Fluke 381 Clamp Meter | True RMS AC/DC with iFlex® Remote Display
Helpful Documents
- Product Brochure Muat turun
- Product Datasheet / User manual Muat turun
Tidak dapat memuatkan ketersediaan pengambilan
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®
Overview of Fluke 381 Clamp Meter
The Fluke 381 Clamp Meter is a professional-grade AC/DC testing tool featuring a remote display and iFlex® flexible current probe. It provides accurate True RMS measurements for AC/DC current, voltage, resistance, and continuity. The iFlex® probe allows flexible access to tight spaces, making it ideal for industrial, commercial, and field applications. With its ergonomic and robust design, the Fluke 381 Clamp Meter delivers precise readings while enhancing user convenience and safety in electrical diagnostics.
Other key features
- Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Three-year warranty
Safety Conformance: IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV
Specifications: Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®
| Electrical Specifications | ||||
| AC Current via Jaw | ||||
| Range | 999.9 A | |||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) |
|||
| Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 |
|||
| AC Current via Flexible Current Probe | ||||
| Range | 999.9 A / 2500 A (45 Hz – 500 Hz) | |||
| Resolution | 0.1 A / 1 A | |||
| Accuracy | 3% ± 5 digits | |||
| Crest Factor (50/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
| Position Sensitivity | ||||
![]() |
Distance from Optimum | |||
| i2500-10 Flex | i2500-18 Flex | Error | ||
| A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ±0.5% | |
| B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ±1.0% | |
| C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ±2.0% | |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
| DC Current | ||||
| Range | 999.9 A | |||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits | |||
| AC Voltage | ||||
| Range | 600 V /1000 V | |||
| Resolution | 0.1 V / 1 V | |||
| Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
| DC Voltage | ||||
| Range | 600.0 V /1000 V | |||
| Resolution | 0.1 V / 1 V | |||
| Accuracy | 1% ± 5 digits | |||
| Frequency – Via Jaw | ||||
| Range | 5.0 – 500.0 Hz | |||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A |
|||
| Frequency via Flexible Current Probe | ||||
| Range | 5.0 to 500.0 Hz | |||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
|||
| Resistance | ||||
| Range | 600 Ω/6 kΩ/60 kΩ | |||
| Resolution | 0.1 Ω/1 Ω/10 Ω | |||
| Accuracy | 1% ± 5 digits | |||
| Mechanical Specifications | ||||
| Size (L x W x H) | 277 x 88 x 43 mm (55 mm for remote unit) | |||
| Weight | 350 g | |||
| Jaw Opening | 34 mm | |||
| Flexible Current Probe Diameter | 7.5 mm | |||
| Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
| Environmental Specifications | ||||
| Operating Temperature | -10°C to +50°C | |||
| Storage Temperature | -40°C to +60°C | |||
| Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) |
|||
| Operating Altitude | 2,000 meters | |||
| Storage Altitude | 12,000 meters | |||
| EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 |
|||
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||
| Wireless Frequency | 2.4 GHz ISM Band 10 meter range | |||
| Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. |
|||
| Double Insulation Clearance | Per IEC 61010-2-032 | |||
| Double Insulation Creepage | Per IEC 61010-1 | |||
| Agency Approvals | ||||
Package Includes Fluke 381 Clamp Meter:
- 18-inch iFlex®flexible current probe
- Coated instruction card
- Safety information sheet
- Soft carrying case
- TL75 test leads
- Five AA Alkaline batteries
Why Choose Fluke 381 Clamp Meter
The Fluke 381 Clamp Meter is perfect for professionals needing accurate AC/DC current measurement in challenging or confined spaces. Its True RMS accuracy, remote display, and iFlex® probe make it versatile for field, industrial, and commercial electrical diagnostics. This clamp meter ensures reliability, convenience, and precision in one robust tool.
Order by 4PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on time.
Free delivery for total orders above RM500, otherwise additional charges costs are calculated at checkout based on your order’s weight and delivery location.
Further details please click here for more info.
Please notify us within 14 calendar days of receiving your product to request a free exchange or full refund, if eligible. We will cover all return shipping costs, and no restocking fees will apply in this case.
Requests made after 14 days may be accepted at our discretion and will be subject to a 10% restocking fee. Techno Tools & Equipment reserves the right to reject any return request found to be ineligible.
Further details please click here for more info.