{"product_id":"fluke-115-true-rms-digital-multimeter","title":"Fluke 115 True-RMS Digital Multimeter | Field Technician's Meter","description":"\u003ch2\u003eFluke 115 Field Technicians Digital Multimeter\u003c\/h2\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview of FLUKE 115 Electrician’s Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLUKE 115 Electrician’s Multimeter\u003c\/strong\u003e is a versatile and reliable tool designed for electricians, technicians, and maintenance professionals. It combines accurate AC\/DC voltage and current measurements with resistance, continuity, diode, capacitance and frequency testing. The Fluke 115 does not have non-contact voltage detection (VoltAlert); that feature is found on the Fluke 117. The compact design and clear digital display make the \u003cstrong\u003eFLUKE 115 Electrician’s Multimeter\u003c\/strong\u003e ideal for residential, commercial, and light industrial applications, ensuring efficient and accurate electrical diagnostics.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTrue-RMS measurements for accurate readings of non-linear loads\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMin\/Max\/Average recording with elapsed time\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompact, lightweight design for one-handed use\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e6000-count resolution with large backlit display and 33-segment bar graph\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCAT III 600V safety rating\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eContinuity and diode test\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCapacitance measurements up to 9999 µF\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFrequency measurements up to 50 kHz\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e9V Alkaline battery with 400 hours typical life\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eFluke 115 Digital Multimeter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHolster with probe holders\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInstalled 9V Battery\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4mm PVC-Insulated Test Leads\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eQuick Reference Guide\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003ch3\u003eAccuracy Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRange \/ Resolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Millivolts\u003c\/td\u003e\n\u003ctd\u003e600.0mV \/ 0.1mV\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Volts\u003c\/td\u003e\n\u003ctd\u003e6.000V \/ 0.001V; 60.00V \/ 0.01V; 600.0V \/ 0.1V\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Millivolts (True RMS)\u003c\/td\u003e\n\u003ctd\u003e600.0mV \/ 0.1mV\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (45Hz to 500Hz); 2.0% + 3 (500Hz to 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Volts (True RMS)\u003c\/td\u003e\n\u003ctd\u003e6.000V \/ 0.001V; 60.00V \/ 0.01V; 600.0V \/ 0.1V\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (45Hz to 500Hz); 2.0% + 3 (500Hz to 1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e600.0Ω \/ 0.1Ω to 40.00MΩ \/ 0.01MΩ\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1; 5% + 2 (40.00MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 1Ω\u003c\/td\u003e\n\u003ctd\u003eBeeper on below 20Ω, off above 250Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e2.000V \/ 0.001V\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000nF \/ 1nF to 9999µF \/ 1µF\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Amps (True RMS)\u003c\/td\u003e\n\u003ctd\u003e6.000A \/ 0.001A; 10.00A \/ 0.01A\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3 (45Hz to 500Hz); 20A overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Amps\u003c\/td\u003e\n\u003ctd\u003e6.000A \/ 0.001A; 10.00A \/ 0.01A\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3; 20A overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e99.99Hz \/ 0.01Hz to 50kHz \/ 0.01kHz\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFLUKE-115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0095969344814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e600V (between any terminal and earth ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600V, Pollution Degree 2 (IEC 61010-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e6kV peak per IEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Contact Voltage\u003c\/td\u003e\n\u003ctd\u003eNo (available on Fluke 117)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 counts, updates 4 times per second; bar graph 33 segments, updates 32 times per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e9V Alkaline (IEC 6LR61)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e167 × 84 × 46mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFluke 113 vs 114 vs 115 vs 116 vs 117 comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-113-digital-multimeter\"\u003eFluke 113\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-114-true-rms-digital-multimeter\"\u003eFluke 114\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 115 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-116-digital-multimeter-100-new-original\"\u003eFluke 116\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-117-electrician-s-multimeter-with-non-contact-voltage\"\u003eFluke 117\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e10 A AC\/DC\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e10 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroamps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600.0 µA AC\/DC\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 400 °C (80BK probe included)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto voltage \/ LoZ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVCHEK (LoZ)\u003c\/td\u003e\n\u003ctd\u003eAutoVolt + LoZ\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eAutoVolt + LoZ\u003c\/td\u003e\n\u003ctd\u003eAutoVolt + LoZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in non-contact voltage (VoltAlert)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9999 µF\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUp to 9999 µF\u003c\/td\u003e\n\u003ctd\u003eUp to 9999 µF\u003c\/td\u003e\n\u003ctd\u003eUp to 9999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 kΩ\u003c\/td\u003e\n\u003ctd\u003e40 MΩ\u003c\/td\u003e\n\u003ctd\u003e40 MΩ\u003c\/td\u003e\n\u003ctd\u003e40 MΩ\u003c\/td\u003e\n\u003ctd\u003e40 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUtility and basic voltage\/continuity checks\u003c\/td\u003e\n\u003ctd\u003eGo\/no-go electrical checks without current\u003c\/td\u003e\n\u003ctd\u003eGeneral field service, with amps\u003c\/td\u003e\n\u003ctd\u003eHVAC: flame sensor µA and temperature\u003c\/td\u003e\n\u003ctd\u003eElectricians: non-contact voltage, LoZ and amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl175-twistguard%E2%84%A2-test-leads-set\"\u003eFluke TL175 TwistGuard test lead set\u003c\/a\u003e – extendable insulated tips for safe probing in CAT III\/CAT IV areas\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eFluke TL224 SureGrip silicone test lead set\u003c\/a\u003e – flexible silicone-insulated leads that stay supple in heat and cold\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-tpak-magnetic-hanger\"\u003eFluke TPAK magnetic meter hanger\u003c\/a\u003e – hangs the meter on a panel door or steel surface for hands-free readings\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-c25-large-soft-case-for-digital-multimeter\"\u003eFluke C25 large soft carrying case\u003c\/a\u003e – padded case for the meter, leads and small accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/ms\/products\/fluke-c35-soft-multimeter-carrying-case\"\u003eFluke C35 soft carrying case\u003c\/a\u003e – zipped soft case for the meter and test leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrigin:\u003c\/h2\u003e\n\u003cp\u003eMade in China\u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43000150884564,"sku":"FK 115","price":1699.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/a7cfbbfdd7ad1a95edf1e74fe5d06588.jpg?v=1769186555","url":"https:\/\/techno.my\/ms\/products\/fluke-115-true-rms-digital-multimeter","provider":"Techno Tools \u0026 Equipment","version":"1.0","type":"link"}