{"product_id":"fluke-116-hvac-multimeter","title":"Fluke 116 True-RMS HVAC Multimeter 600V with Temperature \u0026 Microamps | CAT III 600V","description":"\u003cp\u003eThe Fluke 116 is a True-RMS digital multimeter designed for HVAC technicians. Built-in temperature measurement with the included 80BK probe and a 600µA microamp range for flame sensor testing sit alongside AutoVolt\/LoZ voltage, resistance, continuity, capacitance and frequency, on a backlit 6,000-count display rated CAT III 600V.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in thermometer\u003c\/strong\u003e – -40°C to 400°C with the included 80BK Type K probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroamps\u003c\/strong\u003e – 600.0µA AC\/DC for flame sensor testing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutoVolt \/ LoZ\u003c\/strong\u003e – automatic AC\/DC selection and low impedance to avoid ghost voltage readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e AC voltage\u003c\/li\u003e\n\u003cli\u003eResistance, continuity, diode, capacitance and frequency\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eLarge white LED backlight for poorly lit areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT III 600V\u003c\/strong\u003e safety rating; fits the optional TPAK magnetic hanger\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange \/ Resolution\u003c\/th\u003e\n\u003cth\u003eAccuracy ±(% of reading + counts)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e600.0mV \/ 0.1mV\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e6.000V \/ 60.00V \/ 600.0V\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-V \/ LoZ\u003c\/td\u003e\n\u003ctd\u003e600.0V \/ 0.1V\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC to 500Hz); 4.0% + 3 (500Hz–1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC millivolts (True-RMS)\u003c\/td\u003e\n\u003ctd\u003e600.0mV \/ 0.1mV\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC to 500Hz); 2.0% + 3 (500Hz–1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC volts (True-RMS)\u003c\/td\u003e\n\u003ctd\u003e6.000V \/ 60.00V \/ 600.0V\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC to 500Hz); 2.0% + 3 (500Hz–1kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e600.0Ω to 6.000MΩ\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (high range)\u003c\/td\u003e\n\u003ctd\u003e40.00MΩ \/ 0.01MΩ\u003c\/td\u003e\n\u003ctd\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e600Ω \/ 1Ω\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt;20Ω, off \u0026gt;250Ω; detects opens\/shorts of 500µs or longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e2.000V \/ 0.001V\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000nF to 9999µF\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2 (to 1000µF); 5% + 20 (above 1000µF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoZ capacitance\u003c\/td\u003e\n\u003ctd\u003e1nF to 500µF\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e99.99Hz to 50.00kHz\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (Type K)\u003c\/td\u003e\n\u003ctd\u003e-40°C to 400°C \/ 0.1°C\u003c\/td\u003e\n\u003ctd\u003e1% + 10 (probe error excluded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC microamps (True-RMS, 45–500Hz)\u003c\/td\u003e\n\u003ctd\u003e600.0µA \/ 0.1µA\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC microamps\u003c\/td\u003e\n\u003ctd\u003e600.0µA \/ 0.1µA\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage (any terminal to earth)\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6,000 counts, 4 updates\/sec; 33-segment bar graph, 32 updates\/sec; white LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e9V alkaline (IEC 6LR61), approx. 400 hours typical without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e167 x 84 x 46mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMade in China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 61010-1, Pollution Degree 2\u003c\/li\u003e\n\u003cli\u003eIEC 61010-2-033 CAT III 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Fluke 116 HVAC multimeter\u003c\/li\u003e\n\u003cli\u003e1 × pair of 4mm silicone test leads\u003c\/li\u003e\n\u003cli\u003e1 × 80BK integrated temperature probe\u003c\/li\u003e\n\u003cli\u003e1 × holster\u003c\/li\u003e\n\u003cli\u003e1 × 9V battery (installed)\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional Accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tpak-magnetic-hanger\"\u003eFluke TPAK magnetic meter hanger\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl224-suregrip-silicone-test-leads\"\u003eFluke TL224 SureGrip silicone test lead set\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-tl175-twistguard%E2%84%A2-test-leads-set\"\u003eFluke TL175 TwistGuard test lead set\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-c25-large-soft-case-for-digital-multimeter\"\u003eFluke C25 large soft carrying case\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ms\/products\/fluke-c35-soft-multimeter-carrying-case\"\u003eFluke C35 soft carrying case\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC\/R service: flame sensor microamp checks on furnaces and boilers\u003c\/li\u003e\n\u003cli\u003eSupply and return air, pipe and coil temperature checks\u003c\/li\u003e\n\u003cli\u003eMotor-run and start capacitor testing\u003c\/li\u003e\n\u003cli\u003eGhost-voltage-free control circuit checks with LoZ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFluke 114 vs 115 vs 116 vs 117\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-114-true-rms-digital-multimeter\"\u003eFluke 114\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-115-true-rms-digital-multimeter\"\u003eFluke 115\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003eFluke 116 (this model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/ms\/products\/fluke-117-electrician-s-multimeter-with-non-contact-voltage\"\u003eFluke 117\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e10A AC\/DC\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e10A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroamps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600.0µA AC\/DC\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-V \/ LoZ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltAlert non-contact voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGo\/no-go electrical checks\u003c\/td\u003e\n\u003ctd\u003eGeneral field service with amps\u003c\/td\u003e\n\u003ctd\u003eHVAC: flame sensor µA and temperature\u003c\/td\u003e\n\u003ctd\u003eElectricians: VoltAlert, LoZ and amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":43083594367188,"sku":"FK 116","price":1596.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/7518c4b6c323c53f4f8d763c465f71bd.jpg?v=1770653953","url":"https:\/\/techno.my\/ms\/products\/fluke-116-hvac-multimeter","provider":"Techno Tools \u0026 Equipment","version":"1.0","type":"link"}