KYORITSU 5410 RCD Tester (KEW5410)
Couldn't load pickup availability
Got questions?
Feel free to WhatsApp us
Product Brochure
Click Here: Brochure in PDF
Product Datasheet / User Manual
Click Here: Datasheet in PDF
KEW 5410
Measurement of RCD Trip Time:
Conduct tests for rated residual non-operating currents at
half the range, and measure RCD trip times at one and five times the range.
- Measurement of Trip Out Current:
Measure trip out current by automatically varying the current.
- Remote Test:
Allow a user to hold the Test Leads in both hands
by locking the Test Button. Measurement will automatically
begin when the main voltage is detected.
- Voltage Measurement:
Perform continuous voltage measurements in
stand-by mode at each range.
- Auto-detection of Contact Voltage:
Detect earth electrode or protective conductor voltage to ground during RCD testing—when applying
test currents—at measurements using EARTH to
prevent electrical shocks from a damaged earth.
Measurement will stop if AC50V or higher is detected.
- Dust- and Water-proof:
The construction is dust- and water-proof,
designed according to IEC 60529 IP54 standards.
- Backlight:
Provides illumination for working in poorly lit areas.
Measurement of RCD trip time - Measurement of trip out current
Range | × 5 | × 1 | × 1/2 | AUTO RAMP(mA) |
---|---|---|---|---|
Rated Voltage | 100V±10% 200V-10%~+32% 400V±10% 50/60Hz |
|||
Test current | 15/30/50/100mA | 15/30/50/100/200/500mA | 15/30/50/100/200/500mA | |
Measuring range | Testing time 0ms~200ms |
Testing time 0ms~2000ms |
Testing time 0ms~2000ms |
40% - 110% of lΔn (goes up by 5%) Testing time 300ms × 15steps |
Accuracy (Trip Time) |
1%rdg±3dgt | 1%rdg±3dgt | 1%rdg±3dgt | Test Current at each step -4%~+4% |
Accuracy |
+2%~+8%dgt | +2%~+8%dgt | -8%~-2%dgt |
Voltage Measurement
Measuring range | 80V~450V 50/60Hz |
---|---|
Accuracy | 2%rdg±4dgt |
Applicable standards | IEC 61010-1 Pollution degree2 CAT III 300V / CAT II 400V IEC 61010-031 IEC 61557-1, 6 IEC 60529 (IP54) |
---|---|
Display | 1999 counts (3 1/2digits), Large LCD |
Operating temperature & humidity range | 0ºC - 40ºC, relative humidity 85% (no condensation) |
Storage temperature & humidity range | -20ºC - 60ºC, relative humidity 85% (no condensation) |
Insulation resistance | 50MΩ or more / 1000V (between electrical circuit and enclosure) |
Sleep Function | (1)Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted. (2) Backlight turns off in 1 minute after it lights up. |
Power source | DC 12V / R6(AA)(1.5V) × 8 |
Dimension | 167(L)×186(W)×89(D)mm |
Weight | Approx. 965g (including batteries) |
Possible number of Measurements | 1200 times or more (measure every 30 seconds at ×1/2 Range, lΔn=100mA) |
Included Accessories | 7128A (Test leads) 7129A (Test lead with alligator clip) 8017 (Extension prod) × 2 9121 (Shoulder strap) 9147 (Cord case) Instruction manual, R6(AA) × 8 |