KYORITSU KE 2413R Leakage Digital Clamp Meter (KEW 2413R)
Regular price
RM2,395.00 MYR
Regular price
-33%
RM3,600.00 MYR
Sale price
RM2,395.00 MYR
Couldn't load pickup availability
Why Buy From Us?
1) Trusted Seller - We are Shopee Preferred Seller and Local Seller (Based in Ampang, Selangor)
2) Safe Packing
3) We have physical stock, you can walk in. We are company, not personal seller home based.
4) All order is shipped together with our company official invoice
Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
•
True RMS enables an accurate measurement for distorted waveforms.
•
Measurement from mA up to
AC 1000A
Frequency filter switch to eliminate the effect of the harmonics.
•2 way analogue output terminal:
AC current detected by transformer jaws is converted to AC and DC voltage. Output cord model 7073 (option) is used for monitoring waveform with an oscilloscope or for connecting to a recorder.
AC A
(50/60Hz)
200mA/2/20/200/1000A
|±2.5%rdg±5dgt (200mA/2/20A)
|±3.0%rdg±5dgt (200A, 0~500A)
|±5.5%rdg (501~1000A)
AC A
(WIDE)
200mA/2/20/200/1000A
|±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A)
|±2.0%rdg±5dgt (50/60Hz) (200A, 0~500A)
|±5.0%rdg (50/60Hz) (501~1000A)
Conductor Size
Ø68mm max.
Frequency Response
40Hz~1kHz
Output
Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Crest Factor
3.0 or less
Withstand Voltage
3700V AC for 1 minute
Applicable Standard
IEC 61010-1 CAT.III 300V Pollution degree 2
IEC 61010-2-032
Power Source
6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours
Dimensions
250(L) × 130(W) × 50(D)mm
Weight
Approx. 570g (including battery)
Accessories
9094 (Carrying Case)
6F22 × 1
Instruction Manual
Optional
7073 (2WAY Output Cord)
Made in: Japan
1) Trusted Seller - We are Shopee Preferred Seller and Local Seller (Based in Ampang, Selangor)
2) Safe Packing
3) We have physical stock, you can walk in. We are company, not personal seller home based.
4) All order is shipped together with our company official invoice
Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
•
True RMS enables an accurate measurement for distorted waveforms.
•
Measurement from mA up to
AC 1000A
Frequency filter switch to eliminate the effect of the harmonics.
•2 way analogue output terminal:
AC current detected by transformer jaws is converted to AC and DC voltage. Output cord model 7073 (option) is used for monitoring waveform with an oscilloscope or for connecting to a recorder.
AC A
(50/60Hz)
200mA/2/20/200/1000A
|±2.5%rdg±5dgt (200mA/2/20A)
|±3.0%rdg±5dgt (200A, 0~500A)
|±5.5%rdg (501~1000A)
AC A
(WIDE)
200mA/2/20/200/1000A
|±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A)
|±2.0%rdg±5dgt (50/60Hz) (200A, 0~500A)
|±5.0%rdg (50/60Hz) (501~1000A)
Conductor Size
Ø68mm max.
Frequency Response
40Hz~1kHz
Output
Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Crest Factor
3.0 or less
Withstand Voltage
3700V AC for 1 minute
Applicable Standard
IEC 61010-1 CAT.III 300V Pollution degree 2
IEC 61010-2-032
Power Source
6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours
Dimensions
250(L) × 130(W) × 50(D)mm
Weight
Approx. 570g (including battery)
Accessories
9094 (Carrying Case)
6F22 × 1
Instruction Manual
Optional
7073 (2WAY Output Cord)