FLUKE 1630-2 Earth Tester, 1.5kΩ CAT III 1000 V, CAT IV 600 V (FK 1630-2)

In stock
SKU: FK 1630-2
Regular price RM15,390.00 MYR

Product Brochure

Click Here: Brochure in PDF

Product Datasheet / User Manual

Click Here: Datasheet in PDF

Trustify review stars will be displayed here!

Product Details

FLUKE Earth Tester, LCD Screen, Battery Powered - FLUKE-1630-2


No place to stake your earthing clamp? Eliminate the problem with this stakeless earth tester from FLUKE. Its dual-clamp jaw makes it a snap to measure earth ground loop resistances indoors or in paved areas, without having to search for a suitable staking spot. It also removes the need for disconnecting parallel ground loops, so minimises the chance of electric shocks giving you a jolt. The tool is designed to stay aligned and calibrated, which cuts out the risk of incorrect readings. As it automatically records data at preset intervals, you don't have to worry about manually saving your information.

Features & Benefits


• Large memory capable of storing more than 32,000 measurements
• Band-pass filter removes noise, for accurate AC leakage current detection
• Easy-to-read LCD screen means you can see data in most light conditions
• IP30-rated when its jaw is closed so protected against tools and wires larger than 2.5mm

Applications


• Electrical installation
• Safety systems
• Construction industry

How heavy is this earth tester?


With a light weight of just 880g, this tool is easy to handle and carry with you on the job.


Specifications

Attribute
Value
Absolute Maximum Resistance Measurement 1.5kΩ
Best Accuracy ±1.5 % of 0.02 Reading
Display Type LCD
Measurement Type Earth Ground Loop Resistance
Safety Category CAT III 1000 V, CAT IV 600 V
Battery Life 15 h
Battery Type AA
Power Source Battery
Dimensions 283 x 105 x 48mm
Weight 880g
Height 283mm
Includes 4 AA Batteries, Earth Ground Clamp, Hard Case, Loop Resistance Standard, Quick Reference Guide, Safety Information Guide
Length 105mm
Maximum Operating Temperature +50°C
Width 48mm
Safety Category Level CAT III, CAT IV
Model Number p 1630-2
Safety Category Voltage 600 V, 1000 V
Minimum Operating Temperature -10°C