The Fluke 971 Temperature Humidity Meter is a compact handheld digital hygrometer and thermometer that gives you fast, accurate readings of air temperature and relative humidity in one instrument. Alongside ambient temperature and % RH it calculates dew point and wet bulb temperatures at the press of a button, so HVAC technicians, facility managers and indoor air quality (IAQ) specialists can check comfort conditions, verify air-conditioning performance and spot condensation and mould risk without carrying extra probes or charts.
Key Features & Benefits
- Four readings in one meter – relative humidity, ambient temperature, dew point (-50°C to 60°C) and wet bulb (-20°C to 60°C).
- Backlit dual display – humidity and temperature shown together, readable in plant rooms and ceiling voids.
- Accurate sensing – ±0.5°C (0°C to 45°C) and ±2.5% RH (10% to 90% RH) with 0.1° and 0.1% RH resolution.
- Quick-response capacitance sensor with a protective cover.
- 99-point memory – each saved point stores % RH plus ambient, dew point and wet bulb temperatures for later recall.
- Min / Max / Avg recording and Data Hold – capture extremes over a survey or freeze a reading to note it down.
- Long battery life – up to 200 hours on 4 AAA batteries, with low-battery indicator and switchable 20-minute auto power-off.
- Built for the field – compact 190g body, belt clip and protective holster.
Technical Specifications
| Specification | Value |
|---|---|
| Temperature range | -20°C to 60°C (-4°F to 140°F) |
| Temperature accuracy | ±0.5°C (0°C to 45°C); ±1.0°C (-20°C to 0°C and 45°C to 60°C) |
| Temperature resolution | 0.1°C / 0.1°F |
| Temperature update rate | 500ms |
| Temperature sensor | NTC |
| Relative humidity range | 5% to 95% RH |
| Relative humidity accuracy (at 23°C) | ±2.5% RH (10% to 90% RH); ±5.0% RH (<10% and >90% RH) |
| Relative humidity resolution | 0.1% RH |
| Humidity response time | 60 s for 90% of total range with 1 m/s air movement |
| Humidity sensor hysteresis | ±1% RH (10% to 90% to 10% RH excursion) |
| Temperature coefficient | 0.1 × specified accuracy per °C (0°C to 18°C and 28°C to 50°C) |
| Humidity sensor | Electronic capacitance polymer film |
| Dew point range | -50°C to 60°C (-58°F to 140°F) |
| Wet bulb range | -20°C to 60°C (-4°F to 140°F) |
| Data storage | 99 points (oldest overwritten first when full) |
| Operating temperature | Temperature: -20°C to 60°C (-4°F to 140°F); Humidity: 0°C to 55°C (32°F to 131°F) |
| Storage temperature | -20°C to 60°C at <80% RH (batteries removed) |
| Altitude | Up to 2000m |
| Environment | Indoor use only |
| Power | 4 × 1.5V AAA alkaline (LR03 / 24A) |
| Battery life | 200 hours |
| Auto power-off | After 20 minutes of no activity (can be disabled) |
| Dimensions (H × W × D) | 194 × 60 × 34mm (7.6 × 2.4 × 1.3 in) |
| Weight | 190g (6.7 oz) with batteries |
| Fluke part number | 2418208 |
| Country of origin | Made in Taiwan |
Safety & Compliance
- Electromagnetic compatibility: EN 61326-1
- Meets European (CE), Canadian (CSA) and Australian requirements
What's in the Box
- Fluke 971 Temperature Humidity Meter
- 4 × AAA alkaline batteries
- Operation manual
Optional Accessories
Compatible accessories listed by Fluke, sold separately and available on request:
- Fluke C1600 – tool hard case
- Fluke LVD1A – non-contact voltage tester with LED flashlight
Applications
- HVAC commissioning and service – supply/return air checks, temperature split and humidity removal across a coil
- Indoor air quality and comfort surveys in offices, schools, hospitals and hotels
- Condensation and mould-risk checks using dew point on walls, ducts and chilled-water pipework
- Data centre, server room and clean-room environmental spot checks
- Cold rooms, commercial kitchens and food storage areas
- Paint booths, coating and curing areas where temperature and humidity limits apply
- Warehouses and stores holding humidity-sensitive goods
Using the Fluke 971
- Let it settle – when moving between very different conditions (e.g. from a cold room to a hot plant room), give the meter time to stabilise before taking a reading.
- Saving and recalling – press Save to store the present readings; press Recall and use the ▲ / ▼ arrows to step through memory locations. Hold Recall for two seconds to return to normal operation.
- Clearing memory – press and hold Save and Recall together for five seconds to erase all 99 locations.
- Min / Max / Avg – choose ambient, dew point or wet bulb first, then press Min/Max to step through the stored minimum, maximum and average. Hold the button for two seconds to exit. While recording, the °C/°F switch, Save, Recall, Hold and auto power-off are disabled.
- Settings switches – the °C/°F switch and the auto power-off switch are inside the battery compartment; the battery door is held by a single screw.
- Care – wipe the case with a damp cloth and mild detergent or Fluke meter cleaner. Do not use abrasives or solvents.
Complete Your HVAC Toolkit
Fluke 922 Airflow Meter Kit | Fluke 62 MAX+ Infrared Thermometer | Fluke 54 II B Data Logging Thermometer
| Warranty period | 1 Year Warranty |
|---|---|
| Coverage | Free from defects in material and workmanship for 1 year from the date of purchase, including accessories supplied with the product, such as test leads and probes. |
| Not covered | Fuses, disposable batteries and manuals; damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. For Fluke Networks products, parts and accessories (including rechargeable batteries and cables) are covered for 90 days. |
| Warranty void if | The product has been used outside its specifications, altered, or repaired by a party not authorised by Fluke. |
Contact Techno Tools with your proof of purchase. The warranty applies to the original purchaser only.
Frequently Asked Questions
How do I switch the Fluke 971 between °C and °F?
Does the Fluke 971 need an external probe?
How do I see dew point and wet bulb on the Fluke 971?
What happens when the 99 memory locations are full?
The humidity reading seems off. What can cause this?
Can I use the Fluke 971 outdoors?
Is a calibrated version of the Fluke 971 available?
Order by 4PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on time.
Free delivery for total orders above RM500, otherwise additional charges costs are calculated at checkout based on your order’s weight and delivery location.
Further details please click here for more info.
Please notify us within 14 calendar days of receiving your product to request a free exchange or full refund, if eligible. We will cover all return shipping costs, and no restocking fees will apply in this case.
Requests made after 14 days may be accepted at our discretion and will be subject to a 10% restocking fee. Techno Tools & Equipment reserves the right to reject any return request found to be ineligible.
Further details please click here for more info.