Model: KEW 1012

TRUE RMS DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DUTY DATAHOLD MAX/MIN Relative AutoPowerOff
  • True RMS can measure and indicate distorted waveforms
  • 6040 counts with Bar Graph display
  • MIN/MAX function enables to record min & max value
  • REL(relative value) function to indicate the measurement variation
DC V 600.0mV/6.000/60.00/600.0/600V
(Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V)
AC V 6.000/60.00/600.0/600V
(Input Impedance: 10MΩ) ±1.5%±5dgt
(6.000V) ±1.2%±3dgt (60.00/600.0V) ±1.5%±5dgt (600V)
DC A 600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A)
AC A 600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A)
Ω 600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt
(600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ)
Continuity buzzer 0 - 600Ω (Buzzer sounds below 100Ω)
Diode test 2.8V Release Voltage:Approx. 0.4mA Test Current
Capacitance 40/400nF/4/40/400/4000µF
Frequency 10/100/1000Hz/10/100/1000kHz/10MHz
DUTY 0.1 - 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz)
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-1 CAT II 600V Pollution degree 2
IEC 61010-031
IEC 61326
Display 6040 Counts
Power source R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes)
Dimensions 161(L) × 82(W) × 50(D)mm
Weight Approx. 280g
Included Accessories 7066A (Test leads)
0.8A/600V (Ceramic Fuse) × 1built-in
10A/600V (Ceramic Fuse) × 1built-in
R6 × 2
Instruction Manual
Optional Accessories 7234 (Crocodile clip test lead)
9095 (Carrying case)