FLUKE 1587 Insulation Multimeter 50-1000V

Only 2 left
SKU: FK 1587
Regular price RM6,820.00 MYR
Regular price -11% RM7,691.00 MYR Sale price RM6,820.00 MYR

Product Brochure

Click Here: Brochure in PDF

Product Datasheet / User Manual

Click Here: Datasheet in PDF

Fluke 1587 Insulation Multimeter

  • With the Fluke 1587, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease.
  • Two products in one: Powerful and full-featured multimeter.
  • Ideal for work on motors, cables, and switch gear.
  • Large display with backlight.
  • Filter for motor drive measurements.
  • Insulation test (0.01 MΩ to 2 GΩ).
  • Insulation test voltages (50 V, 100 V, 250 V, 500 V, 1000 V) for many applications.
  • CAT III 1000 V /CAT IV 600 V overvoltage rating for added user protection.
Specifications
Voltage DC Maximum voltage 1000 V
Accuracy ±(0.09% + 2)
Maximum resolution 0.001V
Voltage AC Maximum voltage 1000 V
Accuracy ±(2% + 3)
AC bandwidth 5 kHz1
1. With low pass filter; 3 db @ 800 Hz
Maximum resolution 0.1 mV
Current DC Maximum amps 400 mA
Amps accuracy ±(0.2% + 2)
Maximum Resolution 0.01 mA
Current AC Maximum amps 400 mA
Amps accuracy ±(1.5% + 2) 1
1. 1 kHz bandwidth
Maximum resolution 0.01 mA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.9% + 2)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
Accuracy ±(1.2% + 2)
Maximum resolution 1 nF
Frequency Maximum frequency 100 kHz
Accuracy ±(0.1% + 1)
Maximum resolution 0.01 Hz
Temperature measurement -40.0°C to 537°C
-40.0°F to 998°F
excluding probe
Diode test Range 6 V
Resolution 1 mV
Accuracy ±(2% + 1)
Insulation Test
Minimum test current @ 1 kΩ/V 1 mA
Test voltages 50, 100, 250, 500, 1000 V
Maximum resistance per test voltage 50 V
100 V
250 V
500 V
1000 V 2 GΩ
Maximum resolution per test voltage 50 V 0.01 MΩ
100 V 0.01 MΩ
250 V 0.1 MΩ
500 V 0.1 MΩ
1000 V 0.1 MΩ
Accuracy per test voltage 50 V ±(3% + 5)
100 V ±(3% + 5)
250 V ±(1.5% + 5)
500 V ±(1.5% + 5)
1000 V ±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
Environmental Specifications
Operating temperature –20°C to +55°C
Storage temperature -40°C to +60°C
Humidity (without condensation) 0% - 95% (10°C – 30°C)
0% - 75% (30°C – 40°C)
0% - 40% (40°C – 55°C)
Operating altitude 2000 m
Safety Specifications
Overvoltage category Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency approvals 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical and General Specifications
Size 203 x 100 x 50 mm (with holster)
Weight 624 g
Warranty 3 years
Battery life Alkaline Meter use 1000 hours
Insulation test use Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating IP40