FLUKE 417D Laser Distance Meter (Rangefinder)
Regular price
RM1,011.00 MYR
Couldn't load pickup availability
Got questions?
Feel free to WhatsApp us
Product Brochure
Click Here: Brochure in PDF
Product Datasheet / User Manual
Click Here: Datasheet in PDF
'- The Fluke 417D laser meter is accurate, durable, and easy to use—just point and shoot
- Instantly measure up to 40 m (131 ft.) with 1-button point-and-click
- Continuous measurement capable: adjusting as you move closer and farther from your target
- Quickly calculate area (sq feet/meters)
- 1-meter drop tested and IP54 rated: built to withstand rainy or dusty conditions
- Great for interior and exterior applications
Product overview: Fluke 417D Laser Distance Meter
The Fluke 417D is accurate, durable, and easy to use—just point and shoot. The simple design and easy, one-button measurement operation allows you to minimize time spent measuring and maximize the reliability of measurements.
Additional Product Features:
Large, 2-line illuminated LCD screen.
Three different measurement tasks can be completed quickly and easily with one hand.
The bright laser is clearly visible, so you can always see your target point even from a hard-to-reach spot or long distance.
Designed for both indoor and outdoor applications.
Operates with the Fluke durability and quality you expect.
Protected by a 3-year warranty.
Specifications:
Typical range [1] 0.2-40 m/0.6-131 ft
Typical measuring tolerance* [1] 2.0 mm ± 1.5 mm/± 0.06 in ***
Maximum measuring tolerance [2] ± 3.0 mm/0.12 in ***
Accuracy up to 10m (+/-) ± 2 mm
Display 2 line/1 mm/1/32 in
Display illumination Yes
Laser point at distance 6/30/60 mm (10/40/100 m)
Area Yes
Units setting (smallest units displayed) 0,000m, 0' 00'' 1/32, 0 in 1/32
Auto laser switch off 90 sec
Auto power switch off 180 sec
General
Laser class II
Laser type 635 nm, <1 mW
Protection class IP54
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements
Size (Hx W x D) 11.9 x 3.8 x 2.6 cm
Drop test 1 meter
Weight (with batteries) 95g (3.35 oz)
Temperature range: Storage -25 °C to 70 °C (-13 °F to 158 °F)
Temperature range: Operation -10 °C to 50 °C (14 °F to 122 °F)
Calibration cycle Not applicable
Maximum relative humidity 85 % @ 20°F to 120 °F
(-7 °C to 50 °C)
Safety CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
EMC 61326-1:2006
- Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).
- Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to +122 °F).
- Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).
- Applies for 100 % target reflectivity, background illumination between 10,000 lux and 30,000 lux.
- After user calibration. Additional angle related deviation of ± 0.01° per degree up to ± 45° in each quadrant. Applies at room temperature. For the whole operating temperatur range the maximum deviation increases by ± 0.1
- Instantly measure up to 40 m (131 ft.) with 1-button point-and-click
- Continuous measurement capable: adjusting as you move closer and farther from your target
- Quickly calculate area (sq feet/meters)
- 1-meter drop tested and IP54 rated: built to withstand rainy or dusty conditions
- Great for interior and exterior applications
Product overview: Fluke 417D Laser Distance Meter
The Fluke 417D is accurate, durable, and easy to use—just point and shoot. The simple design and easy, one-button measurement operation allows you to minimize time spent measuring and maximize the reliability of measurements.
Additional Product Features:
Large, 2-line illuminated LCD screen.
Three different measurement tasks can be completed quickly and easily with one hand.
The bright laser is clearly visible, so you can always see your target point even from a hard-to-reach spot or long distance.
Designed for both indoor and outdoor applications.
Operates with the Fluke durability and quality you expect.
Protected by a 3-year warranty.
Specifications:
Typical range [1] 0.2-40 m/0.6-131 ft
Typical measuring tolerance* [1] 2.0 mm ± 1.5 mm/± 0.06 in ***
Maximum measuring tolerance [2] ± 3.0 mm/0.12 in ***
Accuracy up to 10m (+/-) ± 2 mm
Display 2 line/1 mm/1/32 in
Display illumination Yes
Laser point at distance 6/30/60 mm (10/40/100 m)
Area Yes
Units setting (smallest units displayed) 0,000m, 0' 00'' 1/32, 0 in 1/32
Auto laser switch off 90 sec
Auto power switch off 180 sec
General
Laser class II
Laser type 635 nm, <1 mW
Protection class IP54
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements
Size (Hx W x D) 11.9 x 3.8 x 2.6 cm
Drop test 1 meter
Weight (with batteries) 95g (3.35 oz)
Temperature range: Storage -25 °C to 70 °C (-13 °F to 158 °F)
Temperature range: Operation -10 °C to 50 °C (14 °F to 122 °F)
Calibration cycle Not applicable
Maximum relative humidity 85 % @ 20°F to 120 °F
(-7 °C to 50 °C)
Safety CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
EMC 61326-1:2006
- Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).
- Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to +122 °F).
- Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).
- Applies for 100 % target reflectivity, background illumination between 10,000 lux and 30,000 lux.
- After user calibration. Additional angle related deviation of ± 0.01° per degree up to ± 45° in each quadrant. Applies at room temperature. For the whole operating temperatur range the maximum deviation increases by ± 0.1