=\"1361\"\u003eThe \u003cstrong data-start=\"913\" data-end=\"951\"\u003eKYORITSU 2413R Leakage Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC\/DC leakage current measurement. The KEW 2413R features a compact ergonomic design, clear digital display, and stable readings for reliable operation. Its portability and performance make the KYORITSU 2413R Leakage Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field testing, troubleshooting, and inspection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Transformer Jaws:\u003c\/strong\u003e Easily clamps on 3-phase systems for leakage current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Filter Switch:\u003c\/strong\u003e Reduces harmonic interference for precise readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Way Analog Output:\u003c\/strong\u003e Supports waveform and recorder outputs for advanced data logging and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Handles currents up to 1000A with excellent accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±5dgt (200mA \/ 2A \/ 20A); ±3.0%rdg ±5dgt (200A, 0 - 500A); ±5.5%rdg (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.8%rdg ±5dgt (200mA \/ 2A \/ 20A); ±2.0%rdg ±5dgt (200A, 0 - 500A); ±5.0%rdg (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e3.0 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø68mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOutput Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform Output\u003c\/td\u003e\n\u003ctd\u003eAC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003eDC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e1 × 6F22 (9V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 60 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 130 mm × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 600g (including battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9094), 1 × 6F22 (9V) battery, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e2WAY Output Cord (7073)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43072945619156,"sku":"KE 2413R","price":2962.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/737cf94be80f97174f607c2294cda44b.jpg?v=1770653804"},{"product_id":"kyoritsu-2031-ac-digital-clamp-meters","title":"KYORITSU 2031 AC Digital Clamp Meter 200A | KEW 2031","description":"\u003ch2\u003eKYORITSU 2031 AC Digital Clamp Meter 200A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2031 AC Digital Clamp Meter\u003c\/strong\u003e is a compact instrument designed for safe and accurate AC current measurement. The KEW 2031 features a compact ergonomic design, clear digital display, and stable readings for reliable operation. Its portability and performance make the KYORITSU 2031 ideal for electricians, maintenance technicians, and engineers performing field testing and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Measures AC currents up to 200A with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and easy to handle, perfect for fieldwork.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Measurement:\u003c\/strong\u003e Minimum resolution of 0.01A for accurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThin Clamp Jaws:\u003c\/strong\u003e φ24mm tear drop-shaped jaws allow clamping in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Measures currents with a frequency response of 40Hz - 1kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50\/60Hz); ±3%rdg ±10dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ24mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × LR44 (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e147 mm × 58.5 mm × 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9090), 2 × LR44 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073004962004,"sku":"KE 2031","price":686.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2031.jpg?v=1794535795"},{"product_id":"kyoritsu-2010-ac-dc-clamp-meters","title":"KYORITSU 2010 AC\/DC Digital Clamp Meter 20A | KEW 2010","description":"\u003ch2\u003eKYORITSU 2010 AC\/DC Digital Clamp Meter 20A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2010 AC\/DC Digital Clamp Meter\u003c\/strong\u003e is a high-sensitivity instrument designed for safe and accurate measurement of small AC and DC currents (current measurement only). The KEW 2010 features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2010 ideal for electricians, maintenance technicians, and engineers performing field testing and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Measures small currents with resolutions of 0.1mA (AC) and 1mA (DC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMiniature Design:\u003c\/strong\u003e Compact and lightweight for easy handling and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminal:\u003c\/strong\u003e Connects to recorders for detailed current analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates from DC to 2kHz for versatile measurement needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe for Low-Voltage Circuits:\u003c\/strong\u003e Designed for use on circuits below 60V AC\/DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt [50\/60Hz] (200mA); ±1.5%rdg ±8dgt [40Hz - 2kHz] (200mA); ±1%rdg ±2dgt [50\/60Hz] (2A); ±2.5%rdg ±10dgt [40Hz - 2kHz] (2\/20A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e2A \/ 20A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt (2A); ±1.5%rdg ±4dgt (20A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC, 40Hz - 2kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC200mV (against AC200mA\/2\/20A and DC2\/20A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ7.5mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eFor current measurement on circuits below 60V AC\/DC only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e6LR61 (9V) × 1 or AC Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142 × 64 × 26mm (Main Unit); 153 × 23 × 18mm (Clamp Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9095), 6LF22 (9V) × 1, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu AC\/DC Clamp Meter Series comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2033-clamp-meter\"\u003e2033\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2046r-clamp-meter\"\u003e2046R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2055-clamp-meter\"\u003e2055\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2056r-clamp-meter\"\u003e2056R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2010 (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e2000A\u003c\/td\u003e\n\u003ctd\u003e20A (from 200mA AC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ24mm\u003c\/td\u003e\n\u003ctd\u003eØ33mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ55mm\u003c\/td\u003e\n\u003ctd\u003eØ7.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \u0026amp; resistance\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; temperature\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCircuits ≤60V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003ePocket-size AC\/DC current checks in crowded panels\u003c\/td\u003e\n\u003ctd\u003eEveryday AC\/DC work plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 1000A on panels and DC systems\u003c\/td\u003e\n\u003ctd\u003e1000A AC\/DC plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eLarge feeders, UPS and battery banks with recorder output\u003c\/td\u003e\n\u003ctd\u003eLow AC\/DC currents on thin wires and control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073077215444,"sku":"KE 2010","price":2974.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2010.jpg?v=1794535414"},{"product_id":"kyoritsu-2434-leakage-clamp-meter","title":"KYORITSU 2434 AC Leakage Clamp Meter 100A | KEW 2434","description":"\u003ch2\u003eKYORITSU 2434 AC Leakage Clamp Meter 100A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2434 Leakage Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC leakage and load current measurement. The KEW 2434 offers a clear digital display, compact and ergonomic design, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2434 Leakage Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field testing and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Stray Magnetic Field Resistance:\u003c\/strong\u003e Delivers accurate results with minimal interference from external fields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Reduces harmonic effects for consistent and precise measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.1mA for detecting small leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight and easy to handle, suitable for fieldwork.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V requirements for safe usage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e400mA \/ 4A \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e400mA \/ 4A \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±4dgt [50\/60Hz]; ±3%rdg ±5dgt [40 - 400Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø28mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20mA AC max. near a φ15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e169 mm × 75 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9097), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu Leakage Clamp Meter Series comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2431-leakage-clamp-meter\"\u003e2431\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2432-leakage-clamp-meter\"\u003e2432\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2433-leakage-clamp-meter\"\u003e2433\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2433r-leakage-clamp-meter\"\u003e2433R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2434 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2413r-leakage-clamp-meter\"\u003e2413R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2413f-leakage-digital-clamp-meter\"\u003e2413F\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current ranges\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 200mA \/ 200A\u003c\/td\u003e\n\u003ctd\u003e4mA \/ 40mA \/ 100A\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e400mA \/ 4A \/ 100A\u003c\/td\u003e\n\u003ctd\u003e200mA – 1000A (5 ranges)\u003c\/td\u003e\n\u003ctd\u003e200mA – 1000A (5 ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ24mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ28mm\u003c\/td\u003e\n\u003ctd\u003eØ68mm\u003c\/td\u003e\n\u003ctd\u003eØ68mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform \/ recorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g\u003c\/td\u003e\n\u003ctd\u003eApprox. 290g\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003ctd\u003eApprox. 600g\u003c\/td\u003e\n\u003ctd\u003eApprox. 570g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003ePocket-size leakage checks\u003c\/td\u003e\n\u003ctd\u003eVery small leakage (0.001mA resolution)\u003c\/td\u003e\n\u003ctd\u003eLeakage plus load current to 400A\u003c\/td\u003e\n\u003ctd\u003eLeakage plus load current to 400A\u003c\/td\u003e\n\u003ctd\u003eCompact 100A leakage and load checks\u003c\/td\u003e\n\u003ctd\u003eClamping all 3 or 4 wires together, with outputs\u003c\/td\u003e\n\u003ctd\u003eClamping all 3 or 4 wires together, with outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073100087508,"sku":"KE 2434","price":1843.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2434.jpg?v=1794536389"},{"product_id":"kyoritsu-2009r-clamp-meter","title":"KYORITSU 2009R AC\/DC Digital Clamp Meter True RMS 2000A | KEW 2009R","description":"\u003ch2\u003eKYORITSU 2009R True RMS AC\/DC Digital Clamp Meter 2000A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2009R Clamp Meter\u003c\/strong\u003e is a precision instrument designed for accurate AC\/DC current measurement. The KEW 2009R features a compact, ergonomic design with a clear digital display and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2009R Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field measurements and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Instrument:\u003c\/strong\u003e Ensures accurate measurements of distorted waveforms and non-sinusoidal signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Handles AC and DC currents up to 2000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminal:\u003c\/strong\u003e Enables recorder connection for efficient data analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurements:\u003c\/strong\u003e Supports AC\/DC voltage, resistance, continuity testing, and frequency measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e Offers a minimum resolution of 0.1A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 600V \/ CAT III 1000V standards for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e400.0A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±3dgt (0 - 400.0A, 150 - 1700A) [45 - 66Hz]; ±2.0%rdg ±5dgt (20Hz - 1kHz); ±2.3%rdg ±3dgt (1701 - 2000A) [45 - 66Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e400.0A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e40.00V \/ 400.0V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt [45 - 66Hz]; ±1.5%rdg ±5dgt [20Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e40.00V \/ 400.0V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt (Electronic protection up to 600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 20 ±1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e10.0 - 4000Hz\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (Input sensitivity: Current \u0026gt;40A, Voltage \u0026gt;10V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC400mV (against AC\/DC400.0A); DC200mV (against AC\/DC2000A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ55mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V \/ CAT III 1000V, Pollution Degree 2; IEC 61010-031; IEC 61010-2-032; IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 540g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7107a-test-lead-1100mm\"\u003eTest leads (7107A)\u003c\/a\u003e, carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2002PA vs 2002R vs 2003A vs 2009R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2002pa-digital-clamp-meter\"\u003e2002PA\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2002r-ac-clamp-meter\"\u003e2002R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2003a-ac-dc-clamp-meters\"\u003e2003A\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2009R (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current accuracy (400A range, mains frequency)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e10–4000Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 530g\u003c\/td\u003e\n\u003ctd\u003eApprox. 540g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders needing the best AC accuracy, with peak hold\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders, with peak hold\u003c\/td\u003e\n\u003ctd\u003eDC systems such as UPS, rectifiers and battery banks\u003c\/td\u003e\n\u003ctd\u003eDistorted AC\/DC loads where you also need frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073106510036,"sku":"KE 2009R","price":2131.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2009R.jpg?v=1794535103"},{"product_id":"kyoritsu-2608a-analog-clamp-meter","title":"(Discontinued) KYORITSU 2608A Analogue Clamp Meter 300A","description":"\u003cdiv style=\"border:1px solid #f0b429;background:#fff8e1;padding:12px 16px;margin:0 0 16px;border-radius:6px;\"\u003e\u003cp style=\"margin:0;\"\u003e\u003cstrong\u003e⚠ Discontinued by manufacturer\u003c\/strong\u003e — no longer available. Contact us for a current Kyoritsu equivalent.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch1 class=\"goods_name\"\u003eMODEL 2608A AC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"842\" data-end=\"884\"\u003e\u003cstrong data-start=\"845\" data-end=\"882\"\u003eKYORITSU 2608A Analog Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"885\" data-end=\"1336\"\u003eThe \u003cstrong data-start=\"889\" data-end=\"926\"\u003eKYORITSU 2608A Analog Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC\/DC current measurements with an analog display. The KEW 2608A offers a compact, ergonomic design with clear scale readings, ensuring reliable operation. Its portability and analog simplicity make the KYORITSU 2608A Analog Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field measurements and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Range:\u003c\/strong\u003e Essential for testing emergency battery-operated power supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTear Drop-Shaped Jaws:\u003c\/strong\u003e Designed for ease of use and access in restricted spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Measures AC current, AC voltage, DC voltage, and resistance effectively.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Lightweight:\u003c\/strong\u003e Ergonomic design for portability and user convenience.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT III 300V standards for safe and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e6A \/ 15A \/ 60A \/ 150A \/ 300A\u003c\/td\u003e\n\u003ctd\u003e±3% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e150V \/ 300V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±3% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e60V\u003c\/td\u003e\n\u003ctd\u003e±3% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e1Ω \/ 10kΩ (25Ω \/ 250Ω mid-scale)\u003c\/td\u003e\n\u003ctd\u003e±2% of scale length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V, Pollution Degree 2; IEC 61010-2-031; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e1 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e193 mm × 78 mm × 39 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 275g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, fuse (8923, 0.5A\/600V) × 2, carrying case (9097), 1 × R6 (AA) battery, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073116602580,"sku":"KE 2608A","price":665.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/3daaebf294f0b058a69ddfd0686b63de.jpg?v=1770653829"},{"product_id":"fluke-319-clamp-meter","title":"Fluke 319 True-RMS AC\/DC Clamp Meter 1000A with Inrush \u0026 Frequency","description":"\u003cp\u003eThe Fluke 319 is a True-RMS AC\/DC clamp meter that measures up to 1000A AC and DC current through a large 37mm jaw. It adds inrush current and frequency measurement for motor and lighting work, plus 600V AC\/DC voltage, resistance and continuity, with a large backlit display.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC current and voltage for accurate readings on non-linear loads\u003c\/li\u003e\n\u003cli\u003eAC and DC current to 1000A, with a 40.00A range for 0.01A resolution on small loads\u003c\/li\u003e\n\u003cli\u003eInrush current (100ms integration) for motor start-up troubleshooting\u003c\/li\u003e\n\u003cli\u003eFrequency 5–500Hz\u003c\/li\u003e\n\u003cli\u003e37mm jaw opening for large conductors\u003c\/li\u003e\n\u003cli\u003eCAT III 600V, IP40, 1m drop tested\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 600.0A \/ 1000A; ±(1.6% + 6) at 40A (50–60Hz), ±(1.5% + 5) at 600A and 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e40.00A \/ 600.0A \/ 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage (20–500Hz)\u003c\/td\u003e\n\u003ctd\u003e600.0V; ±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e600.0V; ±(1% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω; ±(1% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤30Ω with beeper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5.0–500.0Hz; ±(0.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current\u003c\/td\u003e\n\u003ctd\u003e100ms integration time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 counts, backlit, low-battery indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5V AAA (IEC LR03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e234 x 75 x 34.8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e384g (with batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCAT III 600V\u003c\/li\u003e\n\u003cli\u003eCE; EN\/IEC 61010-1 and IEC 61010-2-032\u003c\/li\u003e\n\u003cli\u003eIP40; 1m drop test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 319 Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003e3 x AAA batteries (installed)\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke AC285 SureGrip Alligator Clips\u003c\/li\u003e\n\u003cli\u003eFluke TL223 SureGrip Electrical Test Lead Set\u003c\/li\u003e\n\u003cli\u003eFluke L206 Deluxe LED Hat Light\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotor start-up (inrush) and running current analysis\u003c\/li\u003e\n\u003cli\u003eSolar PV, battery bank and DC drive current measurement\u003c\/li\u003e\n\u003cli\u003eLarge feeder and distribution board load checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 310 \u0026amp; 320 Series True-RMS Clamp Meter comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-317-true-rms-clamp-meter\"\u003eFluke 317\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 319 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-323-true-rms-clamp-meter\"\u003eFluke 323\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-324-plus-true-clamp-meter\"\u003eFluke 324\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-325-true-rms-clamp-meter\"\u003eFluke 325\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5–500Hz\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e5–500Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance \u0026amp; temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJaw \/ max conductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003ctd\u003e37mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003ctd\u003e30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 600A\u003c\/td\u003e\n\u003ctd\u003eAC\/DC to 1000A with inrush for motors\u003c\/td\u003e\n\u003ctd\u003eSimple True-RMS AC checks\u003c\/td\u003e\n\u003ctd\u003eHVAC work needing temperature \u0026amp; capacitance\u003c\/td\u003e\n\u003ctd\u003eSolar, battery \u0026amp; drive work needing DC and frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43073117880532,"sku":"FK 319","price":1600.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke-319.jpg?v=1794535627"},{"product_id":"kyoritsu-2002r-ac-clamp-meter","title":"KYORITSU 2002R AC Digital Clamp Meter 2000A | KEW 2002R","description":"\u003cdiv\u003e\n\u003ch1\u003eKYORITSU 2002R AC Clamp Meter\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2002R AC Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC current measurements. The KEW 2002R features a compact, ergonomic design with a clear digital display and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2002R AC Clamp Meter ideal for electricians, maintenance technicians, and engineers performing daily field measurements.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe KYORITSU 2002R AC Clamp Meter delivers fast and accurate AC current readings in a lightweight, easy-to-use design. The KEW 2002R combines reliable measurement with ergonomic portability, making it perfect for troubleshooting, maintenance, and inspection tasks. Its robust construction ensures long-term durability in demanding electrical environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Measures AC currents up to 2000A with excellent accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Hold Function:\u003c\/strong\u003e Captures and holds peak values for transient signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Tear Drop Shaped Jaws:\u003c\/strong\u003e φ55mm jaws for easy clamping of conductors, even in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Minimum resolution of 0.1A ensures precise readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Measurement Options:\u003c\/strong\u003e Measures AC current, AC\/DC voltage, resistance, and more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e400A (0 - 400A)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±3dgt (45 - 65Hz); ±2.5%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (0 - 1500A)\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (45 - 65Hz); ±3%rdg ±5dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (1500 - 2000A)\u003c\/td\u003e\n\u003ctd\u003e±4%rdg (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (AC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt (45 - 65Hz); ±1.5%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400Ω \/ 4kΩ \/ 40kΩ \/ 400kΩ\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eDC400mV against AC400A; DC200mV against AC2000A\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ55mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e247 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7107a-test-lead-1100mm\"\u003eTest leads (7107A)\u003c\/a\u003e, carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2002PA vs 2002R vs 2003A vs 2009R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2002pa-digital-clamp-meter\"\u003e2002PA\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2002R (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2003a-ac-dc-clamp-meters\"\u003e2003A\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current accuracy (400A range, mains frequency)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e10–4000Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 530g\u003c\/td\u003e\n\u003ctd\u003eApprox. 540g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders and busbars, with peak hold\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders where you also need a recorder output\u003c\/td\u003e\n\u003ctd\u003eDC systems such as UPS, rectifiers and battery banks\u003c\/td\u003e\n\u003ctd\u003eDistorted AC\/DC loads where you also need frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Thailand\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073137279188,"sku":"KE 2002R","price":1796.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/13c3f73ad92620519250f9953d38baf5.jpg?v=1770653858"},{"product_id":"kyoritsu-2001a-digital-multimeter","title":"KYORITSU 2001A Digital Multimeter with AC\/DC Clamp Sensor ≤600V | KEW 2001A","description":"\u003ch2\u003eKYORITSU 2001A (KEW MATE) Digital Multimeter with AC\/DC Clamp Sensor 100A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2001A\u003c\/strong\u003e is a 600V digital multimeter with a built-in open AC\/DC clamp sensor that reads AC and DC current up to 100A without breaking the circuit. The slim open jaw takes conductors up to Ø10mm, and the pocket-size, heavy-duty body with test probe holster and test lead cap suits daily field work and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures up to 100A for both AC and DC currents with the open clamp sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Cable Protection:\u003c\/strong\u003e Features improved cable strength with robust protection for added durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and Heavy Duty:\u003c\/strong\u003e Pocket-sized design combined with a heavy-duty build ensures portability without sacrificing strength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Probe Holster:\u003c\/strong\u003e Test probe can be securely fixed to the holster for convenient storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e Equipped with a test lead cap to prevent short circuit accidents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlim Clamp Jaws:\u003c\/strong\u003e Open jaws are thin enough to clamp wires in tight spaces, offering flexibility for hard-to-reach areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e340.0mV \/ 3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e3.400V \/ 34.00V \/ 340.0V \/ 600V\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (50 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e100.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e100.0A\u003c\/td\u003e\n\u003ctd\u003e±2%rdg ±5dgt (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e340.0Ω \/ 3.400kΩ \/ 34.00kΩ \/ 340.0kΩ \/ 3.400MΩ \/ 34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (0 - 340kΩ); ±5%rdg ±5dgt (3.4MΩ); ±15%rdg ±5dgt (34MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 30 ±10Ω\u003c\/td\u003e\n\u003ctd\u003eWorks only on 340Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eAC A: 3.4Hz - 10kHz; AC V: 3.4Hz - 300kHz\u003c\/td\u003e\n\u003ctd\u003e±0.1%rdg ±1dgt (Current \u0026gt; 25A, Voltage \u0026gt; 30V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ10mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V \/ CAT II 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm × 92 mm × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eSoft carrying case (9107)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu KEW MATE 2000A \/ 2001A \/ 2012RA comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2000a-digital-multimeter-600v\"\u003e2000A\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2001A (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2012ra-digital-multimeter\"\u003e2012RA\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp sensor AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e60.0A\u003c\/td\u003e\n\u003ctd\u003e100.0A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 120.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ6mm\u003c\/td\u003e\n\u003ctd\u003eØ10mm\u003c\/td\u003e\n\u003ctd\u003eØ12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (max.)\u003c\/td\u003e\n\u003ctd\u003e34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e34.00MΩ\u003c\/td\u003e\n\u003ctd\u003e60.00MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; diode\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V \/ CAT II 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 210g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eSmall wires and control panels\u003c\/td\u003e\n\u003ctd\u003eGeneral electrical work up to 100A\u003c\/td\u003e\n\u003ctd\u003eWider current range plus capacitor and diode checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/MUSXQhAcfEI\" width=\"560\" height=\"315\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/kewmate_img02_en.jpg?v=1733479327\" alt=\"Kyoritsu KEW MATE clamp multimeter series\"\u003e\u003c\/p\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073137311956,"sku":"KE 2001A","price":996.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2001A.jpg?v=1794535618"},{"product_id":"kyoritsu-2127r-clamp-meter","title":"KYORITSU 2127R AC Digital Clamp Meter True RMS 1000A | KEW 2127R","description":"\u003ch2\u003eKYORITSU 2127R True RMS AC Digital Clamp Meter 1000A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2127R Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC current measurements in residential, commercial, and industrial electrical systems. The KEW 2127R features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2127R Clamp Meter ideal for electricians, maintenance technicians, and engineers who require precise AC current measurement in daily field tasks.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Safety Jaw:\u003c\/strong\u003e Designed for secure and safe current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e Over-moulded body allows convenient one-hand operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Backlit Display:\u003c\/strong\u003e Easy-to-read display with 0.01A resolution, ideal for low-light conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Auto-Ranging:\u003c\/strong\u003e Accurate measurements for 60A, 600A, and 1000A ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Hold Function:\u003c\/strong\u003e Captures inrush current for dynamic loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance and Diode Testing:\u003c\/strong\u003e Expands functionality for diverse applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Battery Life:\u003c\/strong\u003e Operates continuously for approximately 170 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Compliant with IEC 61010-1 CAT IV 300V \/ CAT III 600V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt [45 - 65Hz]; ±2.0%rdg ±5dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±2dgt [45 - 65Hz]; ±1.5%rdg ±4dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt (60V); ±1.2%rdg ±3dgt (600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ \/ 60.00kΩ \/ 600.0kΩ \/ 6.000MΩ \/ 40.00MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±5dgt (600Ω); ±2.0%rdg ±3dgt (6\/60\/600kΩ); ±3.0%rdg ±3dgt (6MΩ); ±5.0%rdg ±3dgt (40MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 90Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Test\u003c\/td\u003e\n\u003ctd\u003e1.000µF \/ 10.00µF \/ 100.0µF\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg ±15dgt (1µF); ±3.0%rdg ±10dgt (10\/100µF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e2.000V\u003c\/td\u003e\n\u003ctd\u003e±4%rdg ±5dgt (Open-circuit voltage: \u0026lt;3.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e999.9Hz \/ 9.999kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±0.1%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2 (EMC), IEC 60529 IP40, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 170 hours (NCV LED and backlight off; auto power save after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e204 mm × 81 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 230g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, carrying case (9079), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2007R vs 2117R vs 2127R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2007r-ac-digital-clamp-meter\"\u003e2007R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2117r-ac-clamp-meter\"\u003e2117R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2127R (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current ranges\u003c\/td\u003e\n\u003ctd\u003e600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (max.)\u003c\/td\u003e\n\u003ctd\u003e6.000kΩ\u003c\/td\u003e\n\u003ctd\u003e600.0kΩ\u003c\/td\u003e\n\u003ctd\u003e40.00MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNCV voltage detection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance, diode, frequency\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak hold (inrush)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eStraightforward AC load checks\u003c\/td\u003e\n\u003ctd\u003eEveryday electrical work with built-in voltage detection\u003c\/td\u003e\n\u003ctd\u003eMotor inrush checks and work in dim switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083515494612,"sku":"KE 2127R","price":986.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2127R.jpg?v=1794535779"},{"product_id":"kyoritsu-2056r-clamp-meter","title":"KYORITSU 2056R AC\/DC Digital Clamp Meter True RMS 1000A | KEW 2056R","description":"\u003ch2\u003eKYORITSU 2056R True RMS AC\/DC Digital Clamp Meter 1000A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2056R Clamp Meter\u003c\/strong\u003e is a high-precision instrument designed for safe and accurate AC\/DC current measurements in residential, commercial, and industrial electrical systems. The KEW 2056R features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable and efficient operation. Its portability and performance make the KYORITSU 2056R Clamp Meter ideal for electricians, maintenance technicians, and engineers who require precise current measurement in daily field tasks.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Voltage Detection:\u003c\/strong\u003e Red LED warns of the presence of AC voltage for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-Moulded Ergonomic Design:\u003c\/strong\u003e Provides a secure and comfortable grip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurement Capabilities:\u003c\/strong\u003e Supports AC\/DC current, AC\/DC voltage, resistance, continuity, diode, capacitance, temperature, and frequency measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Range:\u003c\/strong\u003e Measures AC\/DC currents up to 1000A with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT IV 600V for secure and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 500Hz); ±5.5%rdg ±5dgt (500Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600mV \/ 6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (600Ω - 6MΩ); ±5%rdg ±8dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds at 100Ω or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Check\u003c\/td\u003e\n\u003ctd\u003eTest voltage 0 - 2V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e400nF \/ 4μF \/ 40μF (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-50°C to +300°C (with Temperature Probe 8216)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz \/ 100Hz \/ 1kHz \/ 10kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1% - 99.9%\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ40mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKEW 2056R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMax. 6039 counts (frequency 9999; capacitance and temperature 4039)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V (Pollution Degree 2); IEC 61010-031; IEC 61010-2-032; IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 25mA; auto sleep approx. 15 minutes after last switch operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Conditions\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C, 85% RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C, 85% RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e254 × 82 × 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 310g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, carrying case (9094), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/ms\/products\/kyoritsu-8216-temperature-probe-leads\"\u003eTemperature probe (8216)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu AC\/DC Clamp Meter Series comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2033-clamp-meter\"\u003e2033\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2046r-clamp-meter\"\u003e2046R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2055-clamp-meter\"\u003e2055\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2056R (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2010-ac-dc-clamp-meters\"\u003e2010\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e2000A\u003c\/td\u003e\n\u003ctd\u003e20A (from 200mA AC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ24mm\u003c\/td\u003e\n\u003ctd\u003eØ33mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ55mm\u003c\/td\u003e\n\u003ctd\u003eØ7.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \u0026amp; resistance\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; temperature\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCircuits ≤60V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003ePocket-size AC\/DC current checks in crowded panels\u003c\/td\u003e\n\u003ctd\u003eEveryday AC\/DC work plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 1000A on panels and DC systems\u003c\/td\u003e\n\u003ctd\u003e1000A AC\/DC plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eLarge feeders, UPS and battery banks with recorder output\u003c\/td\u003e\n\u003ctd\u003eLow AC\/DC currents on thin wires and control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-8216-temperature-probe-leads\"\u003eKyoritsu 8216 Temperature Probe\u003c\/a\u003e – K-type probe for the temperature function (-50 to 300°C)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083517362388,"sku":"KE 2056R","price":1649.5,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2056R.jpg?v=1794536185"},{"product_id":"kyoritsu-2055-clamp-meter","title":"KYORITSU 2055 AC\/DC Digital Clamp Meter 1000A | KEW 2055","description":"\u003ch2\u003eKYORITSU 2055 AC\/DC Digital Clamp Meter 1000A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2055 Clamp Meter\u003c\/strong\u003e is a precision instrument designed for safe and accurate AC\/DC current measurements in residential, commercial, and industrial electrical systems. The KEW 2055 features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable and efficient operation. Its portability and performance make the KYORITSU 2055 Clamp Meter ideal for electricians, maintenance technicians, and engineers who require precise current measurement in daily field operations.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Voltage Detection:\u003c\/strong\u003e Red LED provides a clear warning of AC voltage presence for added safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e Double moulding ensures comfort during prolonged use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measurement Range:\u003c\/strong\u003e Capable of measuring up to 1000A AC\/DC with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurements:\u003c\/strong\u003e Supports AC\/DC current, AC\/DC voltage, resistance, continuity, diode, frequency and duty-cycle testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT IV 600V for secure operation in high-risk environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (50\/60Hz); ±3.0%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±4dgt (50\/60Hz); ±3.0%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600mV \/ 6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (600Ω - 6MΩ); ±5%rdg ±8dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds at 100Ω or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Check\u003c\/td\u003e\n\u003ctd\u003eTest voltage 0 - 2V\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz \/ 100Hz \/ 1kHz \/ 10kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003eACA (40 - 400Hz): ±0.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1% - 99.9%\u003c\/td\u003e\n\u003ctd\u003e±2.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ40mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKEW 2055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMax. 6039 counts (frequency 9999) with bar graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V (Pollution Degree 2), IEC 61010-031, IEC 61010-2-032, IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 12mA; auto sleep after approx. 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Conditions\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C, 85% RH or less (no condensation), altitude up to 2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C, 85% RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e254 × 82 × 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 310g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, carrying case (9094), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu AC\/DC Clamp Meter Series comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2033-clamp-meter\"\u003e2033\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2046r-clamp-meter\"\u003e2046R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2055 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2056r-clamp-meter\"\u003e2056R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2010-ac-dc-clamp-meters\"\u003e2010\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e2000A\u003c\/td\u003e\n\u003ctd\u003e20A (from 200mA AC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ24mm\u003c\/td\u003e\n\u003ctd\u003eØ33mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ55mm\u003c\/td\u003e\n\u003ctd\u003eØ7.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \u0026amp; resistance\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; temperature\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCircuits ≤60V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003ePocket-size AC\/DC current checks in crowded panels\u003c\/td\u003e\n\u003ctd\u003eEveryday AC\/DC work plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 1000A on panels and DC systems\u003c\/td\u003e\n\u003ctd\u003e1000A AC\/DC plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eLarge feeders, UPS and battery banks with recorder output\u003c\/td\u003e\n\u003ctd\u003eLow AC\/DC currents on thin wires and control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083522670804,"sku":"KE 2055","price":1146.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2055.jpg?v=1794534629"},{"product_id":"kyoritsu-2046r-clamp-meter","title":"KYORITSU 2046R AC\/DC Digital Clamp Meter True RMS 600A | KEW 2046R","description":"\u003ch2\u003eKYORITSU 2046R True RMS AC\/DC Digital Clamp Meter 600A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2046R Clamp Meter\u003c\/strong\u003e is a high-precision instrument designed for safe and accurate AC\/DC current measurements in residential, commercial, and industrial electrical systems. The KEW 2046R features a compact ergonomic design, clear digital display, and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2046R Clamp Meter ideal for electricians, technicians, and engineers who require precise current measurement for daily field tasks.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Voltage Detection:\u003c\/strong\u003e Red LED alerts the user to the presence of AC voltage for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble Moulding Design:\u003c\/strong\u003e Ensures a comfortable grip during prolonged use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurement Functions:\u003c\/strong\u003e Measures AC\/DC current, AC\/DC voltage, resistance, continuity, capacitance, temperature, and frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Offers a minimum resolution of 0.1A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT IV 600V for secure and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A\u003c\/td\u003e\n\u003ctd\u003e±2.0%rdg ±5dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 500Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e0 - 600.0A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt (50\/60Hz); ±3.5%rdg ±5dgt (40 - 400Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e600mV \/ 6V \/ 60V \/ 600V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (600Ω - 6MΩ); ±5%rdg ±8dgt (60MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e400nF \/ 4μF \/ 40μF (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-50°C to +300°C (with Temperature Probe 8216)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10Hz \/ 100Hz \/ 1kHz \/ 10kHz (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1% - 99.9%\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V; IEC 61010-031; IEC 61010-2-032; IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e243 mm × 77 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 300g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003eTest leads (7066A)\u003c\/a\u003e, carrying case (9094), instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/ms\/products\/kyoritsu-8216-temperature-probe-leads\"\u003eTemperature probe (8216)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu AC\/DC Clamp Meter Series comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2033-clamp-meter\"\u003e2033\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2046R (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2055-clamp-meter\"\u003e2055\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2056r-clamp-meter\"\u003e2056R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2010-ac-dc-clamp-meters\"\u003e2010\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e2000A\u003c\/td\u003e\n\u003ctd\u003e20A (from 200mA AC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ24mm\u003c\/td\u003e\n\u003ctd\u003eØ33mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ55mm\u003c\/td\u003e\n\u003ctd\u003eØ7.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \u0026amp; resistance\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; temperature\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCircuits ≤60V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003ePocket-size AC\/DC current checks in crowded panels\u003c\/td\u003e\n\u003ctd\u003eEveryday AC\/DC work plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 1000A on panels and DC systems\u003c\/td\u003e\n\u003ctd\u003e1000A AC\/DC plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eLarge feeders, UPS and battery banks with recorder output\u003c\/td\u003e\n\u003ctd\u003eLow AC\/DC currents on thin wires and control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083524571348,"sku":"KE 2046R","price":1373.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2046R.jpg?v=1794535270"},{"product_id":"kyoritsu-2033-clamp-meter","title":"KYORITSU 2033 AC\/DC Digital Clamp Meter 300A | KEW 2033","description":"\u003ch2\u003eKYORITSU 2033 AC\/DC Digital Clamp Meter 300A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2033 Clamp Meter\u003c\/strong\u003e is designed for precise AC\/DC current measurements in residential, commercial, and industrial settings. Compact and lightweight, it ensures safe, reliable readings for electricians, technicians, and maintenance professionals. Its ergonomic design provides comfort during prolonged use.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall and Lightweight:\u003c\/strong\u003e Compact design for ease of handling and portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Current Measurement:\u003c\/strong\u003e Measures currents up to 300A with high precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-Ranging Function:\u003c\/strong\u003e Automatically adjusts to the optimal range for accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Adjustment Button:\u003c\/strong\u003e Allows quick and easy DC current zeroing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Complies with IEC 61010-1 CAT III 300V for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e40A \/ 300A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±4dgt [50\/60Hz] (0 - 40A); ±2.5%rdg ±4dgt [20Hz - 1kHz] (0 - 40A); ±1.5%rdg ±4dgt [50\/60Hz] (20 - 200A); ±2.5%rdg ±4dgt [20Hz - 1kHz] (20 - 200A); ±3.5%rdg [50\/60Hz] (200 - 300A); ±4%rdg [20Hz - 1kHz] (200 - 300A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e40A \/ 300A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±4dgt (0 - ±40A); ±1.5%rdg ±4dgt (±20 - ±200A); ±3%rdg (±200 - ±300A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC, 20Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ24mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × LR44 (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e147 mm × 59 mm × 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9090), 2 × LR44 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu AC\/DC Clamp Meter Series comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e2033 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2046r-clamp-meter\"\u003e2046R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2055-clamp-meter\"\u003e2055\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2056r-clamp-meter\"\u003e2056R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2010-ac-dc-clamp-meters\"\u003e2010\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC\/DC current\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003ctd\u003e2000A\u003c\/td\u003e\n\u003ctd\u003e20A (from 200mA AC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ24mm\u003c\/td\u003e\n\u003ctd\u003eØ33mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ55mm\u003c\/td\u003e\n\u003ctd\u003eØ7.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \u0026amp; resistance\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e– (current only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance \u0026amp; temperature\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 300V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCircuits ≤60V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003ePocket-size AC\/DC current checks in crowded panels\u003c\/td\u003e\n\u003ctd\u003eEveryday AC\/DC work plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 1000A on panels and DC systems\u003c\/td\u003e\n\u003ctd\u003e1000A AC\/DC plus capacitor and temperature checks\u003c\/td\u003e\n\u003ctd\u003eLarge feeders, UPS and battery banks with recorder output\u003c\/td\u003e\n\u003ctd\u003eLow AC\/DC currents on thin wires and control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083526504660,"sku":"KE 2033","price":1355.7,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2033.jpg?v=1794535294"},{"product_id":"kyoritsu-2432-leakage-clamp-meter","title":"KYORITSU 2432 AC Leakage Clamp Meter 4mA–100A | KEW 2432","description":"\u003ch2\u003eKYORITSU 2432 AC Leakage Clamp Meter 4mA–100A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2432 Leakage Clamp Meter\u003c\/strong\u003e is a professional-grade instrument designed for accurate leakage current measurement in residential, commercial, and industrial electrical systems. The \u003cstrong\u003eKEW 2432\u003c\/strong\u003e features an ergonomic design, easy-to-read digital display, and stable readings for safe and reliable operation. Its compact size and high performance make the \u003cstrong\u003eKYORITSU 2432 Leakage Clamp Meter\u003c\/strong\u003e a dependable tool for electricians, maintenance technicians, and engineers requiring precise current measurements in daily field operations.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Selector Switch:\u003c\/strong\u003e Reduces harmonic effects for precise measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Measurement Ranges:\u003c\/strong\u003e 4mA, 40mA, and 100A to cover diverse applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Sensitivity:\u003c\/strong\u003e Minimum resolution of 0.001mA for detecting minute leakage currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Response:\u003c\/strong\u003e Operates effectively across 20Hz to 1kHz (40Hz to 1kHz for 100A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards Compliance:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for safe and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e4mA \/ 40mA \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt (4\/40mA); ±1%rdg ±5dgt (0 - 80A); ±5%rdg (80.1 - 100A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e4mA \/ 40mA \/ 100A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±5dgt [50\/60Hz]; ±2.5%rdg ±10dgt [20Hz - 1kHz] (4\/40mA); ±1%rdg ±5dgt [50\/60Hz]; ±2.5%rdg ±10dgt [40Hz - 1kHz] (0 - 80A); ±5%rdg [50\/60Hz]; ±10%rdg [40Hz - 1kHz] (80.1 - 100A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e600V AC\/DC (Line\/Neutral); 300V AC\/DC (Earth)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø40mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eApprox. 2mA AC near a 15mm conductor carrying 100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e20Hz - 1kHz (40Hz - 1kHz for 100A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm × 81 mm × 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 290g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9097), 2 × R03 batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu Leakage Clamp Meter Series comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2431-leakage-clamp-meter\"\u003e2431\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2432 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2433-leakage-clamp-meter\"\u003e2433\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2433r-leakage-clamp-meter\"\u003e2433R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2434-leakage-clamp-meter\"\u003e2434\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2413r-leakage-clamp-meter\"\u003e2413R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2413f-leakage-digital-clamp-meter\"\u003e2413F\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current ranges\u003c\/td\u003e\n\u003ctd\u003e20mA \/ 200mA \/ 200A\u003c\/td\u003e\n\u003ctd\u003e4mA \/ 40mA \/ 100A\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e40mA \/ 400mA \/ 400A\u003c\/td\u003e\n\u003ctd\u003e400mA \/ 4A \/ 100A\u003c\/td\u003e\n\u003ctd\u003e200mA – 1000A (5 ranges)\u003c\/td\u003e\n\u003ctd\u003e200mA – 1000A (5 ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003eØ24mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ40mm\u003c\/td\u003e\n\u003ctd\u003eØ28mm\u003c\/td\u003e\n\u003ctd\u003eØ68mm\u003c\/td\u003e\n\u003ctd\u003eØ68mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform \/ recorder output\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 120g\u003c\/td\u003e\n\u003ctd\u003eApprox. 290g\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g\u003c\/td\u003e\n\u003ctd\u003eApprox. 270g\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g\u003c\/td\u003e\n\u003ctd\u003eApprox. 600g\u003c\/td\u003e\n\u003ctd\u003eApprox. 570g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003ePocket-size leakage checks\u003c\/td\u003e\n\u003ctd\u003eVery small leakage (0.001mA resolution)\u003c\/td\u003e\n\u003ctd\u003eLeakage plus load current to 400A\u003c\/td\u003e\n\u003ctd\u003eLeakage plus load current to 400A\u003c\/td\u003e\n\u003ctd\u003eCompact 100A leakage and load checks\u003c\/td\u003e\n\u003ctd\u003eClamping all 3 or 4 wires together, with outputs\u003c\/td\u003e\n\u003ctd\u003eClamping all 3 or 4 wires together, with outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083543249108,"sku":"KE 2432","price":3010.4,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2432.jpg?v=1794536390"},{"product_id":"kyoritsu-2413f-leakage-digital-clamp-meter","title":"KYORITSU 2413F Leakage Clamp Meter | KEW 2413F","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2413F Leakage Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"832\" data-end=\"885\"\u003e\u003cstrong data-start=\"837\" data-end=\"883\"\u003eKYORITSU 2413F Leakage Digital Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"886\" data-end=\"1483\"\u003eThe \u003cstrong data-start=\"890\" data-end=\"936\"\u003eKYORITSU 2413F Leakage Digital Clamp Meter\u003c\/strong\u003e is a high-precision instrument designed to measure leakage current safely and accurately in residential, commercial, and industrial electrical systems. The \u003cstrong data-start=\"1093\" data-end=\"1106\"\u003eKEW 2413F\u003c\/strong\u003e features a compact, ergonomic design with true RMS measurement capability, ensuring stable and reliable readings. With its easy-to-read digital display, the \u003cstrong data-start=\"1264\" data-end=\"1310\"\u003eKYORITSU 2413F Leakage Digital Clamp Meter\u003c\/strong\u003e is ideal for electricians, maintenance technicians, and installation professionals who require dependable performance and precise current measurement in everyday field use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Transformer Jaws:\u003c\/strong\u003e Measures leakage current in 3-phase systems with ease.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Filter Switch:\u003c\/strong\u003e Minimizes harmonic interference for accurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Way Analog Output:\u003c\/strong\u003e Supports waveform and recorder connections for data logging and analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e Handles currents up to 1000A with precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Safety Standards:\u003c\/strong\u003e Certified to IEC 61010-1 CAT III 300V for secure and reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA) [50\/60Hz]\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt (200mA \/ 2A \/ 20A); ±2%rdg ±2dgt (200A, 0 - 500A); ±5.5%rdg (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (WIDE)\u003c\/td\u003e\n\u003ctd\u003e200mA \/ 2A \/ 20A \/ 200A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt [50\/60Hz], ±3%rdg ±2dgt [40Hz - 1kHz] (200mA \/ 2A \/ 20A); ±1.5%rdg ±2dgt [50\/60Hz], ±3.5%rdg ±2dgt [40Hz - 1kHz] (200A, 0 - 500A); ±5%rdg [50\/60Hz], ±10%rdg [40Hz - 1kHz] (501 - 1000A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eMax Ø68mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect of External Magnetic Field\u003c\/td\u003e\n\u003ctd\u003eφ15mm 100A\u003c\/td\u003e\n\u003ctd\u003e10mA AC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOutput Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform Output\u003c\/td\u003e\n\u003ctd\u003eAC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003eDC200mV against the maximum value of each range (1000A range is 100mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 300V; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e1 × 6F22 (9V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 60 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 130 mm × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 570g (including battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eCarrying case (9094), 1 × 6F22 (9V) battery, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e2WAY Output Cord (7073)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMade In: Japan\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083543281876,"sku":"KE 2413F","price":2878.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/cad6207fcab04c7ee67d2ca0af8756c5.jpg?v=1770653877"},{"product_id":"kyoritsu-2117r-ac-clamp-meter","title":"KYORITSU 2117R AC Digital Clamp Meter True RMS 1000A | KEW 2117R","description":"\u003ch2\u003eKYORITSU 2117R Digital AC Clamp Meter with True-RMS: The 1000A Gold Standard\u003c\/h2\u003e\n\u003cp\u003eThe \u003cb\u003eKyoritsu 2117R\u003c\/b\u003e is the go-to \"workhorse\" for \u003cb\u003eelectricians, HVAC engineers, and industrial maintenance teams\u003c\/b\u003e. Built to handle high-demand environments, it allows you to measure up to 1000A AC safely without interrupting the circuit. Whether you are troubleshooting industrial motors or complex commercial panels, this True RMS meter ensures accuracy even in the presence of electronic noise and harmonics.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e1000A True RMS:\u003c\/b\u003e Accurate readings on non-sinusoidal loads like LED systems and motor inverters, with auto-ranging 60\/600\/1000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIntegrated NCV Sensor:\u003c\/b\u003e Built-in Non-Contact Voltage detection for instant safety checks before you touch any wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSlim Tear-Drop Jaws:\u003c\/b\u003e Conductor size up to ø33mm; shape designed to reach into tight, crowded cable bundles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOne-Handed Operation:\u003c\/b\u003e Ergonomic over-moulded body provides a secure, comfortable grip for all-day field use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLarge Display:\u003c\/b\u003e Easy-to-read display with 0.01A resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLong Battery Life:\u003c\/b\u003e Approx. 170 hours of continuous measurement on 2 × AAA batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe height=\"315\" width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/RKfTjloDrZM\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±4dgt [45 - 65Hz]; ±2.0%rdg ±5dgt [40Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±2dgt [45 - 65Hz] (600V); ±1.5%rdg ±4dgt [40Hz - 1kHz] (60\/600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e60.00V \/ 600.0V (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt (60V); ±1.2%rdg ±3dgt (600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 6.000kΩ \/ 60.00kΩ \/ 600.0kΩ (Auto-ranging)\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±5dgt (600Ω); ±2.0%rdg ±3dgt (6\/60\/600kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 90Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eØ33mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V, Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, IEC 61326-2-2 (EMC), IEC 60529 IP40, EN 50581 (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R03\/LR03 (AAA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Measuring Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 170 hours (NCV LED off; auto power save after approx. 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e204 × 81 × 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003e7066A\u003c\/a\u003e), carrying case (9079), 2 × R03 (AAA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2007R vs 2117R vs 2127R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2007r-ac-digital-clamp-meter\"\u003e2007R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e2117R (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2127r-clamp-meter\"\u003e2127R\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current ranges\u003c\/td\u003e\n\u003ctd\u003e600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A\u003c\/td\u003e\n\u003ctd\u003e60.00A \/ 600.0A \/ 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003ctd\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (max.)\u003c\/td\u003e\n\u003ctd\u003e6.000kΩ\u003c\/td\u003e\n\u003ctd\u003e600.0kΩ\u003c\/td\u003e\n\u003ctd\u003e40.00MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNCV voltage detection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance, diode, frequency\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak hold (inrush)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eStraightforward AC load checks\u003c\/td\u003e\n\u003ctd\u003eEveryday electrical work with built-in voltage detection\u003c\/td\u003e\n\u003ctd\u003eMotor inrush checks and work in dim switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eKyoritsu 2117R Digital Clamp Meter\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/kyoritsu-7066a-test-leads-1100mm\"\u003e7066A Test Leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e9079 Carrying Case\u003c\/li\u003e\n\u003cli\u003e2 x AAA Batteries (R03)\u003c\/li\u003e\n\u003cli\u003eInstruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose Kyoritsu \u0026amp; This Model?\u003c\/h2\u003e\n\u003cp\u003eKyoritsu is a world leader in Japanese testing technology. Users choose the \u003cb\u003e2117R\u003c\/b\u003e because it is the benchmark for durability. While most clamp meters are bulky, this model combines a high 1000A capacity with a slim, ergonomic frame built for daily industrial use.\u003c\/p\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083598528724,"sku":"KE 2117R","price":422.7,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu_2117r_01.png?v=1775838602"},{"product_id":"kyoritsu-2002pa-digital-clamp-meter","title":"KYORITSU 2002PA AC Digital Clamp Meter 2000A | KEW 2002PA","description":"\u003ch2\u003eKYORITSU 2002PA AC Digital Clamp Meter 2000A\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKYORITSU 2002PA digital clamp meter\u003c\/strong\u003e is a precision instrument for measuring AC current without disconnecting circuits. It ensures safe, reliable, and accurate readings for electricians, engineers, and maintenance personnel in industrial, commercial, and residential applications.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/27db10f7d1e062c41c5703ce43814177_c025c159-f96a-4b6f-ac7f-cb31cb1c1a64.jpg?v=1763291899\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Output:\u003c\/strong\u003e Output terminal for connection to a recorder (optional 7256 output cord).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Capable of measuring AC currents up to 2000A with high accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Hold Function:\u003c\/strong\u003e Captures transient peak values for accurate measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Tear Drop Shaped Jaws:\u003c\/strong\u003e φ55mm jaws are designed for easy clamping of thick conductors in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Minimum resolution of 0.1A ensures precision even in low-current measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e The clamp meter is compact yet powerful, perfect for industrial and fieldwork use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e400A (0 - 400A)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (50\/60Hz); ±2%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (0 - 1500A)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt (50\/60Hz); ±3%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (AC A)\u003c\/td\u003e\n\u003ctd\u003e2000A (1500 - 2000A)\u003c\/td\u003e\n\u003ctd\u003e±3.0%rdg (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (AC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt (50\/60Hz); ±1.5%rdg ±3dgt (40Hz - 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DC V)\u003c\/td\u003e\n\u003ctd\u003e40V \/ 400V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400Ω \/ 4kΩ \/ 40kΩ \/ 400kΩ\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 50 ±35Ω\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e40Hz - 1kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC400mV (against AC400A); DC200mV (against AC2000A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003eφ55mm max.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT III 600V \/ CAT II 1000V; IEC 61010-2-031; IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e247 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/ms\/products\/kyoritsu-7107a-test-lead-1100mm\"\u003eTest leads (7107A)\u003c\/a\u003e, carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in Thailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKyoritsu 2002PA vs 2002R vs 2003A vs 2009R comparison\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e2002PA (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2002r-ac-clamp-meter\"\u003e2002R\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2003a-ac-dc-clamp-meters\"\u003e2003A\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/kyoritsu-2009r-clamp-meter\"\u003e2009R\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current accuracy (400A range, mains frequency)\u003c\/td\u003e\n\u003ctd\u003e±1%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±3dgt\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e10–4000Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V \/ CAT II 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 470g\u003c\/td\u003e\n\u003ctd\u003eApprox. 530g\u003c\/td\u003e\n\u003ctd\u003eApprox. 540g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders needing the best AC accuracy, with peak hold\u003c\/td\u003e\n\u003ctd\u003eLarge AC feeders, with peak hold\u003c\/td\u003e\n\u003ctd\u003eDC systems such as UPS, rectifiers and battery banks\u003c\/td\u003e\n\u003ctd\u003eDistorted AC\/DC loads where you also need frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43083598725332,"sku":"KE 2002PA","price":1140.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Kyoritsu-2002PA.jpg?v=1794535995"},{"product_id":"oxford-oxd5161725d-auto-range-digital-clamp-meter-2000a-ac-dc","title":"OXFORD OXD5161725D AUTO RANGE DIGITAL CLAMP METER 2000A AC\/DC","description":"\u003cp\u003eThe UT220 is a 1999 count AC\u0026amp;DC digital clamp meter that can ensure stable performance, higher degree of safety and reliability to users. It is designed with over-load protection for all ranges, perfect for all professionals measuring currents up to 2000A.\u003c\/p\u003e\n\n\u003cp\u003eNotes\u003cbr\u003e\n• Battery not included\u003cbr\u003e\n \u003c\/p\u003e\n\n\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003ch6\u003eAdditional Features\u003c\/h6\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2000 Display Count\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003ch6\u003eBrand\u003c\/h6\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003eOxford\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003ch6\u003eean\u003c\/h6\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e5036140467590\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003ch6\u003eIncludes\u003c\/h6\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCarrying Bag Gift Box Operating Manual\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003ch6\u003eMFR Part No.\u003c\/h6\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003eUT220\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003ch6\u003eWeight\u003c\/h6\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e390g\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"OXFORD","offers":[{"title":"Default Title","offer_id":43129548341460,"sku":"OXD5161725D","price":949.3,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/202208080411555f08b7a6a28f3ff5ff8f0cc6ca5eaf62.png?v=1770654328"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/collections\/Clamp_Meter_Categories-2227952.png?v=1762281347","url":"https:\/\/techno.my\/ms\/collections\/clamp-meters.oembed?page=3","provider":"Techno Tools \u0026 Equipment","version":"1.0","type":"link"}