KYORITSU 6205 Portable Appliance Tester | KEW 6205
Pickup available at No.36-1, Jalan Sulaiman 1,
Usually ready in 2-4 days
Got questions?
Feel free to WhatsApp us

Ask an expert
KYORITSU 6205 Portable Appliance Tester | KEW 6205
Protect life and property from faulty appliances
- Battery operated
- PASS/FAIL result
- Color status backlight
- 10mA & 30mA RCD test(Isolation transformer built in)
- Memory function up to 999 data
- Printer output
KEW 6205 equipped with Wireless LAN: available only in Australia and New Zealand.
Test Function
Function | Tests of contents |
---|---|
Class Ⅰ Test | • Protective conductor resistance (Test current 200mA DC nominal) • Insulation resistance test (250V or 500V) • Leakage current test (100-253V/50Hz) • Load current test (100-253V/50Hz) |
Class Ⅱ Test | • Insulation resistance test (250V or 500V) • Leakage current test (100-253V/50Hz) • Load current test (100-253V/50Hz) |
Extension Lead Test | • Protective conductor resistance (Test current 200mA DC nominal) • Insulation resistance test (between Line/Neutral-Earth short, Line/Neutral) • Leakage current test (100-253V/50Hz) • Polarity test |
RCD Test | • RCD test (10mA/30mA) |
Mains voltage indication
Display range | 30V-270V |
---|---|
Accuracy | ±5V |
Protective conductor resistance test
Measuring range | 0.00-20.00Ω |
---|---|
Open circuit voltage | 5V±0.4V DC |
Measuring current | 200mA DC(nominal value) |
Accuracy | ±3%rdg±5dgt |
Insulation resistance test
Rated volatge | 250V | 500V |
---|---|---|
Measuring range | 0.00-20.00MΩ | |
No-load voltage | 250V DC +20%,-0% | 500V DC +20%,-0% |
Short circuit current | 1.5mA DC or less | |
Accuracy | ±2%rdg±3dgt |
Load current/Leakage current test
Item | Load current | Leakage current |
---|---|---|
Mains voltage range | 100-253V/50Hz | |
Measuring range | 0.10-10.00A rms | 0.10-20.00mA rms |
Accuracy | ±10%rdg±5dgt | ±3%rdg±5dgt |
RCD test
Rated voltage | 230V -15% - +10%/50Hz | |
---|---|---|
Rated current | 10mA/30mA | |
Function | × 1 | × 5 |
Test duration | 0.0ms-500.0ms | 0.0ms-40.0ms |
Operating time accuracy | ±2ms(≦40ms),±8ms(>40ms) |
General
Power source | LR6(AA)(1.5V) × 6 |
---|---|
Applicable Standards | IEC/EN61010-1 CAT II 300V, IEC/EN61010-2-030, IEC/EN61010-031, EN61326-2-2, AS/NZ3760 |
Dimensions / Weight | 261(L) × 104(W) × 57(D)mm / Approx. 930g(including batteries) |
Included Accessories | 7277(Mains lead), 7129A(Test lead with Alligator clip), 7161A(Flat test prod), 7276(Adaptor for Extension cord), 9193(Carrying case), 8928(Fuse[10A/250V]), 9121(Shoulder strap), Buckle, LR6(AA) x 6, Instruction manual |
Optional Accessories | 8263-USB(USB cable with "KEW Report(software)"), 7275(Printer cable:Mini Din 6pin-D-sub 9pin), 7248(Test lead with Alligator clip and Flat test probe) |
Order by 4PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on time.
Free delivery for total orders above RM500, otherwise additional charges costs are calculated at checkout based on your order’s weight and delivery location.
Further details please click here for more info.
Please notify us within 14 calendar days of receiving your product to request a free exchange or full refund, if eligible. We will cover all return shipping costs, and no restocking fees will apply in this case.
Requests made after 14 days may be accepted at our discretion and will be subject to a 10% restocking fee. Techno Tools & Equipment reserves the right to reject any return request found to be ineligible.
Further details please click here for more info.