KYORITSU KE 5410 RCD Tester (KEW 5410)
Regular price
RM3,280.00 MYR
Regular price
-30%
RM4,700.00 MYR
Sale price
RM3,280.00 MYR
Couldn't load pickup availability
•Why Buy From Us?
1) Trusted Seller - We are Shopee Preferred Seller and Local Seller (Based in Ampang, Selangor)
2) Safe Packing
3) We have physical stock, you can walk in. We are company, not personal seller home based.
4) All order is shipped together with our company official invoice
Can't wait for tomorrow? same day delivery can be arrange for Klang Valley customers!
Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
•
Measurement of trip out current
Measuring trip out current by varying current automatically.
•
Remote Test
Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
•
Voltage Measurement
Carrying out a constant measurement of voltage in the stand-by mode at each Range.
•
Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
•
Dust- and Water-proof
Dust- and Water-proof construction (designed to IEC 60529 IP54).
•
Backlight
Facilitating working at dimly illuminated locations.
Measurement of RCD trip time - Measurement of trip out current
Range
×5
×1
×1/2
AUTO RAMP (mA)
Rated Voltage
100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current
15/30/50/100mA
15/30/50/100/200/500mA
15/30/50/100/200/500mA
Measuring range
Testing time
200ms
Testing time
2000ms
Testing time
2000ms
40%~110% of lΔn
(goes up by 5%)
Testing time
300ms × 15steps
Accuracy
(Trip Time)
|±1%rdg±3dgt
|±1%rdg±3dgt
|±1%rdg±3dgt
Test Current
at each step
-4%~+4%
Accuracy
(Test Current)
|+2%~+8%dgt
|+2%~+8%dgt
|-8%~-2%dgt
Voltage Measurement
Measuring range
80V~450V (50/60Hz)
Accuracy
|±2%rdg±4dgt
Applicable Standard
IEC 61010-1 Pollution degree2 CAT.III 300V / CAT.II 400V
IEC 61010-031
IEC 61557-1, 6
IEC 60529 (IP54)
Display
1999 counts (3 1/2digits), Large LCD
Operating temperature & humidity
0ºC~40ºC, relative humidity 85% (no condensation)
Storage temperature & humidity
-20ºC~60ºC, relative humidity 85% (no condensation)
Withstand Voltage
AC3700V / 1 min. (between electrical circuit and enclosure)
Insulation resistance
50MΩ or more / 1000V (between electrical circuit and enclosure)
Sleep Function
(1)
Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2)
Backlight turns off in 1 minute after it lights up.
Power Source
DC 12V / Size AA battery R6P (SUM-3) × 8 pcs.
Dimension
186(L)×167(W)×89(D)mm
Weight
Approx. 965g (including batt
1) Trusted Seller - We are Shopee Preferred Seller and Local Seller (Based in Ampang, Selangor)
2) Safe Packing
3) We have physical stock, you can walk in. We are company, not personal seller home based.
4) All order is shipped together with our company official invoice
Can't wait for tomorrow? same day delivery can be arrange for Klang Valley customers!
Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
•
Measurement of trip out current
Measuring trip out current by varying current automatically.
•
Remote Test
Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
•
Voltage Measurement
Carrying out a constant measurement of voltage in the stand-by mode at each Range.
•
Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
•
Dust- and Water-proof
Dust- and Water-proof construction (designed to IEC 60529 IP54).
•
Backlight
Facilitating working at dimly illuminated locations.
Measurement of RCD trip time - Measurement of trip out current
Range
×5
×1
×1/2
AUTO RAMP (mA)
Rated Voltage
100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current
15/30/50/100mA
15/30/50/100/200/500mA
15/30/50/100/200/500mA
Measuring range
Testing time
200ms
Testing time
2000ms
Testing time
2000ms
40%~110% of lΔn
(goes up by 5%)
Testing time
300ms × 15steps
Accuracy
(Trip Time)
|±1%rdg±3dgt
|±1%rdg±3dgt
|±1%rdg±3dgt
Test Current
at each step
-4%~+4%
Accuracy
(Test Current)
|+2%~+8%dgt
|+2%~+8%dgt
|-8%~-2%dgt
Voltage Measurement
Measuring range
80V~450V (50/60Hz)
Accuracy
|±2%rdg±4dgt
Applicable Standard
IEC 61010-1 Pollution degree2 CAT.III 300V / CAT.II 400V
IEC 61010-031
IEC 61557-1, 6
IEC 60529 (IP54)
Display
1999 counts (3 1/2digits), Large LCD
Operating temperature & humidity
0ºC~40ºC, relative humidity 85% (no condensation)
Storage temperature & humidity
-20ºC~60ºC, relative humidity 85% (no condensation)
Withstand Voltage
AC3700V / 1 min. (between electrical circuit and enclosure)
Insulation resistance
50MΩ or more / 1000V (between electrical circuit and enclosure)
Sleep Function
(1)
Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2)
Backlight turns off in 1 minute after it lights up.
Power Source
DC 12V / Size AA battery R6P (SUM-3) × 8 pcs.
Dimension
186(L)×167(W)×89(D)mm
Weight
Approx. 965g (including batt