Fluke 54 II B Dual Input Data Logging Thermometer | J/K/T/E/N/R/S Thermocouple -200°C to 1767°C
- Product Datasheet (PDF) Muat turun
- User manual / Instruction Book (PDF) Muat turun
Tidak dapat memuatkan ketersediaan pengambilan
The Fluke 54 II B Data Logging Thermometer is a professional dual-input thermocouple thermometer for HVAC, industrial and laboratory work. It reads two thermocouples at once (T1, T2 and T1-T2), supports J, K, T, E, N, R and S types up to 1767°C, and logs up to 500 readings at a user-set interval for download to a PC via the IR-USB port and optional FlukeView Forms software.
Key Features & Benefits
- Dual input: T1, T2, T1-T2 plus MIN, MAX or AVG on a backlit dual display
- Logs up to 500 data points with user-adjustable interval; recall on screen
- J, K, T, E, N, R and S thermocouple types
- Accuracy ±(0.05% + 0.3°C) above -100°C (J, K, T, E, N)
- Relative time clock on MIN, MAX and AVG; electronic offset for probe errors
- Infrared USB port for FlukeView Forms Temperature software (optional)
- Splash- and dust-resistant case with impact-absorbing holster
- 1000-hour typical battery life on 3 x AA; battery door opens without breaking the calibration seal
Technical Specifications
| Specification | Value |
|---|---|
| Inputs | 2 thermocouple inputs |
| Thermocouple ranges | J: -210°C to 1200°C K: -200°C to 1372°C T: -250°C to 400°C E: -150°C to 1000°C N: -200°C to 1300°C R/S: 0°C to 1767°C |
| Accuracy above -100°C | J, K, T, E, N: ±(0.05% + 0.3°C); R, S: ±(0.05% + 0.4°C) |
| Accuracy below -100°C | J, K, E, N: ±(0.20% + 0.3°C); T: ±(0.50% + 0.3°C) |
| Display resolution | 0.1°C / 0.1 K (<1000); 1°C / 1 K (≥1000) |
| Data logging | Up to 500 points, user-adjustable interval |
| PC interface | Infrared USB (FlukeView Forms, optional) |
| Temperature scale / standard | ITS-90 / NIST-175 |
| Power | 3 x AA batteries, 1000 hours typical |
| Operating temperature | -10°C to 50°C |
| Storage temperature | -40°C to 60°C |
| Humidity (non-condensing) | 0% to 90% (0°C to 35°C); 0% to 70% (0°C to 50°C) |
| Dimensions (L x W x D) | 173 x 86 x 38mm |
| Weight | 400g |
| Country of origin | Made in China |
Safety & Compliance
- Overvoltage category per CSA C22.2 No. 1010.1 1992 and EN 61010 Amendments 1, 2
- Agency approvals: CE, CSA, TÜV (pending)
What's in the Box
- Fluke 54 II B thermometer
- Impact-absorbing holster
- 2 x 80PK-1 bead probe thermocouples (type K)
Optional Accessories
- Fluke TPAK ToolPak magnetic meter hanger – magnet or strap mounting for hands-free use
- FlukeView Forms software with cable – sold separately and available on request
- Fluke 80PK-1, 80PK-3A, 80PK-8, 80PK-22, 80PK-24, 80PK-25, 80PK-26 and 80PK-27 temperature probes – available on request
- Fluke 80PK-EXT, 80PJ-EXT, 80PT-EXT extension wire kits; 700TC2 plug kit; 80CK-M / 80CJ-M connectors – available on request
- Fluke C101, C50, C550 and CXT170 cases – available on request
Applications
- HVAC supply/return and differential temperature logging
- Furnace, kiln and heat-treatment checks with R/S/N thermocouples
- Process temperature trending and troubleshooting
- Laboratory and quality-control measurement
Fluke 51 II vs 52 II vs 54 II B comparison
| Specification | Fluke 51 II | Fluke 52 II | Fluke 54 II B (this model) |
|---|---|---|---|
| Thermocouple inputs | 1 | 2 | 2 |
| T1-T2 differential | No | Yes | Yes |
| Thermocouple types | J, K, T, E | J, K, T, E | J, K, T, E, N, R, S |
| Maximum temperature | 1372°C (type K) | 1372°C (type K) | 1767°C (type R/S) |
| Data logging | No | No | Up to 500 points |
| PC connection | No | No | IR-USB to FlukeView Forms (optional) |
| Best for | Single-point spot checks | Two-point and differential readings, e.g. HVAC supply/return | Logging and high-temperature R/S/N thermocouples |
| Warranty period | 3 Year Warranty |
|---|---|
| Coverage | Free from defects in material and workmanship for 3 years from the date of purchase. Accessories supplied with the product, such as test leads and probes, are covered for 1 year from the date of purchase. |
| Not covered | Fuses, disposable batteries and manuals; damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. |
| Warranty void if | The product has been used outside its specifications, altered, or repaired by a party not authorised by Fluke. |
Contact Techno Tools with your proof of purchase. The warranty applies to the original purchaser only.
Order by 4PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on time.
Free delivery for orders above RM500 with a total weight under 22kg. Otherwise, delivery charges are calculated at checkout based on your order’s weight and delivery location.
Further details please click here for more info.
Please notify us within 14 calendar days of receiving your product to request a free exchange or full refund, if eligible. We will cover all return shipping costs, and no restocking fees will apply in this case.
Requests made after 14 days may be accepted at our discretion and will be subject to a 10% restocking fee. Techno Tools & Equipment reserves the right to reject any return request found to be ineligible.
Further details please click here for more info.