{"title":"Fluke SUPERDEAL – Buy X","description":"\u003cp\u003eBuy any tool digital multimeter or testing equipment on this page and choose a free gift from our SUPERDEAL gift range. One free gift per unit purchased, added to your cart at RM0.00, while stocks last.\u003c\/p\u003e","products":[{"product_id":"fluke-1535-2500v-insulation-resistance-meter-digital-high-voltage-meg","title":"Fluke 1535 High Voltage Insulation Tester 2500V","description":"\u003cstyle\u003e \/* Scoped styles for the product description *\/ .product-description { font-family: Arial, sans-serif; line-height: 1.6; } .product-description .highlight { color: #6633ff; font-weight: bold; } .product-description .offer { color: #e74c3c; font-weight: bold; } .product-description table { width: 100%; border-collapse: collapse; margin: 20px 0; } .product-description table, .product-description th, .product-description td { border: 1px solid #ddd; } .product-description th, .product-description td { padding: 8px; text-align: left; } .product-description th { background-color: #f4f4f4; } .product-description .section-title { color: #333; margin-top: 20px; } \u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 1535 Insulation Resistance Tester\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 1535 2500V Insulation Resistance Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 1535 2500V Insulation Resistance Meter\u003c\/strong\u003e is a high-precision tool designed for safe and accurate insulation testing in electrical systems. It measures insulation resistance up to 2500 V, helping electricians and maintenance professionals detect potential insulation failures in cables, transformers, and motors before they cause downtime or damage. Compact and reliable, the \u003cstrong\u003eFLUKE 1535 2500V Insulation Resistance Meter\u003c\/strong\u003e is suitable for industrial, commercial, and field applications.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable test voltages: \u003cstrong\u003e250 V, 500 V, 1000 V, and 2500 V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to \u003cstrong\u003e500 GΩ\u003c\/strong\u003e for thorough analysis.\u003c\/li\u003e\n\u003cli\u003eAutomatic \u003cstrong\u003ePolarization Index (PI)\u003c\/strong\u003e and \u003cstrong\u003eDielectric Absorption Ratio (DAR)\u003c\/strong\u003e calculations to minimize environmental influence.\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong\u003e1,300 measurements\u003c\/strong\u003e at 2,500 V on a single charge.\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V rating for enhanced operator safety.\u003c\/li\u003e\n\u003cli\u003eShort circuit current of \u0026gt;2 mA for stable resistance measurements.\u003c\/li\u003e\n\u003cli\u003eBuilt-in warning for energized circuits above 30 V.\u003c\/li\u003e\n\u003cli\u003eDurable, portable design for field and factory floor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1535 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003e8 AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e73.5 mm x 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e8 AA alkaline cells, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e184 mm x 211 mm x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e≤80 % RH (10 °C to 30 °C), ≤50 % RH (30 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 2000 m; Storage: 12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529 IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInsulation Resistance Testing:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Voltage\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Measurement:\u003c\/strong\u003e 1 nA to 2 mA, ±20% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Measurement:\u003c\/strong\u003e 0.01 μF to 2.00 μF, ±15% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarning Range for Energized Circuits:\u003c\/strong\u003e \u0026gt;30 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e \u0026gt;2 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":42997985312980,"sku":"FK 1535\/APAC","price":9154.7,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/f6a95b8d6de409f2411fe683e778655d.jpg?v=1769185319"},{"product_id":"fluke-1537-2500v-insulation-resistance-meter-digital-high-voltage-meg","title":"Fluke 1537 High Voltage Insulation Tester 2500V","description":"\u003cstyle\u003e \/* Scoped styles for the product description *\/ .product-description { font-family: Arial, sans-serif; line-height: 1.6; } .product-description .highlight { color: #6633ff; font-weight: bold; } .product-description .offer { color: #e74c3c; font-weight: bold; } .product-description table { width: 100%; border-collapse: collapse; margin: 20px 0; } .product-description table, .product-description th, .product-description td { border: 1px solid #ddd; } .product-description th, .product-description td { padding: 8px; text-align: left; } .product-description th { background-color: #f4f4f4; } .product-description .section-title { color: #333; margin-top: 20px; } \u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 1537 Insulation Resistance Tester\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e is a high-voltage testing tool designed for precise insulation resistance measurements in electrical systems. It allows maintenance professionals and electricians to verify the integrity of insulation on cables, transformers, and motors. With a testing voltage up to 2500 V, the \u003cstrong\u003eFLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e ensures safety and reliability while identifying potential insulation failures before they cause operational issues.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features of FLUKE 1537 2500V Insulation Resistance Meter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable test voltages: \u003cstrong\u003e250 V, 500 V, 1000 V, and 2500 V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to \u003cstrong\u003e500 GΩ\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of \u003cstrong\u003ePI\u003c\/strong\u003e, \u003cstrong\u003eDAR\u003c\/strong\u003e, and \u003cstrong\u003eDielectric Discharge (DD)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFine-tunable test voltages in \u003cstrong\u003e100 V increments\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V rating for enhanced safety.\u003c\/li\u003e\n\u003cli\u003eShort circuit current of \u003cstrong\u003e\u0026gt;5 mA\u003c\/strong\u003e for rapid, stable resistance measurements.\u003c\/li\u003e\n\u003cli\u003eRamp Test Mode: Linearly increase test voltage to pinpoint faults.\u003c\/li\u003e\n\u003cli\u003eBuilt-in timer for controlled testing up to \u003cstrong\u003e99 minutes\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eExtensive data management: Store and review results or transfer data via PC software.\u003c\/li\u003e\n\u003cli\u003eVisual and audio continuity indicators for efficient troubleshooting.\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong\u003e1,300 tests\u003c\/strong\u003e at 2500 V or \u003cstrong\u003e6,500 tests\u003c\/strong\u003e at 250 V on a single charge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1537 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003e8 AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003ePC Software for Data Management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e73.5 mm x 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e8 AA alkaline cells, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e184 mm x 211 mm x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e≤80 % RH (10 °C to 30 °C), ≤50 % RH (30 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 2000 m; Storage: 12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529 IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInsulation Resistance Testing:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Voltage\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003eUp to 500 GΩ\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Measurement:\u003c\/strong\u003e 1 nA to 2 mA, ±20% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Measurement:\u003c\/strong\u003e 0.01 μF to 2.00 μF, ±15% accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarning Range for Energized Circuits:\u003c\/strong\u003e \u0026gt;30 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e \u0026gt;5 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimer Range:\u003c\/strong\u003e 0 to 99 minutes, adjustable in 1-minute intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC Voltage Measurement:\u003c\/strong\u003e Up to 600 V (±2% accuracy).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Measurement:\u003c\/strong\u003e Up to 60.00 kΩ (±2% accuracy).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":42997986525396,"sku":"FK 1537\/APAC","price":12474.3,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/c5147250aa6919262a4524145085778f.jpg?v=1769185352"},{"product_id":"fluke-922-kit-airflow-meter-kit","title":"Fluke 922\/Kit Airflow Meter Kit | Differential Pressure Air Velocity HVAC Tester","description":"\u003ch2 dir=\"ltr\"\u003e\u003cstrong\u003eFluke 922 Airflow Meter Kit — Differential Pressure | Air Velocity | Airflow Volume | HVAC\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eThe \u003cstrong\u003eFluke 922 Airflow Meter\u003c\/strong\u003e is a professional HVAC diagnostic instrument designed to accurately measure airflow, air velocity and differential pressure in ventilation and air-conditioning systems. Widely used by HVAC technicians and facility engineers, the Fluke 922 simplifies troubleshooting of air balance, duct performance and pressure-related issues. The kit version includes essential accessories for comprehensive field testing — suitable for commissioning, maintenance and energy efficiency inspections.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003col\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003e3-in-1 Measurement — Pressure, Velocity \u0026amp; Airflow\u003c\/strong\u003e\u003cbr\u003eMeasures differential pressure, air velocity and airflow volume in a single instrument — replacing multiple tools and simplifying HVAC diagnostic work.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eDuct Traversal for Accurate Airflow\u003c\/strong\u003e\u003cbr\u003ePerforms duct traversals for precise average airflow readings across the full duct cross-section — essential for commissioning and air balancing.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eWide ±4000 Pa Differential Pressure Range\u003c\/strong\u003e\u003cbr\u003eMeasures both positive and negative pressure relationships up to ±4000 Pa — suitable for monitoring indoor\/outdoor pressure differentials, filter conditions and fan performance.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003e99 Reading Data Storage\u003c\/strong\u003e\u003cbr\u003eStores up to 99 readings for convenient on-site data capture and post-inspection analysis.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eIP40 Rugged Design\u003c\/strong\u003e\u003cbr\u003eIP40-rated housing provides protection against dust and solid particles — built for demanding HVAC field environments.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003e280-Hour Battery Life\u003c\/strong\u003e\u003cbr\u003ePowered by four AA batteries with up to 280 hours of operation (backlight off) — minimising battery changes during extended commissioning or maintenance campaigns.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eCE \u0026amp; C-tick Certified\u003c\/strong\u003e\u003cbr\u003eConforms to EU directives (CE) and Australian standards (C-tick N10140) — meeting recognised international safety and quality compliance requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Pressure\u003c\/td\u003e\n\u003ctd\u003e±4000 Pascals\u003c\/td\u003e\n\u003ctd\u003e1 Pascal\u003c\/td\u003e\n\u003ctd\u003e±1% + 1 Pascal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Velocity\u003c\/td\u003e\n\u003ctd\u003e250 to 16,000 fpm\u003c\/td\u003e\n\u003ctd\u003e1 fpm\u003c\/td\u003e\n\u003ctd\u003e±2.5% of reading at 2000 fpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Flow (Volume)\u003c\/td\u003e\n\u003ctd\u003e0 to 99,999 cfm\u003c\/td\u003e\n\u003ctd\u003e1 cfm\u003c\/td\u003e\n\u003ctd\u003eAccuracy depends on velocity and duct size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003ctd\u003e±1% + 2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C (+32°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C (-40°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pressure at Each Port\u003c\/td\u003e\n\u003ctd\u003e10 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage Capacity\u003c\/td\u003e\n\u003ctd\u003e99 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eFour AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e280 hours (without backlight), 60 hours (with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 dir=\"ltr\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eFluke 922 Airflow Meter x1\u003c\/li\u003e\n\u003cli\u003eHoses x2 — 1 black and 1 yellow with test lead strap\u003c\/li\u003e\n\u003cli\u003eHolster x1\u003c\/li\u003e\n\u003cli\u003eWrist Strap x1\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case x1\u003c\/li\u003e\n\u003cli\u003e4 x AA 1.5V Alkaline Batteries (installed)\u003c\/li\u003e\n\u003cli\u003eUser Manual x1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003eApplications\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eHVAC system commissioning and air balancing\u003c\/li\u003e\n\u003cli\u003eDuct airflow and velocity measurement\u003c\/li\u003e\n\u003cli\u003eFilter differential pressure monitoring\u003c\/li\u003e\n\u003cli\u003eBuilding pressure relationship testing\u003c\/li\u003e\n\u003cli\u003eEnergy efficiency inspection and reporting\u003c\/li\u003e\n\u003cli\u003eVentilation system maintenance diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003eWhy Choose Fluke 922 Airflow Meter Kit?\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e3-in-1 pressure, velocity and volume measurement\u003c\/li\u003e\n\u003cli\u003eWide ±4000 Pa differential pressure range\u003c\/li\u003e\n\u003cli\u003eDuct traversal for accurate average airflow\u003c\/li\u003e\n\u003cli\u003e99 reading data storage for field records\u003c\/li\u003e\n\u003cli\u003e280 hour battery life for extended field use\u003c\/li\u003e\n\u003cli\u003eHard carrying case included for protection and transport\u003c\/li\u003e\n\u003cli\u003eCE and C-tick certified for international compliance\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch2\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":42998055076052,"sku":"FK 922\/KIT","price":7474.3,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Fluke_922_kit_01.png?v=1787296663"},{"product_id":"fluke-378-true-rms-clamp-meter","title":"Fluke 378 True-RMS AC\/DC Clamp Meter With iFlex","description":"\u003cstyle\u003e\n\/* Scoped styles for the product description *\/\n.product-description {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n}\n.product-description .highlight {\n    color: #6633ff;\n    font-weight: bold;\n}\n.product-description .offer {\n    color: #e74c3c;\n    font-weight: bold;\n}\n.product-description table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n}\n.product-description table, \n.product-description th, \n.product-description td {\n    border: 1px solid #ddd;\n}\n.product-description th, \n.product-description td {\n    padding: 8px;\n    text-align: left;\n}\n.product-description th {\n    background-color: #f4f4f4;\n}\n.product-description .section-title {\n    color: #333;\n    margin-top: 20px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 378 Non-Contact Voltage True-RMS AC\/DC Clamp Meter with iFlex\u003c\/h1\u003e\n\u003ch2 data-end=\"665\" data-start=\"613\"\u003e\u003cstrong data-end=\"663\" data-start=\"617\"\u003eOverview of Fluke 378 True-RMS Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1192\" data-start=\"666\"\u003eThe \u003cstrong data-end=\"715\" data-start=\"670\"\u003eFluke 378 True-RMS Clamp Meter with iFlex\u003c\/strong\u003e is a professional-grade electrical testing instrument designed for electricians and maintenance technicians. It provides accurate AC\/DC current and voltage measurements while offering True-RMS accuracy for precise readings in complex electrical systems. The included flexible \u003cstrong data-end=\"1016\" data-start=\"992\"\u003eiFlex® current probe\u003c\/strong\u003e allows measurement in tight spaces or around large conductors, making the \u003cstrong data-end=\"1125\" data-start=\"1091\"\u003eFluke 378 True-RMS Clamp Meter\u003c\/strong\u003e ideal for industrial, commercial, and residential troubleshooting.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense™ technology for non-contact voltage and current measurements.\u003c\/li\u003e\n\u003cli\u003ePower Quality (PQ) indicator to identify power supply or equipment issues.\u003c\/li\u003e\n\u003cli\u003eIncludes iFlex® flexible current probe for measuring AC currents up to 2500 A.\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC voltage and current measurements for non-linear signals.\u003c\/li\u003e\n\u003cli\u003eMeasures DC current, voltage, resistance, capacitance, and frequency.\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V safety rating for enhanced protection.\u003c\/li\u003e\n\u003cli\u003eBright green visual continuity screen for easy identification in noisy environments.\u003c\/li\u003e\n\u003cli\u003eThree-phase voltage and current measurement capability with calculated phase values.\u003c\/li\u003e\n\u003cli\u003eCompact and durable design with an ergonomic grip and backlit dual display.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAccuracy Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current via Jaw\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits) (45-66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current via iFlex®\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e1 A (≤2500 A) \/ 0.1 A (≤999.9 A)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 digits) (5-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(2% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (FieldSense)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 digits) (45-66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e60.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω - 10 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.1 μF - 1 μF\u003c\/td\u003e\n\u003ctd\u003e±(1% + 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e274 x 86 x 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e463 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFluke 375 vs 376 vs 378 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-375-true-rms-clamp-meter\"\u003eFluke 375\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-376-true-rms-clamp-meter\"\u003eFluke 376\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 378 (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC current via jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC current via iFlex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2500 A (optional iFlex probe)\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eiFlex i2500-18 probe in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldSense non-contact voltage and PQ indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest leads in the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003ctd\u003eTL224 with TP175 probes and AC285 clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC current to 600 A in a 1000 V meter\u003c\/td\u003e\n\u003ctd\u003eLarger conductors and awkward busbars with iFlex\u003c\/td\u003e\n\u003ctd\u003eVoltage and current without test leads, plus power quality hints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in USA\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000076992724,"sku":"FK 378","price":7659.8,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/cefefabd0932178e605d28a16c576b88.jpg?v=1769186173"},{"product_id":"fluke-1503-insulation-resistance-tester","title":"Fluke 1503 Insulation Resistance Tester 1000V | CAT IV 600V 2000MΩ Earth Bond","description":"\u003cstyle\u003e \/* Scoped styles for the product description *\/ .product-description { font-family: Arial, sans-serif; line-height: 1.6; } .product-description .highlight { color: #6633ff; font-weight: bold; } .product-description .offer { color: #e74c3c; font-weight: bold; } .product-description table { width: 100%; border-collapse: collapse; margin: 20px 0; } .product-description table, .product-description th, .product-description td { border: 1px solid #ddd; } .product-description th, .product-description td { padding: 8px; text-align: left; } .product-description th { background-color: #f4f4f4; } .product-description .section-title { color: #333; margin-top: 20px; } \u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1 dir=\"ltr\"\u003e\u003cstrong\u003eFluke 1503 Insulation Resistance Tester — 1000V | 2000MΩ | CAT IV 600V | Earth Bond\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFluke 1503 Insulation Resistance Tester\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a reliable, easy-to-use insulation tester designed for electricians, maintenance engineers and electrical contractors. Supporting test voltages of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e500V and 1000V\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with insulation resistance measurement up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2000MΩ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the Fluke 1503 is ideal for testing motors, cables, switchgear and \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003einstallations to \u003c\/span\u003e\u003cspan\u003eensure system safety \u003c\/span\u003e\u003cspan\u003eand compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eFluke 1503 Insulation Resistance Meter x1\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eTL224 Test Leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eTP74 Test Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips — Red (PN 1958654) \u0026amp; Black (PN 1958646)\u003c\/li\u003e\n\u003cli\u003eRemote Test Probe\u003c\/li\u003e\n\u003cli\u003eProtective Holster\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003eFour AA Alkaline Batteries (NEDA 15A \/ IEC LR6)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ch2 dir=\"ltr\"\u003eAC\/DC Voltage Measurement\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (50Hz to 400Hz) ±(% of Rdg + Digits)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3MΩ (nominal), \u0026lt;100pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection Ratio (1kΩ unbalanced)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60dB at DC, 50 or 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eEarth Bond Resistance Measurement\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eRange\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20.00Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0Ω\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000Ω\u003c\/td\u003e\n\u003ctd\u003e1.0Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Circuit Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;4.0V, \u0026lt;8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;200.0mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eInsulation Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01MΩ to 2000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+20%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Discharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDischarge time \u0026lt;0.5 second for C = 1μF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLive Circuit Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInhibit test if terminal voltage \u0026gt;30V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Capacitive Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperable with up to 1μF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cstrong\u003eMeasure Accuracy:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTest Voltage\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e500V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5%+5) to 2000MΩ; ±(10%+3) above 2000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eGeneral Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage at Any Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt;18°C or \u0026gt;28°C (\u0026lt;64°F or \u0026gt;82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRandom, 2g, 5-500Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 metre drop per IEC 61010-1 2nd Edition — 6 sides, oak floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectromagnetic Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIn RF field of 3V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TÜV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (H x W x L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 x 10.0 x 20.3cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-Range Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cstrong\u003eAltitude:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000m CAT IV 600V \/ 3000m CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Operating (Storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eUsage\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Test Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt least 1000 insulation tests with fresh alkaline batteries at room temperature. Standard tests of 1000V into 1MΩ with duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. Standard tests of 1Ω with duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 dir=\"ltr\"\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003col\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003e500V \u0026amp; 1000V Test Voltages — 0.01MΩ to 2000MΩ Range\u003c\/strong\u003e\u003cbr\u003eTwo selectable test voltages with insulation resistance measurement up to 2000MΩ cover motor, cable, switchgear and electrical installation testing requirements.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eEarth Bond Continuity — \u0026gt;200mA Short Circuit Current\u003c\/strong\u003e\u003cbr\u003eEarth bond continuity with \u0026gt;200.0mA short circuit current across four resistance ranges supports low-resistance earth bond testing for electrical safety compliance.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eAuto-Discharge in Under 0.5 Seconds\u003c\/strong\u003e\u003cbr\u003eAutomatically discharges capacitive voltage after insulation testing in under 0.5 seconds for capacitive loads up to 1μF — protecting operators from residual voltage hazards.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eLive Circuit Indicator — Test Inhibit Above 30V\u003c\/strong\u003e\u003cbr\u003eAutomatically inhibits insulation testing if terminal voltage exceeds 30V before test initialisation — preventing accidental testing on energised circuits.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eRemote Test Probe\u003c\/strong\u003e\u003cbr\u003eIncluded remote test probe simplifies repetitive insulation testing — trigger tests from the probe end for faster field workflows.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003eCAT IV 600V Safety — CSA \u0026amp; TÜV Certified\u003c\/strong\u003e\u003cbr\u003eComplies with ANSI\/ISA 82.02.01, CAN\/CSA-C22.2 No. 61010-1-04 and IEC\/EN 61010-1 CAT IV 600V, certified by both CSA and TÜV.\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cstrong\u003e1000+ Insulation Test Battery Life\u003c\/strong\u003e\u003cbr\u003eFour AA alkaline batteries support at least 1000 insulation tests and 2500 earth bond measurements per set.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 dir=\"ltr\"\u003eApplications\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMotor insulation resistance testing\u003c\/li\u003e\n\u003cli\u003eCable and wiring insulation verification\u003c\/li\u003e\n\u003cli\u003eSwitchgear and distribution board testing\u003c\/li\u003e\n\u003cli\u003eElectrical installation commissioning\u003c\/li\u003e\n\u003cli\u003eEarth bond continuity verification\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance insulation surveys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003eWhy Choose Fluke 1503?\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e500V and 1000V test voltages for flexible insulation testing\u003c\/li\u003e\n\u003cli\u003eWide 0.01MΩ to 2000MΩ insulation resistance range\u003c\/li\u003e\n\u003cli\u003eEarth bond \u0026gt;200mA short circuit current\u003c\/li\u003e\n\u003cli\u003eAuto-discharge \u0026lt;0.5 seconds for post-test safety\u003c\/li\u003e\n\u003cli\u003eLive circuit inhibit protection above 30V\u003c\/li\u003e\n\u003cli\u003eCAT IV 600V — CSA and TÜV certified\u003c\/li\u003e\n\u003cli\u003e1000+ insulation tests per battery set\u003c\/li\u003e\n\u003cli\u003eTrusted Fluke professional instrument quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000092819668,"sku":"FK 1503","price":5400.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke_1503_01.jpg?v=1788336673"},{"product_id":"fluke-1507-insulation-tester-1","title":"Fluke 1507 Insulation Resistance Tester | 50V to 1000V","description":"\u003cstyle\u003e\n    \/* Scoped styles for the product description *\/\n    .product-description {\n        font-family: Arial, sans-serif;\n        line-height: 1.6;\n    }\n\n    .product-description .highlight {\n        color: #6633ff;\n        font-weight: bold;\n    }\n\n    .product-description .offer {\n        color: #e74c3c;\n        font-weight: bold;\n    }\n\n    .product-description table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 20px 0;\n    }\n\n    .product-description table,\n    .product-description th,\n    .product-description td {\n        border: 1px solid #ddd;\n    }\n\n    .product-description th,\n    .product-description td {\n        padding: 8px;\n        text-align: left;\n    }\n\n    .product-description th {\n        background-color: #f4f4f4;\n    }\n\n    .product-description .section-title {\n        color: #333;\n        margin-top: 20px;\n    }\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 1507 Insulation Resistance Tester\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 1507 Insulation Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 1507 Insulation Tester\u003c\/strong\u003e is a compact and reliable insulation resistance tester designed for professional electricians and maintenance technicians. It supports insulation testing voltages from 50V to 1000V, making it suitable for verifying insulation integrity in motors, cables, panels, and electrical installations. The \u003cstrong\u003eFLUKE 1507 Insulation Tester\u003c\/strong\u003e also integrates essential multimeter functions, allowing users to perform voltage, resistance, and continuity tests using a single handheld instrument.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation resistance tests from \u003cstrong\u003e0.01 MΩ to 10 GΩ\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages: \u003cstrong\u003e50 V, 100 V, 250 V, 500 V, and 1000 V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003elive circuit detection\u003c\/strong\u003e to prevent tests if voltage \u0026gt;30 V is present.\u003c\/li\u003e\n\u003cli\u003eAuto-discharge feature enhances user safety.\u003c\/li\u003e\n\u003cli\u003eMeasures \u003cstrong\u003eAC\/DC voltage\u003c\/strong\u003e from 0.1 V to 600 V.\u003c\/li\u003e\n\u003cli\u003eLow-ohm \u003cstrong\u003eearth-bond continuity\u003c\/strong\u003e (200 mA short circuit current).\u003c\/li\u003e\n\u003cli\u003eRemote test probe simplifies repetitive or hard-to-reach testing.\u003c\/li\u003e\n\u003cli\u003eAuto power-off to extend battery life.\u003c\/li\u003e\n\u003cli\u003eLarge, backlit display for easy readability.\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V overvoltage safety rating.\u003c\/li\u003e\n\u003cli\u003eCompatible with the optional \u003cstrong\u003eFluke TPAK magnetic hanging system\u003c\/strong\u003e for hands-free use.\u003c\/li\u003e\n\u003cli\u003eRuns on four AA alkaline batteries for up to \u003cstrong\u003e1000 insulation tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eTL224 Test Leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eTP74 Test Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003eRemote Test Probe\u003c\/li\u003e\n\u003cli\u003eProtective Holster\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003eFour AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAC\/DC Voltage Measurement:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e0.1 V to 600 V\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz to 400 Hz\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEarth Bond Resistance:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 Ω\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInsulation Resistance:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Voltage\u003c\/th\u003e\n\u003cth\u003eMeasurement Range\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts), ±(10% + 3 above 2000 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eFour AA Alkaline Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 insulation tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e20.3 x 10.0 x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000098783444,"sku":"FK 1507","price":6174.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/FLUKE_1507.png?v=1769186269"},{"product_id":"fluke-1587-insulation-multimeter","title":"Fluke 1587 Insulation Multimeter | 50V–1000V, CAT IV 600V","description":"\u003ch2\u003eFluke 1587 FC Insulation Multimeter 50V–1000V Digital CAT IV 600V \/ CAT III 1000V\u003c\/h2\u003e\n\u003ch2\u003eOverview of Fluke 1587 Insulation Tester\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1587\u003c\/strong\u003e (current version: \u003cstrong\u003eFluke 1587 FC\u003c\/strong\u003e, model FLK-1587-FC) is a professional-grade 2-in-1 digital insulation tester and True-RMS multimeter designed for industrial electrical maintenance, troubleshooting, and preventive testing.\u003c\/p\u003e\n\u003cp\u003eWith selectable test voltages from \u003cstrong\u003e50V to 1000V\u003c\/strong\u003e, a CAT IV 600V \/ CAT III 1000V safety rating, and rugged field-ready construction, this tester is suitable for motors, transformers, switchgear, cables, and industrial systems.\u003c\/p\u003e\n\u003cp\u003eBuilt to withstand harsh environments, it operates from \u003cstrong\u003e-20°C to 55°C\u003c\/strong\u003e, making it ideal for both indoor and site applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features of Fluke 1587 Insulation Tester\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable insulation test voltage: \u003cstrong\u003e50V, 100V, 250V, 500V and 1000V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInsulation resistance range: \u003cstrong\u003e0.01MΩ to 2GΩ\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital display for clear reading\u003c\/li\u003e\n\u003cli\u003eTest current: \u003cstrong\u003e1mA\u003c\/strong\u003e nominal\u003c\/li\u003e\n\u003cli\u003eAuto-discharge of capacitive voltage and live-circuit detection (test inhibited above 30V)\u003c\/li\u003e\n\u003cli\u003eSafety rating: \u003cstrong\u003eCAT IV 600V \/ CAT III 1000V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCSA \u0026amp; CE approved\u003c\/li\u003e\n\u003cli\u003eLong battery life: \u003cstrong\u003eup to 1000 hours\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePowered by 4 × AA batteries\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range (-20°C to 55°C)\u003c\/li\u003e\n\u003cli\u003eCompact \u0026amp; lightweight industrial design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Datasheet of Fluke 1587 Insulation Tester\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFluke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e1587 FC (FLK-1587-FC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInsulation Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester Type\u003c\/td\u003e\n\u003ctd\u003eInsulation Multimeter (insulation tester + True-RMS digital multimeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Test Voltage\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e50V, 100V, 250V, 500V, 1000V (accuracy +20% \/ -0%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Range\u003c\/td\u003e\n\u003ctd\u003e0.01MΩ to 2GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts) at 50V\/100V; ±(1.5% + 5 counts) at 250V\/500V\/1000V up to 600MΩ; ±(10% + 3 counts) for 0.6–2.0GΩ at 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5s for capacitance ≤ 1µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e600.0mV to 1000V True-RMS, with low-pass filter for VFDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e6.000V to 1000V, ±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Millivolts\u003c\/td\u003e\n\u003ctd\u003e600.0mV, ±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC \/ DC Current\u003c\/td\u003e\n\u003ctd\u003e60mA and 400mA ranges; AC ±(1.5% + 2), DC ±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e600.0Ω to 50.0MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000nF to 9999µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e99.99Hz to 99.99kHz, ±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 537°C (K-type thermocouple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test \/ Continuity\u003c\/td\u003e\n\u003ctd\u003eYes \/ audible tone below 25Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category Level\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 (Pollution Degree 2), IEC 61010-2-033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards \/ Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40 (non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e4 × AA (IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e1000 hours meter use, or at least 1000 insulation tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temp\u003c\/td\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temp\u003c\/td\u003e\n\u003ctd\u003e55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing: up to 95% (10–30°C), 75% (30–40°C), 40% (40–55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e203mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e50mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Fluke 1587 FC Insulation Multimeter\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eK-type thermocouple\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 1577 vs 1587 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-1577-insulation-multimeter\"\u003eFluke 1577\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 1587 (this model)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation test voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V\u003c\/td\u003e\n\u003ctd\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation resistance range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ to 600 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes (Type K thermocouple included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance, frequency and diode test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin\/Max recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-pass filter for motor drives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectricians who need 500\/1000 V insulation tests plus a multimeter\u003c\/td\u003e\n\u003ctd\u003eMotor, drive and panel maintenance needing low test voltages and extra functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tpak-magnetic-hanger\"\u003eFluke TPAK magnetic meter hanger\u003c\/a\u003e – hangs the meter on a panel door or steel surface for hands-free readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e💡 Why Choose Fluke 1587?\u003c\/h2\u003e\n\u003ch3\u003e1️⃣ Industrial Safety Compliance\u003c\/h3\u003e\n\u003cp\u003eCAT IV 600V \/ CAT III 1000V safety rating ensures safe operation in high-energy environments.\u003c\/p\u003e\n\u003ch3\u003e2️⃣ Wide Voltage Flexibility\u003c\/h3\u003e\n\u003cp\u003eTest insulation from 50V to 1000V — suitable for low-voltage controls up to industrial equipment.\u003c\/p\u003e\n\u003ch3\u003e3️⃣ Long Battery Performance\u003c\/h3\u003e\n\u003cp\u003eUp to 1000 hours battery life reduces downtime and maintenance interruptions.\u003c\/p\u003e\n\u003ch3\u003e4️⃣ Built for Tough Conditions\u003c\/h3\u003e\n\u003cp\u003eOperates from -20°C to 55°C — suitable for factory floors and outdoor sites.\u003c\/p\u003e\n\u003ch3\u003e5️⃣ Compact Yet Durable\u003c\/h3\u003e\n\u003cp\u003eWeighing only 550g with compact dimensions for easy field portability.\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000107303124,"sku":"FK 1587","price":7402.1,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/FK1587.png?v=1769186294"},{"product_id":"fluke-289-true-rms-digital-multimeter-solo-and-combo-kit","title":"Fluke 289 True-RMS Data Logging Multimeter | 50,000 Counts CAT IV 600V — Solo \u0026 Combo Kit","description":"\u003cstyle\u003e\n\/* Scoped styles for the product description *\/\n.product-description {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n}\n.product-description .highlight {\n    color: #6633ff;\n    font-weight: bold;\n}\n.product-description .offer {\n    color: #e74c3c;\n    font-weight: bold;\n}\n.product-description table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n}\n.product-description table, \n.product-description th, \n.product-description td {\n    border: 1px solid #ddd;\n}\n.product-description th, \n.product-description td {\n    padding: 8px;\n    text-align: left;\n}\n.product-description th {\n    background-color: #f4f4f4;\n}\n.product-description .section-title {\n    color: #333;\n    margin-top: 20px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eFluke 289 True-RMS Data Logging Multimeter — 50,000 Counts | TrendCapture | Made in USA\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThe \u003cstrong\u003eFluke 289 True-RMS Data Logging Multimeter\u003c\/strong\u003e is an advanced professional-grade instrument designed for high-accuracy measurements and on-board data logging. With True-RMS readings for AC and DC voltage and current, a high-resolution \u003cstrong\u003e50,000 count display\u003c\/strong\u003e, and TrendCapture data logging for up to 10,000 events, the Fluke 289 is ideal for industrial, commercial and research applications where precision, reliability and long-term data capture are essential.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eAvailable in two options — the \u003cstrong\u003estandalone Fluke 289 Multimeter\u003c\/strong\u003e or the comprehensive \u003cstrong\u003eFluke 289\/FVF (FlukeView Forms Combo Kit)\u003c\/strong\u003e with software, accessories and carrying case.\u003c\/p\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eWhat's Included\u003c\/h2\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eOption 1 — Fluke 289 Multimeter (Solo)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 289 True-RMS Multimeter\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eTest leads\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e6 AA alkaline batteries (installed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eOption 2 — Fluke 289\/FVF (FlukeView Forms Combo Kit)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 289 True-RMS Multimeter\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFlukeView Forms Software with cable\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eAC175 Alligator Clips\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e80BK-A Thermocouple Probe\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eTL71 Silicon Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\u003ca href=\"\/ms\/products\/fluke-tpak-magnetic-hanger\"\u003eTPAK Magnetic Hanging Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eC280 Soft Case\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eAmp Jack Plug Set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eAccuracy Specifications\u003c\/h2\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\" dir=\"ltr\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eRange\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eResolution\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1000V\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1μV\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±0.025%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1000V\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1μV\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10A\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.01μA\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eAC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10A\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.01μA\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e500MΩ\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.1Ω\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e100mF\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1nF\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e999.99kHz\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.01Hz\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eGeneral Specifications\u003c\/h2\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\" dir=\"ltr\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFluke 289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e50,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-20°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0–90% (0–37°C), 0–65% (37–45°C), 0–45% (45–55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e6 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e~100 hours \/ ~200 hours in logging mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e22.2 x 10.2 x 6cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e870.9g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIEC\/EN 61010-1 3rd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMade in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003col\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eTrue-RMS AC Voltage \u0026amp; Current\u003c\/strong\u003e\u003cbr\u003eAccurate True-RMS measurements on non-linear signals, variable frequency drives and distorted waveforms common in industrial environments.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eAdvanced TrendCapture Data Logging\u003c\/strong\u003e\u003cbr\u003eOn-board TrendCapture records up to 10,000 events with adjustable thresholds for recording and auto-hold events — enabling comprehensive long-term diagnostics.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eHigh-Resolution 50,000 Count Display\u003c\/strong\u003e\u003cbr\u003e50,000 count display delivers exceptional measurement resolution for detailed, precision diagnostics across all measurement functions.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eWide Measurement Range\u003c\/strong\u003e\u003cbr\u003eMeasures up to 1000V AC\/DC, 10A (20A for 30 seconds), 500MΩ resistance, 100mF capacitance and frequency up to 1MHz in a single instrument.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eTrend Graph Mode\u003c\/strong\u003e\u003cbr\u003eBuilt-in trend graph mode visualises measurement changes over time directly on the display — identifying intermittent faults and gradual system changes.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eSelectable AC \u0026amp; Low-Pass Filter\u003c\/strong\u003e\u003cbr\u003eSelectable filters improve measurement accuracy in electrically noisy industrial environments, particularly on VFD\/VSD outputs.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eFlukeView Forms Software (Combo Kit)\u003c\/strong\u003e\u003cbr\u003eFlukeView Forms software with cable allows logged data to be transferred, analysed and compiled into professional reports on a PC.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eTPAK Magnetic Hanging Kit (Combo Kit)\u003c\/strong\u003e\u003cbr\u003eToolPak magnetic strap attaches the meter to any ferrous surface — freeing both hands for safer, more efficient operation.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\n\u003cstrong\u003eMade in USA\u003c\/strong\u003e\u003cbr\u003eAssembled in the USA for the highest standard of build quality and long-term reliability.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eCompatible Accessories\u003c\/h2\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eTest Leads, Probes \u0026amp; Clips\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TLK289 Industrial Master Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL71 Premium Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eFluke TL224 SureGrip Insulated Test Leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL238 SureGrip Test Lead Set for High Energy Environments\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\u003ca href=\"\/ms\/products\/fluke-tl175-twistguard%E2%84%A2-test-leads-set\"\u003eFluke TL175 TwistGuard Test Leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL175-HV CAT III 1500V TwistGuard Test Leads\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL220 SureGrip Industrial Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL223 SureGrip Electrical Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eFluke TL75 Hard Point Test Lead Set\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL81A Deluxe Electronic Test Lead Kit\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL28A Automotive Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL26A 60in 5-Way Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL40 Retractable Tip Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL76 2mm\/4mm Test Lead Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke AC220 SureGrip Alligator Clips\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke AC280 SureGrip Hook Clips\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke AC283 SureGrip Pincer Clips\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke AC285 SureGrip Alligator Clips\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke AC87 Heavy Duty Bus Bar Clip Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke AC89 Heavy Duty Insulation Piercing Test Clip\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TLK-225 SureGrip Master Accessory Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TLK-220 US SureGrip Industrial Test Lead\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke L215 SureGrip Kit with Probe Light and Probe Extenders\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL221 SureGrip Test Lead Extenders\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL940 Mini-Hook Test Leads\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL950 Mini-Pincer Test Leads\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL960 Micro-Hook Test Leads\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL970 Hook and Pincer Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke FTPL-1 Fused Test Probe Set with Test Leads\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke H900 Test Lead Holder\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TP1 \/ TP2 \/ TP4 \/ TP38 Slim Reach Test Probes\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TP80 \/ TP910 \/ TP912 Electronic Test Probes\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TP220 SureGrip Industrial Test Probes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eCurrent Clamps \u0026amp; Probes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke i410 AC\/DC Current Clamp\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke i1010 AC\/DC Current Clamp\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke i200 AC Current Clamp\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke i400 AC Current Clamp\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke i2000 Flex AC Current Clamp\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80K-15 High Voltage Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eAdapters \u0026amp; Cables\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke IR189USB USB Cable Adapter\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke FVF-SC2 FlukeView Forms Software with Cable\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80AK-A Thermocouple Adapter\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke PV350 Pressure Vacuum Module\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TL930 \/ TL932 \/ TL935 Patch Cords\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke TP920 Test Probe Adapter Set\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke FOM Fiber Optic Meter\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke ir3000 FC Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eTemperature Probes \u0026amp; Thermometers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80BK-A Integrated DMM Temperature Probe\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80PK-1 Bead Probe\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80PK-26 SureGrip Tapered Temperature Probe\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80T-150UA Universal Temperature Probe\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80PK-EXT Extension Wire Kit\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80TK Thermocouple Module\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 80K-40 High Voltage Probe\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke 85RF High Frequency Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eCases \u0026amp; Holsters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke C280 Soft Case\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke C116 Soft Carrying Case\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke C781 Meter Case\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke C550 Tool Bag\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke C37XT Protective EVA Hard Tool Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eLights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke L200 Probe Light\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke LVD1A Non-Contact Voltage Tester with LED Flashlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFluke FVF-SC2 FlukeView Forms Software with Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIndustrial electrical maintenance and troubleshooting\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eVFD\/VSD motor drive diagnostics\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePower distribution and power quality analysis\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eLong-term data logging and trend monitoring\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCommercial and research precision measurement\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eField data capture with FlukeView Forms reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eWhy Choose Fluke 289?\u003c\/h2\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eTrue-RMS for accurate non-linear load measurements\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e50,000 count display for high-resolution readings\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eTrendCapture data logging up to 10,000 events\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eWide measurement range covering all key parameters\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eSelectable filters for noisy industrial environments\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFlukeView Forms combo kit for PC data analysis and reporting\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eMade in USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Fluke 289 Multimeter (Solo)","offer_id":48366627717332,"sku":"FK 289","price":6322.0,"currency_code":"MYR","in_stock":true},{"title":"Fluke 289\/FVF (FlukeView Forms Combo Kit)","offer_id":48366627750100,"sku":"FK 289\/FVF","price":7360.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/Fluke_289_FVF_00.jpg?v=1785138231"},{"product_id":"fluke-fev300-ev-test-adapter","title":"Fluke FEV300 EV Charger Test Adapter | Type 1 \u0026 Type 2 Kit","description":"\u003ch1\u003eFLUKE FEV300 EV Test Adapter\u003c\/h1\u003e\n\u003ch2 data-end=\"800\" data-start=\"750\"\u003e\u003cstrong data-end=\"798\" data-start=\"754\"\u003eOverview of FLUKE FEV300 EV Test Adapter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1384\" data-start=\"801\"\u003eThe \u003cstrong data-end=\"837\" data-start=\"805\"\u003eFLUKE FEV300 EV Test Adapter\u003c\/strong\u003e is a professional testing solution designed for verifying the safety and functionality of electric vehicle charging stations. Compatible with both Type 1 and Type 2 connectors, this adapter kit enables technicians to perform accurate testing on EVSE installations during commissioning, maintenance, and inspection. The \u003cstrong data-end=\"1189\" data-start=\"1157\"\u003eFLUKE FEV300 EV Test Adapter\u003c\/strong\u003e allows safe simulation of charging conditions, making it an essential tool for electricians, engineers, and EV infrastructure service providers working in commercial and industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cvideo controls=\"controls\" height=\"auto\" width=\"100%\"\u003e\n\u003csource src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/f7dbfb5c7e714b76a615b5a6711d629d.mp4\" type=\"video\/mp4\"\u003e\n  Your browser does not support the video tag.\u003c\/source\u003e\u003c\/video\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Compatibility:\u003c\/strong\u003e Equipped with both FEV300-CON-TY1 Type 1 Plug for North American stations and FEV300-CON-TY2 Type 2 Plug for European stations, offering versatile testing capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimulates EV Presence:\u003c\/strong\u003e The adapter mimics an electric vehicle, initiating a charging cycle to activate voltage and current output for comprehensive testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Testing Options:\u003c\/strong\u003e Conduct a wide range of tests including ground fault checks, insulation integrity, voltage measurement, and duty cycle analysis to determine the maximum current available for charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Simulation:\u003c\/strong\u003e Allows simulation of Control Pilot (CP) and PE (Earth Fault) errors, essential for troubleshooting and ensuring station functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Indication:\u003c\/strong\u003e Features three LED lamps for clear phase indication, making it easy to check for the presence of voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety and Standards Compliance:\u003c\/strong\u003e Designed to test in accordance with IEC\/EN 61851-1 and IEC\/HD 60364-7-722 standards, ensuring your charging stations meet stringent safety requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable and Robust:\u003c\/strong\u003e Comes with a soft carrying case for easy transport and storage, protecting your investment against the rigors of fieldwork.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-specs\"\u003e\n\u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFEV300\/TY1 \u0026amp; TY2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eType 1 (SAE J1772) \u0026amp; Type 2 (IEC 62196) Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eEV Charging Stations with Type 1 or Type 2 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 80 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test\u003c\/td\u003e\n\u003ctd\u003eYes, for checking insulation integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError Simulation\u003c\/td\u003e\n\u003ctd\u003eControl Pilot (CP) and Proximity Pilot (PP) errors, Earth Fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Indication\u003c\/td\u003e\n\u003ctd\u003e3 LED phase indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61851-1, IEC\/HD 60364-7-722\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +40°C (32°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (-4°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with Case)\u003c\/td\u003e\n\u003ctd\u003e2.0kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003eSoft carrying case, user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43764661420244,"sku":"FK FEV300\/TY1 \u0026 TY2","price":9113.5,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/20240417035750b4e9dfe9054d3b700d5fabe95a92df37.png?v=1773245204"},{"product_id":"fluke-287-digital-multimeter","title":"Fluke 287 True-RMS Logging Multimeter | 50,000 Count 1000V","description":"\u003cstyle\u003e\n\/* Scoped styles for the product description *\/\n.product-description {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n}\n.product-description .highlight {\n    color: #6633ff;\n    font-weight: bold;\n}\n.product-description .offer {\n    color: #e74c3c;\n    font-weight: bold;\n}\n.product-description table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n}\n.product-description table, \n.product-description th, \n.product-description td {\n    border: 1px solid #ddd;\n}\n.product-description th, \n.product-description td {\n    padding: 8px;\n    text-align: left;\n}\n.product-description th {\n    background-color: #f4f4f4;\n}\n.product-description .section-title {\n    color: #333;\n    margin-top: 20px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 1AC II Non-Contact Voltage Tester\u003c\/h1\u003e\n\u003ch2 data-end=\"793\" data-start=\"743\"\u003e\u003cstrong data-end=\"791\" data-start=\"747\"\u003eOverview of FLUKE 287 Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1424\" data-start=\"794\"\u003eThe \u003cstrong data-end=\"830\" data-start=\"798\"\u003eFLUKE 287 Digital Multimeter\u003c\/strong\u003e is a professional True-RMS handheld meter designed for advanced electrical troubleshooting and diagnostics. It supports measurements up to 1000V AC and DC, with a maximum current capacity of 10A for both AC and DC applications. Built for electricians, engineers, and industrial technicians, the \u003cstrong data-end=\"1158\" data-start=\"1126\"\u003eFLUKE 287 Digital Multimeter\u003c\/strong\u003e combines accuracy, data logging capability, and robust safety ratings to handle complex electrical environments. Its large display and advanced functions make it suitable for in-depth analysis of electrical systems in industrial, commercial, and field applications.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDetects voltage from 90 V to 1000 V AC.\u003c\/li\u003e\n\u003cli\u003eVisual and audible indicators for voltage presence.\u003c\/li\u003e\n\u003cli\u003eCAT IV 1000 V safety rating for maximum protection.\u003c\/li\u003e\n\u003cli\u003eContinuous self-test ensures reliable operation.\u003c\/li\u003e\n\u003cli\u003eCompact and portable design with batteries included.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAccuracy Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principle\u003c\/td\u003e\n\u003ctd\u003eSenses steady-state electrostatic field produced by AC voltage through insulation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Detection Range\u003c\/td\u003e\n\u003ctd\u003e90 V AC to 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Tip Style\u003c\/td\u003e\n\u003ctd\u003eFlat-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: CAT IV 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% (0°C to 30°C); 0% to 75% (30°C to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e2 AAA alkaline batteries (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 year (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e150 mm x 19 mm x 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":44038616252628,"sku":"FK 287","price":5632.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Screenshot2023-10-27at3.38.41PM.png?v=1773245261"},{"product_id":"fluke-1630-2-earth-tester","title":"Fluke 1630-2 Earth Ground Clamp | Stakeless Earth Tester 1.5kΩ","description":"\u003cdiv\u003e\n\u003cdiv class=\"sc-htoDjs dvYSZg\"\u003e\n\u003cdiv id=\"accordion-product-details-body\" aria-labelledby=\"accordion-product-details-title\" data-testid=\"accordion-product-details-body\"\u003e\n\u003csection class=\"[\u0026amp;_a]:text-blue-500 hover:[\u0026amp;_a]:text-blue-700 [\u0026amp;_ul]:list-disc [\u0026amp;_ul]:p-4\" data-testid=\"descriptive-content-container\"\u003e\n\u003cdiv class=\"sc-htoDjs dvYSZg\"\u003e\n\u003ch1 data-start=\"865\" data-end=\"912\"\u003e\u003cstrong data-start=\"869\" data-end=\"910\"\u003eFLUKE 1630-2 Earth Tester\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"865\" data-end=\"912\"\u003e\u003cstrong data-start=\"869\" data-end=\"910\"\u003eOverview of FLUKE 1630-2 Earth Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"913\" data-end=\"1528\"\u003eThe \u003cstrong data-start=\"917\" data-end=\"946\"\u003eFLUKE 1630-2 Earth Tester\u003c\/strong\u003e is a professional electrical instrument designed to accurately measure earth (ground) resistance up to 1.5kΩ. Built for industrial, commercial, and field applications, it ensures reliable grounding verification for safety and compliance. The tester supports CAT III 1000V and CAT IV 600V safety ratings, providing maximum protection during measurements. Its compact, ergonomic design allows easy handling, and the \u003cstrong data-start=\"1361\" data-end=\"1390\"\u003eFLUKE 1630-2 Earth Tester\u003c\/strong\u003e delivers precise readings even in challenging environments, making it an essential tool for electricians and maintenance professionals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3 class=\"font-oswald text-lg font-bold\" data-testid=\"descriptive-content-main-header\"\u003e\u003cstrong\u003eFeatures \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003e• Large memory capable of storing more than 32,000 measurements\u003cbr\u003e• Band-pass filter removes noise, for accurate AC leakage current detection\u003cbr\u003e• Easy-to-read LCD screen means you can see data in most light conditions\u003cbr\u003e• IP30-rated when its jaw is closed so protected against tools and wires larger than 2.5mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3 class=\"font-oswald text-lg font-bold\" data-testid=\"descriptive-content-main-header\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003e• Electrical installation\u003cbr\u003e• Safety systems\u003cbr\u003e• Construction industry\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch3 class=\"font-oswald text-lg font-bold\" data-testid=\"descriptive-content-main-header\"\u003e\u003cstrong\u003eHow heavy is this earth tester?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"sc-hEsumM ilIvoT\"\u003eWith a light weight of just 880g, this tool is easy to handle and carry with you on the job.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"sc-htoDjs dvYSZg\"\u003e\u003chr class=\"my-10 border-t border-mono-200\"\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"sc-htoDjs dvYSZg\"\u003e\n\u003cdiv id=\"accordion-specifications-body\" aria-labelledby=\"accordion-specifications-title\" data-testid=\"accordion-specifications-body\"\u003e\n\u003csection\u003e\n\u003cdiv class=\"sc-htoDjs dvYSZg\"\u003e\n\u003ch2 class=\"mb-4 font-oswald text-2xl font-bold\" data-testid=\"specifications-heading-title\"\u003eSpecifications\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003ctable class=\"w-full border-separate border-spacing-0 text-normal table-auto\" data-testid=\"specification-attributes\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003cth class=\"h-11 py-0 font-bold leading-snug border-b-2 border-mono-100 px-4 bg-red-highlight text-white text-left\"\u003e\n\u003cdiv class=\"line-clamp-2 w-full\"\u003eAttribute\u003c\/div\u003e\n\u003c\/th\u003e\n\u003cth class=\"h-11 py-0 font-bold leading-snug border-b-2 border-mono-100 px-4 bg-red-highlight text-white text-left\"\u003e\n\u003cdiv class=\"line-clamp-2 w-full\"\u003eValue\u003c\/div\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"text-sm\"\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eAbsolute Maximum Resistance Measurement\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e1.5kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eBest Accuracy\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e±1.5 % of 0.02 Reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003eEarth Ground Loop Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003eCAT III 1000 V, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e15 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003eAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003ePower Source\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003eBattery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e283 x 105 x 48mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e880g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e283mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eIncludes\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e4 AA Batteries, Earth Ground Clamp, Hard Case, Loop Resistance Standard, Quick Reference Guide, Safety Information Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eLength\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e105mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e+50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e48mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eSafety Category Level\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003eCAT III, CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eModel Number p\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e1630-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eSafety Category Voltage\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e600 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd:bg-white even:bg-mono-50\"\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-key\"\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd class=\"border-b border-mono-100 bg-inherit px-4 py-2 text-left\" data-testid=\"specification-attributes-value\"\u003e-10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":44231278166228,"sku":"FK 1630-2","price":16500.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Screenshot2024-01-04at2.00.36AM.png?v=1773245320"},{"product_id":"fluke-381-clamp-meter","title":"Fluke 381 True-RMS AC\/DC Clamp Meter | iFlex \u0026 Remote Display","description":"\u003cstyle\u003e\n\/* Scoped styles for the product description *\/\n.product-description {\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n}\n.product-description .highlight {\n    color: #6633ff;\n    font-weight: bold;\n}\n.product-description .offer {\n    color: #e74c3c;\n    font-weight: bold;\n}\n.product-description table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n}\n.product-description table, \n.product-description th, \n.product-description td {\n    border: 1px solid #ddd;\n}\n.product-description th, \n.product-description td {\n    padding: 8px;\n    text-align: left;\n}\n.product-description th {\n    background-color: #f4f4f4;\n}\n.product-description .section-title {\n    color: #333;\n    margin-top: 20px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eFluke 381 Remote Display True RMS AC\/DC Clamp Meter with iFlex®\u003c\/h1\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch2 data-end=\"905\" data-start=\"862\"\u003e\u003cstrong data-end=\"903\" data-start=\"866\"\u003eOverview of Fluke 381 Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1431\" data-start=\"906\"\u003eThe \u003cstrong data-end=\"935\" data-start=\"910\"\u003eFluke 381 Clamp Meter\u003c\/strong\u003e is a professional-grade AC\/DC testing tool featuring a remote display and iFlex® flexible current probe. It provides accurate True RMS measurements for AC\/DC current, voltage, resistance, and continuity. The iFlex® probe allows flexible access to tight spaces, making it ideal for industrial, commercial, and field applications. With its ergonomic and robust design, the \u003cstrong data-end=\"1332\" data-start=\"1307\"\u003eFluke 381 Clamp Meter\u003c\/strong\u003e delivers precise readings while enhancing user convenience and safety in electrical diagnostics.\u003c\/p\u003e\n\u003ch2\u003eOther key features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eErgonomic design fits in your hand and can be used while wearing protective equipment\u003c\/li\u003e\n\u003cli\u003eRadio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Conformance\u003c\/strong\u003e: IEC\/EN 61010-1:2001, 1000V CAT III, 600V CAT IV\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 381 Remote Display True RMS AC\/DC Clamp Meter with iFlex®\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ± 5 digits (10-100 Hz)\u003cbr\u003e5% ± 5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3 @ 500 A\u003cbr\u003e2.5 @ 600 A\u003cbr\u003e1.42 @ 1000 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A \/ 2500 A (45 Hz – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3.0 at 1100 A\u003cbr\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003cimg alt=\"Flexible current probe\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDistance from Optimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ei2500-10 Flex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ei2500-18 Flex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eError\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600 V \/1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.5% ± 5 digits (20 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 V \/1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eFrequency – Via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5.0 – 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 – 10 Hz, ≥ 10 A\u003cbr\u003e10 – 100 Hz, ≥ 5 A\u003cbr\u003e100 – 500 Hz, ≥ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eFrequency via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5.0 to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 to 20 Hz, ≥ 25 A\u003cbr\u003e20 to 100 Hz, ≥ 20 A\u003cbr\u003e100 to 500 Hz, ≥ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600 Ω\/6 kΩ\/60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Ω\/1 Ω\/10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e277 x 88 x 43 mm (55 mm for remote unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e350 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Cable Length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eNon condensing (\u0026lt; 10°C)\u003cbr\u003e≤ 90% RH (at 10°C to 30°C)\u003cbr\u003e≤ 75% RH (at 30°C to 40°C)\u003cbr\u003e≤ 45% RH (at 40°C to 50°C)\u003cbr\u003e(Without Condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI, RFI, EMC, RF\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEN 61326-1:2006, EN 61326-2-2:2006\u003cbr\u003eETSI EN 300 328 V1.7.1:2006\u003cbr\u003eETSI EN 300 489 V1.8.1:2008\u003cbr\u003eFCC Part 15 Subpart C Sections 15.207, 15.209, 15.249\u003cbr\u003eFCCID: T68-F381\u003cbr\u003eRSS-210 IC: 6627A-F381\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAdd 0.1 x specified accuracy for each degree C above 28°C or below 18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.4 GHz ISM Band 10 meter range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eANSI\/ISA S82.02.01:2004\u003cbr\u003eCAN\/CSA-C22.2 No. 61010-1-04\u003cbr\u003eIEC\/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble Insulation Clearance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePer IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble Insulation Creepage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePer IEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd class=\"certifications\" colspan=\"4\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePackage Includes Fluke 381 Clamp Meter:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e18-inch iFlex\u003csup\u003e®\u003c\/sup\u003eflexible current probe\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl75-test-lead-set\"\u003eTL75 test leads\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eFive AA Alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2800\" data-start=\"2758\"\u003e\u003cstrong data-end=\"2798\" data-start=\"2762\"\u003eWhy Choose Fluke 381 Clamp Meter \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"3160\" data-start=\"2801\"\u003eThe \u003cstrong data-end=\"2830\" data-start=\"2805\"\u003eFluke 381 Clamp Meter\u003c\/strong\u003e is perfect for professionals needing accurate AC\/DC current measurement in challenging or confined spaces. Its True RMS accuracy, remote display, and iFlex® probe make it versatile for field, industrial, and commercial electrical diagnostics. This clamp meter ensures reliability, convenience, and precision in one robust tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":44414562959572,"sku":"FK 381","price":7490.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Fluke_381_01.jpg?v=1773245345"},{"product_id":"fluke-787-processmeter-loop-calibrator-multimeter","title":"Fluke 787 ProcessMeter, Loop Calibrator \u0026 Digital Multimeter 1000V, 20 mA DC, True-RMS","description":"\u003ch1 data-end=\"1222\" data-start=\"846\"\u003eFluke 787 ProcessMeter, Loop Calibrator \u0026amp; Multimeter 1000V, 20 mA DC, True-RMS\u003c\/h1\u003e\n\u003ch2 data-end=\"768\" data-start=\"727\"\u003e\u003cstrong data-end=\"768\" data-start=\"730\"\u003eOverview of Fluke 787 ProcessMeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1303\" data-start=\"769\"\u003eThe \u003cstrong data-end=\"799\" data-start=\"773\"\u003eFluke 787 ProcessMeter\u003c\/strong\u003e is a professional-grade instrument that combines a True-RMS digital multimeter with a 4–20 mA loop calibrator in one rugged device. Designed for industrial and process control environments, the Fluke 787 ProcessMeter allows technicians to measure voltage up to 1000V while sourcing, simulating, and measuring DC current signals accurately. Its compact design and reliable performance make the Fluke 787 ProcessMeter an essential tool for calibration, troubleshooting, and maintenance of control systems.\u003c\/p\u003e\n\u003ch2 data-end=\"1705\" data-start=\"1684\"\u003e✨ \u003cstrong data-end=\"1705\" data-start=\"1689\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2159\" data-start=\"1706\"\u003e\n\u003cli data-end=\"1763\" data-start=\"1706\"\u003e\n\u003cp data-end=\"1763\" data-start=\"1708\"\u003eCombines a loop calibrator and multimeter in one unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1820\" data-start=\"1764\"\u003e\n\u003cp data-end=\"1820\" data-start=\"1766\"\u003eSource, simulate, and measure 20 mA DC current loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1868\" data-start=\"1821\"\u003e\n\u003cp data-end=\"1868\" data-start=\"1823\"\u003eTrue RMS AC voltage and current measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1928\" data-start=\"1869\"\u003e\n\u003cp data-end=\"1928\" data-start=\"1871\"\u003eLarge, backlit display for easy visibility in low light\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1989\" data-start=\"1929\"\u003e\n\u003cp data-end=\"1989\" data-start=\"1931\"\u003e1000 V overload protection on volts, ohms, and frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2049\" data-start=\"1990\"\u003e\n\u003cp data-end=\"2049\" data-start=\"1992\"\u003eIncludes auto-step and auto-ramp features for mA output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2097\" data-start=\"2050\"\u003e\n\u003cp data-end=\"2097\" data-start=\"2052\"\u003eDurable, compact, and easy to carry on-site\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2159\" data-start=\"2098\"\u003e\n\u003cp data-end=\"2159\" data-start=\"2100\"\u003eCompatible with Fluke ToolPak™ magnetic hanger (optional)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ Specification\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eCurrent measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.05% + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent sourcing\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-20 mA or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.05% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Capability\u003c\/td\u003e\n\u003ctd\u003e500 Ω @ 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTo 19.999 kHz, 0.005% + 1 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBeeps for resistance \u0026lt; 100 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1000 V AC or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% Rdg + 1 LSD (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTo 40 MΩ, 0.2% + 1 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 V shows diode voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e95% up to 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e75% up to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e45% up to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e35% up to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C (for temperatures \u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDesigned in accordance with IEC 1010-1, ANSI\/ISA S82.01-1994 and CAN\/CSA C22.2 No. 1010.1-92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 1010-1 CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32 x 87 x 187 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e369 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSingle 9 V Alkaline battery (ANSI\/NEDA 1604A or IEC 6LR61)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 hours typical (measurement), 12 hours typical (sourcing 12 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eShock and vibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 meter drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay current and % of span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto step, auto ramp\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":46349067550932,"sku":"FK 787","price":9300.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Fluke_787_01.jpg?v=1773245540"},{"product_id":"fluke-vt08-visual-ir-thermometer-thermal-imaging-camera-400-c","title":"Fluke VT08 Visual IR Thermometer | -20°C to 400°C","description":"\u003ch2\u003eFluke VT08 Visual IR thermometer\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch2 data-end=\"764\" data-start=\"713\"\u003e\u003cstrong data-end=\"764\" data-start=\"716\"\u003eOverview of Fluke VT08 Visual IR Thermometer\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1315\" data-start=\"765\"\u003eThe \u003cstrong data-end=\"805\" data-start=\"769\"\u003eFluke VT08 Visual IR Thermometer\u003c\/strong\u003e is a compact thermal imaging camera designed to help professionals quickly locate temperature anomalies and potential faults. Combining infrared temperature measurement with visual thermal mapping, the Fluke VT08 Visual IR Thermometer enables fast diagnostics for electrical, mechanical, and building maintenance applications. With a temperature range up to 400°C and a 120 × 90 pixel detector resolution, this tool provides clear thermal images that simplify troubleshooting and preventive maintenance tasks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003e120 x 90 resolution for more details\u003c\/li\u003e\n\u003cli\u003eWide temperature range, -20 °C to 400 °C\u003c\/li\u003e\n\u003cli\u003eBlends a visual image with infrared heat image overlay in real-time to clearly distinguish the measured target\u003c\/li\u003e\n\u003cli\u003eIP65 rated for dust and water proof, 2m drop test, suitable for harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eQuickly locate the measured target with built-in laser pointer\u003c\/li\u003e\n\u003cli\u003e2 hours charging time, 5 hours battery life\u003c\/li\u003e\n\u003cli\u003eSingle-level menu interface, Open-and-View\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd width=\"33%\"\u003eThermal image and optics\u003c\/td\u003e\n\u003ctd width=\"33%\"\u003eVT08\u003c\/td\u003e\n\u003ctd width=\"33%\"\u003eVT06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e120×90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR frequency band\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7.5~14 μm(long wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal sensitivity\/NETD\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;60 mk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view (H x V)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50° x 37.5°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpatial resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7.6 mrad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus system\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFocus free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum focusing distance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 m (19.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVisible light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisible resolution\u003c\/td\u003e\n\u003ctd\u003e320×240\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisible FOV (H x V)\u003c\/td\u003e\n\u003ctd\u003e53° x 41°\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eImage display and storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage mode\u003c\/td\u003e\n\u003ctd\u003eThermal image\u003cbr\u003eVisible image\u003cbr\u003ePIP\u003c\/td\u003e\n\u003ctd\u003eThermal image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePalettes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIronbow, Blue-Red, High-Contrast, Amber, Hot Metal, Grayscale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal storage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;28GB (\u0026gt;100000 images)\u003cbr\u003e*14GB Internal Storage for VT06\/VT08 manufactured before 6 Aug 2022.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFile format\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eJPEG compression format (.jpg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePIP mode\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTemperature measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 °C to 400 °C\u003cbr\u003e[-4 °F to 752 °F] (not specified for below -10 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±2°C or 2% @ 23°C±5°C, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackground temperature compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto high-\/low-temperature capture\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCenter point temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum\/minimum temperature alarm in full screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInterface and lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisible lens\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlashlight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared lens\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser sighting\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType-C interface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTF card slot\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripod interface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile App\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePower system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRechargeable Li-ion battery, unremovable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery operation time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≥5 hrs (VT08)\u003cbr\u003e≥8 hrs (VT06)\u003cbr\u003eActual battery life depends on environment and settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;2.5 hrs to full\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 °C to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging system\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCharge in the machine (the battery is not removable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC adapter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInclude power supply, universal adapter\u003cbr\u003eOutput: 5 VDC, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower saving mode\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m (1.24 mi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12 000 m (7.5 mi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOthers\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eStandard accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWrist strap, quick reference guide, charger + adapter, Type-C data cable, data-downloading card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.096 cm (2.4-inch) LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20.4 cm x 6.6 cm x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60825-1: Class 2, 650 nm, \u0026lt;1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 62133-2, UN 38.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP65 (with Type-C port closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Industrial Electromagnetic Environment\u003cbr\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003ePackage Includes:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVT08 Visual IR Thermometer\u003c\/li\u003e\n\u003cli\u003eWrist strap \u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eCharger + Adapter \u003c\/li\u003e\n\u003cli\u003eTYPE-C data cable \u003c\/li\u003e\n\u003cli\u003eData-downloading card \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2237\" data-start=\"2207\"\u003e\u003cstrong data-end=\"2237\" data-start=\"2210\"\u003eWhy Choose This Product Fluke VT08 Visual IR Thermometer\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"2561\" data-start=\"2238\"\u003eThe Fluke VT08 Visual IR Thermometer offers an efficient way to detect overheating components before failures occur. Its thermal imaging capability, compact design, and ease of use make it an excellent choice for technicians seeking fast, reliable temperature diagnostics without the complexity of high-end thermal cameras.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":46453514666196,"sku":"FK VT08\/APC","price":5790.2,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Fluke_vt08_02.webp?v=1773245542"},{"product_id":"fluke-1577-insulation-multimeter","title":"Fluke 1577 Insulation Multimeter | 1000V True-RMS","description":"\u003ch1 class=\"features-title\"\u003eFluke 1577 Insulation Multimeter\u003c\/h1\u003e\n\u003ch2 data-end=\"764\" data-start=\"713\"\u003e\u003cstrong data-end=\"764\" data-start=\"716\"\u003eOverview of Fluke 1577 Insulation Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1313\" data-start=\"765\"\u003eThe \u003cstrong data-end=\"805\" data-start=\"769\"\u003eFluke 1577 Insulation Multimeter\u003c\/strong\u003e is a professional-grade testing instrument designed for insulation resistance testing and advanced electrical troubleshooting. Combining insulation testing up to 1000V with True-RMS multimeter functionality, the Fluke 1577 Insulation Multimeter allows technicians to measure voltage, resistance, continuity, and insulation safely and accurately. Its rugged design and clear digital display make it suitable for industrial, commercial, and maintenance environments where reliability and safety are essential.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli data-end=\"1774\" data-start=\"1712\"\u003e\n\u003cp data-end=\"1774\" data-start=\"1714\"\u003eCombines \u003cstrong data-end=\"1772\" data-start=\"1723\"\u003e1000V insulation tester + true RMS multimeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1847\" data-start=\"1775\"\u003e\n\u003cp data-end=\"1847\" data-start=\"1777\"\u003e\u003cstrong data-end=\"1808\" data-start=\"1777\"\u003eTest voltages: 500V \/ 1000V\u003c\/strong\u003e with insulation range up to \u003cstrong data-end=\"1845\" data-start=\"1837\"\u003e600MΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1915\" data-start=\"1848\"\u003e\n\u003cp data-end=\"1915\" data-start=\"1850\"\u003eMeasures \u003cstrong data-end=\"1913\" data-start=\"1859\"\u003eAC\/DC voltage, resistance, continuity, and current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1981\" data-start=\"1916\"\u003e\n\u003cp data-end=\"1981\" data-start=\"1918\"\u003eTrue RMS accuracy for non-linear loads and noisy environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2049\" data-start=\"1982\"\u003e\n\u003cp data-end=\"2049\" data-start=\"1984\"\u003eIncludes \u003cstrong data-end=\"2014\" data-start=\"1993\"\u003eremote test probe\u003c\/strong\u003e for easy one-handed measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2103\" data-start=\"2050\"\u003e\n\u003cp data-end=\"2103\" data-start=\"2052\"\u003e\u003cstrong data-end=\"2077\" data-start=\"2052\"\u003eLarge backlit display\u003c\/strong\u003e for improved visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2157\" data-start=\"2104\"\u003e\n\u003cp data-end=\"2157\" data-start=\"2106\"\u003eAuto power off, data hold, low battery indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2225\" data-start=\"2158\"\u003e\n\u003cp data-end=\"2225\" data-start=\"2160\"\u003eRugged Fluke build quality, \u003cstrong data-end=\"2225\" data-start=\"2188\"\u003eCAT III 1000V \/ CAT IV 600V rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(2.0%+2)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum test current @ 1kΩ\/V\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMaximum resistance per test voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e600 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMaximum resolution per test voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eAccuracy per test voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% - 95% (10°C – 30°C)\u003cbr\u003e0% - 75% (30°C – 40°C)\u003cbr\u003e0% - 40% (40°C – 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-033: CAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e203 x 100 x 50 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e624 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life alkaline\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeter use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation test use\u003c\/td\u003e\n\u003ctd\u003eMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eFluke 1577 vs 1587 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eFluke 1577 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-1587-insulation-multimeter\"\u003eFluke 1587\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation test voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V\u003c\/td\u003e\n\u003ctd\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation resistance range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ to 600 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ to 2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes (Type K thermocouple included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance, frequency and diode test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin\/Max recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-pass filter for motor drives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectricians who need 500\/1000 V insulation tests plus a multimeter\u003c\/td\u003e\n\u003ctd\u003eMotor, drive and panel maintenance needing low test voltages and extra functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tpak-magnetic-hanger\"\u003eFluke TPAK magnetic meter hanger\u003c\/a\u003e – hangs the meter on a panel door or steel surface for hands-free readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eFour AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eCD rom with manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":46620330918100,"sku":"FK 1577","price":6399.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Fluke_1577_01.png?v=1773245553"},{"product_id":"fluke-789-processmeter","title":"Fluke 789 ProcessMeter Digital Multimeter \u0026 Loop Calibrator","description":"\u003ch2 data-end=\"636\" data-start=\"612\"\u003eFluke 789 ProcessMeter™ Overview Summary\u003c\/h2\u003e\n\u003ch2 data-end=\"808\" data-start=\"767\"\u003e\u003cstrong data-end=\"808\" data-start=\"770\"\u003eOverview of Fluke 789 ProcessMeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1307\" data-start=\"809\"\u003eThe \u003cstrong data-end=\"839\" data-start=\"813\"\u003eFluke 789 ProcessMeter\u003c\/strong\u003e is an all-in-one digital multimeter and loop calibrator designed for precise measurement of voltage, current, and resistance, while also performing 4–20 mA loop calibration. Its robust construction and clear display provide reliable readings in industrial, commercial, and maintenance environments. The Fluke 789 ProcessMeter is ideal for electricians, process technicians, and engineers who need both multimeter functionality and loop calibration in a single device.\u003c\/p\u003e\n\u003ch2 data-end=\"1193\" data-start=\"1173\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-end=\"2093\" data-start=\"1194\"\u003e\n\u003cli data-end=\"1302\" data-start=\"1194\"\u003e\n\u003cp data-end=\"1302\" data-start=\"1196\"\u003eTrue-RMS digital multimeter and loop calibrator in one instrument. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1403\" data-start=\"1303\"\u003e\n\u003cp data-end=\"1403\" data-start=\"1305\"\u003eBuilt-in 24 V loop supply for offline transmitter testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1517\" data-start=\"1404\"\u003e\n\u003cp data-end=\"1517\" data-start=\"1406\"\u003eSelectable 250 Ω HART®-resistor built-in (no separate resistor needed). \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1635\" data-start=\"1518\"\u003e\n\u003cp data-end=\"1635\" data-start=\"1520\"\u003eDual-display: shows simultaneously mA and % of span for quick verification. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1759\" data-start=\"1636\"\u003e\n\u003cp data-end=\"1759\" data-start=\"1638\"\u003eSource\/measure\/simulate 0-20 mA or 4-20 mA with 1200 Ω drive capability at 20 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1871\" data-start=\"1760\"\u003e\n\u003cp data-end=\"1871\" data-start=\"1762\"\u003eFrequency measurement to 20 kHz, Min\/Max\/Average\/Hold\/Relative modes. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1871\" data-start=\"1760\"\u003e\n\u003cp data-end=\"1871\" data-start=\"1762\"\u003eSafety rated for industrial use: IEC 61010-1, CAT IV 600 V \/ CAT III 1000 V.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2093\" data-start=\"1991\"\u003e\n\u003cp data-end=\"2093\" data-start=\"1993\"\u003eWireless data logging ready (with optional IR3000FC module).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFluke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e789 ProcessMeter™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Multimeter + mA Loop Calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage (DC)\u003c\/td\u003e\n\u003ctd\u003e0-1000 V DC, resolution 0.1 mV-1.0 V, accuracy 0.1% +1 LSD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage (AC True-RMS)\u003c\/td\u003e\n\u003ctd\u003e0-1000 V AC, accuracy 0.7% +2 LSD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Source\/Measure (mA)\u003c\/td\u003e\n\u003ctd\u003e0-20.000 mA or 4-20 mA selectable; 1200 Ω drive at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 V built-in (on 789) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART® Resistor\u003c\/td\u003e\n\u003ctd\u003eBuilt-in selectable 250 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 19.999 kHz, accuracy 0.005% +1 LSD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eUp to 40 MΩ, accuracy 0.2% +1 LSD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003eBeep for \u0026lt; ~100 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20 °C to +55 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd\u003e95% up to 30 °C; 75% up to 40 °C; 45% up to 50 °C; 35% up to 55 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, CAT IV 600 V \/ CAT III 1000 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H×W×L)\u003c\/td\u003e\n\u003ctd\u003e50 × 100 × 203 mm (1.97″ × 3.94″ × 8.00″) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 610 g (1.6 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eFour AA alkaline batteries \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-end=\"4053\" data-start=\"4030\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 data-end=\"4053\" data-start=\"4030\"\u003ePackage Content\u003c\/h2\u003e\n\u003cp data-end=\"4085\" data-start=\"4056\"\u003e1 × Fluke 789 ProcessMeter™\u003c\/p\u003e\n\u003cp data-end=\"4159\" data-start=\"4088\"\u003e1 × Set AC175 Alligator Clips \u003c\/p\u003e\n\u003cp data-end=\"4226\" data-start=\"4162\"\u003e1 × TL71 Test Lead Set\u003c\/p\u003e\n\u003cp data-end=\"4314\" data-start=\"4229\"\u003e4 × AA 1.5 V Alkaline Batteries (installed)\u003c\/p\u003e\n\u003cp data-end=\"4354\" data-start=\"4317\"\u003e1 x Quick Reference Guide \/ User Manual\u003c\/p\u003e\n\u003cp data-end=\"4452\" data-start=\"4357\"\u003e\u003cstrong\u003e** (Optional)\u003c\/strong\u003e IR3000FC Wireless Module — sold separately\u003c\/p\u003e\n\u003cp data-end=\"4452\" data-start=\"4357\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"4714\" data-start=\"4690\"\u003e💡 Why Choose Fluke\u003c\/h2\u003e\n\u003cp data-end=\"5206\" data-start=\"4715\"\u003eFluke is a world-renowned leader in test and measurement instruments, trusted by professionals across industries for reliability, accuracy and durability. The 789 ProcessMeter™ is engineered to help instrumentation and electrical technicians \u003cstrong data-end=\"4988\" data-start=\"4957\"\u003edo more while carrying less\u003c\/strong\u003e, expanding troubleshooting capability with a single tool. With top-end safety ratings, HART® support, built-in loop power, and rugged design, it’s built for the field and for fast, trusted calibration and diagnostics.\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":47246838431956,"sku":null,"price":9400.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/files\/Fluke_789_ProcessMeter_technical_data.png?v=1773245600"}],"url":"https:\/\/techno.my\/ms\/collections\/sata-superdeal-buy-x-copy.oembed","provider":"Techno Tools \u0026 Equipment","version":"1.0","type":"link"}