{"product_id":"kyoritsu-2009r-clamp-meter","title":"KYORITSU 2009R Clamp Meter – Digital KEW 2009R","description":"\u003ch1 class=\"goods_name\"\u003eKEW 2009R AC\/DC Clamp Meter\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ch2 data-start=\"820\" data-end=\"855\"\u003e\u003cstrong data-start=\"823\" data-end=\"853\"\u003eKYORITSU 2009R Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"856\" data-end=\"1279\"\u003eThe \u003cstrong data-start=\"860\" data-end=\"890\"\u003eKYORITSU 2009R Clamp Meter\u003c\/strong\u003e is a precision instrument designed for accurate AC\/DC current measurement. The KEW 2009R features a compact, ergonomic design with a clear digital display and stable readings, ensuring reliable operation. Its portability and performance make the KYORITSU 2009R Clamp Meter ideal for electricians, maintenance technicians, and engineers performing field measurements and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS Instrument:\u003c\/strong\u003e Ensures accurate measurements of distorted waveforms and non-sinusoidal signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Measurement:\u003c\/strong\u003e Handles AC and DC currents up to 2000A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Terminal:\u003c\/strong\u003e Enables recorder connection for efficient data analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Measurements:\u003c\/strong\u003e Supports AC\/DC voltage, resistance, continuity testing, and frequency measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e Offers a minimum resolution of 0.1A for detailed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets IEC 61010-1 CAT IV 600V \/ CAT III 1000V standards for secure operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current (ACA)\u003c\/td\u003e\n\u003ctd\u003e400.0A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±3dgt (0 - 400.0A, 150 - 1700A) [45 - 66Hz]; ±2.0%rdg ±5dgt (20Hz - 1kHz); ±2.3%rdg ±3dgt (1701 - 2000A) [45 - 66Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current (DCA)\u003c\/td\u003e\n\u003ctd\u003e400.0A \/ 2000A\u003c\/td\u003e\n\u003ctd\u003e±1.3%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage (ACV)\u003c\/td\u003e\n\u003ctd\u003e40.00V \/ 400.0V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±3dgt [45 - 66Hz]; ±1.5%rdg ±5dgt [20Hz - 1kHz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage (DCV)\u003c\/td\u003e\n\u003ctd\u003e40.00V \/ 400.0V \/ 1000V\u003c\/td\u003e\n\u003ctd\u003e±1.0%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance (Ω)\u003c\/td\u003e\n\u003ctd\u003e400.0Ω \/ 4000Ω\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±2dgt (Electronic protection up to 600V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBuzzer sounds below 20 ±1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e10.0 - 4000Hz\u003c\/td\u003e\n\u003ctd\u003e±1.5%rdg ±5dgt (Input sensitivity: Current \u0026gt;40A, Voltage \u0026gt;10V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRecorder: DC400mV (against AC\/DC400.0A); DC200mV (against AC\/DC2000A)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\" border=\"1\" cellpadding=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 CAT IV 600V \/ CAT III 1000V, Pollution Degree 2; IEC 61010-031; IEC 61010-2-032; IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e2 × R6 (AA) (1.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm × 105 mm × 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 540g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eTest leads (7107A), carrying case (9094), 2 × R6 (AA) batteries, instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eOutput cord (7256)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cstrong\u003eWarranty: 1 Year\u003c\/strong\u003e\u003c\/div\u003e","brand":"KYORITSU","offers":[{"title":"Default Title","offer_id":43073106510036,"sku":"KE 2009R","price":2216.5,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3038\/9972\/products\/25d375d954227bd8bfe2aa859b8fe55f.jpg?v=1770653829","url":"https:\/\/techno.my\/products\/kyoritsu-2009r-clamp-meter","provider":"Techno Tools \u0026 Equipment","version":"1.0","type":"link"}